General
The Interface Module XC
meters. The module is equipped with an M-Bus (2 wires) interface. The module can be plugged
easily into the module compartment of the meter. It can be mounted or exchanged during operation
(without breaking approval seal). An integrated M-Bus interface (Protocol Converter to DIN EN
13757-3) provides a simple means of connecting multi-energy meters. This makes multi-energy
applications an affordable proposition for domestic use. Due to the communication, the modules are
suitable for a lot of control centres.
Safety Notes
The owner of the interface modules is responsible that all persons engaged on
work with the modules:
• Are competent and qualified in accordance with national regulations (see ISSA
"Guideline for Assessing the Competence of Electrically Skilled Persons").
• Have read and understood the relevant sections of the user manual.
• Strictly observe the safety regulations (according to the following section) and
the instructions in the individual chapters.
The owner of the modules is also responsible for:
The protection of persons.
The prevention of material damage.
The training of personnel.
The following safety regulations must be observed at all times:
Devices which have fallen down should not be installed, even if no damage is apparent, and should
be returned for testing to an authorised service centre (internal damage possible).
Modules must never be cleaned with running water or high pressure devices. Water can cause
short-circuits or damage el. components.
Interface Module XC
Protocol Converter / User Manual
is designed for use with the EMH LZQJ-XC and DMTZ-XC
Compatible meters
LZQJ-XC (special meter for industrial applications):
- Standard meter for direct connection
- Transformer connection version Cl. B (Cl. 1)
- Precision meter Cl. C (Cl. 0.5S)
- Precision meter Cl. 0,2S
DMTZ-XC (residential meter)
Functions
M-Bus interface (2 wires, passive) for bi-directional
communications;
Alternative: BFC-Bus (BAER Field Control, 56VDC);
Transmission protocol: M-Bus (DIN EN 13757-3:2013-08);
Internal communication interface for the transfer data
between the meter and the interface module (service data
list / table TS);
Protocol converter for meter data into M-Bus-Format
(non transparent data readout);
Internal power supply from meter;
Exchangeable during the meter operation;
Page 1 from 12
E130506819092

Advertisement

loading

Summary of Contents for Baer Interface Module XC

  • Page 1 Page 1 from 12 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 General The Interface Module XC is designed for use with the EMH LZQJ-XC and DMTZ-XC meters.
  • Page 2 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Installation Hints The installation must be done in a way, that even in the case of cable break no dangerous voltages are applied to touchable parts of the module.
  • Page 3 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Communication (M-Bus, Protocol Converter) The M-Bus interface is conforming to DIN EN 13757-3:2013-08.
  • Page 4 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Service Data List / Table TS and M-Bus-Address For setting the meter data list use menu Lists ...
  • Page 5 Page 5 from 12 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Accepting the meter data (OBIS-Registers) The Interface Module XC reads the service data list / table (TS) from the meter periodically (interval between two readings: ca.
  • Page 6 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Other OBIS-Registers will not be stored and cannot be transmitted. *: possible since firmware version 5...
  • Page 7 Page 7 from 12 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Structure of a data telegram (RSP_UD) No. of Value...
  • Page 8 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Examples for read out with secondary address: Master: 68 0B 0B 68 53 FD 52 00 00 00 00 FF FF FF FF 9E 16 (selection with the...
  • Page 9 Page 9 from 12 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Technical data Housing: Polycarbonate housing with terminals for using with EMH LZQJ-XC and...
  • Page 10 Interface Module XC Page 10 from 12 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Dimensions...
  • Page 11 Interface Module XC Page 11 from 12 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Terminal assignment Terminal block: Terminal Description...
  • Page 12 Page 12 from 12 E130506819092 Protocol Converter / User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Baer Energie- & Messtechnik GmbH Siemensstr. 3 D-90766 Fürth...