Cooper Power Systems VCS-1SX Installation And Operation Instructions Manual

Vacuum solenoid-operated capacitor switch

Advertisement

Quick Links

Vacuum Switches
Type VCS-1SX
Solenoid-Operated Capacitor Switch
Installation and Operation Instructions
Figure 1.
Kyle
®
Type VCS-1SX Single-Phase Vacuum Capacitor Switch.
Contents
Safety Information........................................................ 2
Hazard Statement Definitions ...................................... 2
Safety Instructions ....................................................... 2
Product Information..................................................... 3
Introduction .................................................................. 3
Acceptance and Initial Inspection ................................ 3
Handling and Storage .................................................. 3
Description of Operation .............................................. 3
Ratings and Specifications ........................................ 4
Dimensions....................................................................5
June 2000 • Supersedes March 2000
Printed in USA
S260-15-3
Installation Procedure .................................................6
High-Voltage Connections .......................................... 6
Control Wiring ............................................................. 6
Wiring Diagrams ......................................................... 7
Service Information ..................................................... 8
Service Requirements ................................................. 8
Frequency of Inspection .............................................. 8
High Potential Withstand Tests ................................... 8
Factory Authorized Service Centers ........................... 8
Service Information
99029KM
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VCS-1SX and is the answer not in the manual?

Questions and answers

Summary of Contents for Cooper Power Systems VCS-1SX

  • Page 1 Solenoid-Operated Capacitor Switch S260-15-3 Installation and Operation Instructions Figure 1. 99029KM Kyle ® Type VCS-1SX Single-Phase Vacuum Capacitor Switch. Contents Safety Information............2 Installation Procedure ..........6 Hazard Statement Definitions ........2 High-Voltage Connections .......... 6 Safety Instructions ............2 Control Wiring ............. 6 Product Information.............
  • Page 2: Safety Information

    Type VCS-1SX Solenoid-Operated Capacitor Switch Installation and Operation Instructions SAFETY SAFETY SAFETY FOR LIFE FOR LIFE FOR LIFE Kyle Distribution Switchgear products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Kyle employees involved in product design, manufacture, marketing, and service.
  • Page 3: Product Information

    Information, Ratings and Specifications, Dimensions, The VCS-1SX switch has a single, solid polymer bushing Installation Procedure, and Service Information . Refer to and is suitable for operation through a temperature range the table of contents for page numbers.
  • Page 4: Ratings And Specifications

    Type VCS-1SX Solenoid-Operated Capacitor Switch Installation and Operation Instructions RATINGS AND SPECIFICATIONS Check Switch Ratings TABLE 5 Current Ratings Before Installation The switch must be applied within its specified ratings. Rated Asymmetrical Making Current ... 9000 A Check data plate ratings and compare with the system Rated Continuous Current .
  • Page 5: Dimensions

    CLOSED RECEPTACLE MOUNTING HOLE FOR (2.05) 31.75 16 (0.625) BOLT (1.25) (2.75) (8.07) 35 (1.38) Ø 31.75 (1.25) (4.72) (4.96) (7.12) 146.6 (5.77) Note: All dimensions shown in mm (in). (8.38) Dimensions are approximate. Figure 2. Dimensions of VCS-1SX switch.
  • Page 6: Installation Procedure

    Type VCS-1SX Solenoid-Operated Capacitor Switch Installation and Operation Instructions INSTALLATION PROCEDURE Check-out Procedure 1. Ground the switch. Make the ground connection to the ground connector located on the switch as shown 1. Check data plate. Make sure that ratings on the data in Figure 2.
  • Page 7: Wiring Diagrams

    S260-15-3 SAFETY FOR LIFE Wiring Diagrams Schematic diagrams of switch actuators with various accessories wired for two- and three-wire control are shown in Figure 5. 5 Pin Three-wire Control Common Control Coil Interrupting Close Switch Voltage Close Coil Open Coil Interrupting Switch Open Coil...
  • Page 8: Service Information

    Type VCS-1SX Solenoid-Operated Capacitor Switch Installation and Operation Instructions SERVICE INFORMATION Service Requirements Open Contacts Test 1. Open the switch contacts. The Kyle Type VCS-1SX switch has been designed with a minimum mechanical life of 15,000 operations. The 2. Ground the switch.

Table of Contents