AccuTools TruBlu User Instructions page 6

Evacuation tools, steps to a proper evacuation
Table of Contents

Advertisement

Low Profile Stainless Clamp (left)
Clamp Assembly
Standard Aluminum (right)
When connecting the TruBlu hoses to the equipment, ensure that you relieve all the pressure on the system.
Removing the Schrader cores provide the fastest evacuation. The 1/4" hose-end is to be connected directly to
the back of the AccuTools Schrader Core Removal Tool. *If the cores cannot be removed, connect the AccuTools
Schrader Core Depressor to the service valve, and depress the core with the thumb screw to fully open the
Schrader port. Removing the cores significantly decreases the evacuation time, and the core tool can be used to
reinsert the core even after the system refrigerant charge as been released and the system is under pressure.
Vacuum and Pressure Rated Valve
Vacuum and Pressure Rated
Core Removal Tool
Schrader Core Depressor
Core Tool with Vacuum Gauge
Core Tool with Vacuum Gauge Installed on Side
Installed on Side Port
Port and Schrader Core Depressor/Angle Valve
6