User Manual New Wave Needle-Free Electro-Mesotherapy...
Page 2
Information furnished by Viora is believed to be accurate and reliable. However, Viora assumes no responsibility for its use. No license is granted by its implication or otherwise under any patent or patent rights of Viora.
Infusion™ Solutions All natural, Infusion™ solutions are created from the purest, high quality clinically proven ingredients. Each solution is a blend of special serums, proteins and healing agents and is precisely formulated for a specific application. Using only the most sterile ingredients, Infusion™...
Page 5
Viora’s Ionic Solutions, together with Ionwave’s™ electro chemical manipulation of cell channels, affect skin at the cellular level. Scientifically engineered to achieve the desired effect, the interplay between these two modalities determines the penetrations depth and ensures sufficient permeability. To achieve optimal results, Infusion™ Electro-mesotherapy employs the combination of: •...
Results also depend on the clinical and physiological condition of the skin at the start of the treatment course. Some patients will respond better than others. Infusion™ can be used either alone or in combination with other aesthetic treatments in a variety of clinical applications.
Page 7
System Labels System Classifications • Electric shock protection: Class I, Type BF • Not suitable for use in presence of flammable substances • Protection against ingress of liquids: Ordinary equipment • Operation mode – continuous EMC - Electromagnetic Compatability Table 1– Guidance and Manufacture’s declaration – ELECTROMAGNETIC EMISSIONS – for all ME EQUIPMENT and ME SYSTEMS...
Page 8
Guidance and manufacturer’s declaration – electromagnetic emissions The Infusion is intended for use in the electromagnetic environment specified below. The customer or the user of the Infusion should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –...
Page 9
Guidance and manufacturer’s declaration – electromagnetic immunity The Infusion is intended for use in the electromagnetic environment specified below. The customer or the user of the Infusion should assure that it is used in such an environment. IMMUNITY test IEC 60601 test level...
Page 10
EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacturer’s declaration – electromagnetic immunity The Infusion is intended for use in the electromagnetic environment specified below. The customer or the user of the Infusion should assure that it is used in such an environment. IMMUNITY test...
Page 11
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Infusion is used exceeds the applicable RF compliance level above, the Infusion should be observed to verify normal operation.
Page 12
ME SYSTEM] The Infusion is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Infusion can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the...
Other cables and accessories may affect EMC performance 2. Safety Instructions Infusion™ Applications Be sure to read and understand all instructions before using the Infusion™ Electro- mesotherapy system. Failure to follow the guidelines in this manual may result in personal injuries or damage to your equipment.
Page 14
To ensure safety and reliability, always use this system in accordance with the proper operating and maintenance procedures. Viora assumes no liability whatsoever for any damage or injury that may result from the misuse of this device. Always observe the following safety guidelines when operating the Infusion™...
• Compare the contents of the box to the equipment list (see Box Contents section below) to ensure that all accessories are present. • Lift the Infusion™ unit up and out of the bottom Styrofoam brace and carefully set it on a table or counter.
8. Hand piece connectors 4. Clinical Guide Indications The Infusion™ Electro-mesotherapy system, along with Viora’s solutions, is designed to target a wide range of skin conditions including: • Temporary reduction in the appearance of cellulite • Temporary reduction of local fat •...
Contraindications The following conditions are contraindicated with the Infusion™ treatment: • Patients with pacemaker or internal defibrillator • Metal or other implants in the treatment area • Immune system disorders. Consult with a doctor • Epilepsy • Pregnancy • Botox injection or another type of collagen injection treatment within the last 15 days.
Treatment course should begin only after a test procedure has been performed successfully and no adverse effects were recorded. General Treatment Guidelines Viora strongly recommends the use of sanitary gloves. Immediately prior to treatment it is recommended to: • Clean the skin with a hypoallergenic skin cleanser.
• Ask for patient feedback during treatment. The patient should feel a tingly sensation that is not overbearing. • Treatment intensity settings may be moved up or down anytime during treatment. Caution • Be cautious when using treatment intensity higher than 70% when treating the face.
Body Treatment 1. On the main menu display, select "Body". 2. Select treatment intensity level using the treatment intensity dial. 3. Open one ampoule of treatment solution and pour it out into a small bowl. Apply the solution to the treatment area. Reapply the solution as necessary throughout the treatment.
Page 21
5. Remove the body hand piece from its cradle and gently apply circular motions over the entire treatment area (see Illustrations D, E, F and G). 6. Slowly increase power intensity according to the patient’s comfort level. 7. Clean and dry the hand piece before returning it to its holder (refer to Section 6.1. Cleaning the Device).
The number of required treatment sessions varies from patient to patient and will depend on the clinical and physiological condition of the skin at the start of the treatment course. Viora recommends sessions of 6-8 treatments in 7-10 day intervals. Please note that some patients respond better than others.
Troubleshooting The following steps offer a list of corrective actions in case of system malfunction. You may find that a system error can be cleared by restarting the Infusion™ system. Always try this option before contacting your distributor. If the system does not start: A.
5 kgs /11 lbs 8. Infusion Warranty Limited Warranty Infusion™ is under warranty according to the purchase terms agreed upon with your local dealer. For warranty terms, conditions and further information, please contact your local dealer. Except as provided herein, the manufacturer makes no warranties, expressed or implied,...
Page 26
About Viora Viora is a market leader in the development of technologically advanced medical aesthetics systems for physicians and aesthetic clinicians worldwide. Dedicated to the research and development of safe and effective aesthetic solutions, Viora provides the highest standard of professional grade solutions while keeping your business in mind.