Installation
The heater should not be connected until the instruction leaflet
has been read fully.
The installation should be carried out by a suitably qualified
electrician/engineer in accordance with applicable standards.
Remove all items from the packaging. The heater should be fixed
to the floor using the fixing points provided - see Fig. 3. Ensure
the heater is securely fastened.
449
Remove the terminal cover and connect the mains cable, while
making note of the path the connecting cable should take through
the guard.
Reattach the terminal cover to the heater and fasten the cable
gland.
Mount the guard over the heater. Ensure the guard is mounted
centrally relative to the heater as shown in Fig. 4.
199
579
625
Thermal Safety Cut-out
The thermal cut-out will operate and the power supply to the
heating element will be interrupted if ventilation of the heater is
impaired.
Before resetting the thermal cut-out, the cause of the impaired
ventilation should be established and eliminated.
Procedure for resetting cut-out
1. Disconnect power supply.
2. Remove the guard.
3. Remove the terminal cover to access the thermal cut-out
Fig. 2.
4. Press the reset tab located in the centre of the cut-out (cut-out
clicks when reset) - see 'x' in Fig. 2.
5. Re-fit the terminal cover and reconnect power supply.
6. Re-fit the guard.
If the cut-out continues to operate intermittently, the heater should
be switched off and a service agent contacted.
The product complies with the European Safety Standards EN60335:2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014:1,
EN55014:2, EN61000:3-2 and EN61000:3-3 which cover the essential requirements of EMC Directive 2014/30/EU and the LVD Directive 2014/35/EU.
[c] GDC Group Ltd.
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of GDC Group Ltd.
179
407
608
Cleaning and User Maintenance
WARNING: DISCONNECT SUPPLY before carrying out
maintenance.
The heater should be subject to a regular maintenance schedule
with the following actions as a minimum:
·
Check that the heater surfaces are clean and free from any
deposits. The heater can be cleaned by wiping with a damp
cloth. Neither abrasive cleaning powders nor furniture polish
should be used.
·
The internal wiring shall be clean and dry, with no apparent
deterioration of the wiring insulation.
·
All connections shall be tight, without signs of overheating.
Recycling
Fig. 3

After Sales Service

Your product is guaranteed for one year from the date of purchase.
After sales information or assistance with this product can be
found on our website:
www.dimplex.co.uk/support.
Your rights under this guarantee are additional to your statutory
rights, which in turn are not affected by this guarantee.
Please do not return a faulty product to us as this may result in loss
or damage and delay in providing you with a satisfactory service.
If after following these steps your product still does not operate
you should return it to your point of purchase.
Please retain your receipt as proof of purchase.
255
Fig. 4
- see
For electrical products sold within the European
Community. At the end of the electrical products
useful life it should not be disposed of with
household waste.
Please recycle where facilities exist. Check
with your Local Authority or retailer for recycling
advice in your country.

Advertisement

loading