NANO-N
mA Input
Installation
Maintenance
Repair
Manual
ENTER
Advantage Controls
4700 Harold Abitz Dr.
Muskogee, OK 74402
Phone: 918-686-6211
Fax: 888-686-6212
www.advantagecontrols.com
4/2019
email: support@advantagecontrols.com
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NANO-N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Advantage Controls NANO-N

  • Page 1 Manual NANO-N mA Input Installation Maintenance Repair Manual ENTER Advantage Controls 4700 Harold Abitz Dr. Muskogee, OK 74402 Phone: 918-686-6211 Fax: 888-686-6212 www.advantagecontrols.com 4/2019 email: support@advantagecontrols.com...
  • Page 2: Table Of Contents

    Table of Contents Contents Page Introduction ................. 3 Description .................. 3 III. Installation Mounting Instructions ..............4 Electrical Wiring ................4 Relay Cards ................4 Logic Cards ................5 Front Panel Description .............. 6 System Operation Overview ............6 Description of Menus ..............6 Maintenance ................
  • Page 3: Introduction

    Y - ETL Listing / Approvals Description NANO-N units are designed to display a mA input and transmit a mA and/or pulse output. It also can provide an automated control of chemical feeds and other external devices via two control relay outputs.
  • Page 4: Installation Mounting Instructions

    6. The electrical installation of the controller must be performed by trained personnel only and conform to all applicable National, State and Local codes. 7. Operation of this product in a manner not specified by Advantage Controls may result in damage to equipment or persons.
  • Page 5: Logic Cards

    Relay Card for W Option Switch # Position Function Relays can be a dry contact by changing Backlight off; flashes on w/ alarm the jumpers and POWER SUPPLY connecting to Ground and either N.O. or N.C. Backlight on; flashes off w/ alarm Ribbon Normal Operation Cable...
  • Page 6: Front Panel Description

    Front Panel Description Press MENU to access menus or go back one layer in menu structure. MENU Wed 10:59:57am Press FORCE to activate relays manually again for Off and a third time back to auto. FORCE ON/OFF Press ENTER to go a layer deeper in menu, ENTER to initiate a setting change and to set change.
  • Page 7: Maintenance

    Maintenance The only required maintenance for normal uninterrupted operation of your controller is cleaning of the electrode(s). After initial start up, it is a good idea to clean the electrode frequently until a schedule based on need has been developed. Since each application is unique, it is difficult to estimate the required frequency of cleaning.
  • Page 8: Nanotron Ma Menu Map

    Calibration Control Set 4-20 Output Timer Set Password 0000 4mA applied: N Setpoint 500.0 4mA In: 04350 Pulse Run After 0100 4 mA = 000.0 Only shows Flow Sw: Close Diff 050.0 20mA= 999.9 if WM active Run Time mm:ss 20mA applied: N 20mA In: 21350 DigIn: W Meter...
  • Page 9: Viii. Nanotron Ma Menu Map

    Force Set Diagnostics Water Meter Clock Set 4-20 Output Pulse Output Only shows Force On: Both Nano-4-20 if WM active Set Time Password 0000 4 mA = 000.0 un After 0100 LoRate= 000.0 Reset Meter? N FW: ?.?.? Flow Sw: Close Set Date R1 Cntrl mm:ss 20mA= 999.9...
  • Page 10: Warranty & 30 Day Billing Memo Policy

    Manufacturer’s Product Warranty Advantage Controls warrants units of its manufacture to be free of defects in material or workmanship. Liability under this policy extends for 24 months from date of installation. Liability is limited to repair or replacement of any failed equipment or part proven defective in material or workmanship upon manufacturer’s examination.
  • Page 11 - Notes -...
  • Page 12 Get the Advantage in Water Treatment Equipment Advantage Controls can give you the Advantage in products, knowledge and support on all of your water treatment equipment needs.  Cooling Tower Controllers  Boiler Blow Down Controllers  Blow Down Valve Packages  Solenoid Valves...