KLASCHKA BDK-1.3 Technical Data Manual

Double sheet metal monitor

Advertisement

BDK-1.3 Double Sheet Metal Monitor
Device Description GB 20.05-80, -81, -82, -93, 20.21-01
Edition 5.17
____________________________________________________________________________________________
Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
____________________________________________________________________________________________
Klaschka Industrieelektronik GmbH
Am Zeller Pfad 1
75242 Neuhausen
Germany
Fon +49 7234 79-0
Fax +49 7234 79-112
e-mail: sales@klaschka.de
www.klaschka.de
1
1
1
2
3
8
11
13
14
15
16
16
23
24
25
26
27
28
29

Advertisement

Table of Contents
loading

Summary of Contents for KLASCHKA BDK-1.3

  • Page 1: Table Of Contents

    BDK-1.3 Double Sheet Metal Monitor Device Description GB 20.05-80, -81, -82, -93, 20.21-01 Edition 5.17 ____________________________________________________________________________________________ Contents Application Configuration Mode of Operation Versions Operation Interfaces Pulse Diagram for Interrogation of Measured Value Interconnection with Press Controller Wiring 10. Wiring Diagrams 11.
  • Page 3: Application

    (initiator) and the 0-, 1- and 2- the down- and uploading of all program parameters. sheet detection. KLASCHKA GB 5.17 1/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 4: Versions

    (The measured thickness will appear to be greater than the actual thickness). 2/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 5: Operation

    "+" (9) and "-" (10) keys (see picture in chapter 5.5). sheet message. KLASCHKA GB 5.17 3/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 6 - Lead length and cross section (at DSP, DSPW). - Air gap between sensor and workpiece (single surface measurement only). 4/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 7 The timing diagram for the signals is illustrated in the chart functioning of the device. "External Calibration" on pages 10 or 11. KLASCHKA GB 5.17 5/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 8 Profibus connection at BDK/FP 6/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 9 Series Universal Double Sheet Metal Monitor Ref. no. 20.05-80, ...-81, ...-82, ...-93, 20.21-01 5.6. Main Menu KLASCHKA GB 5.17 7/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 10: Interfaces

    "External Calibration”), pages 9 + 10. has been measured (0 sheet or too thin). 8/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 11 Timing Diagram: Acknowledge Error Messages Timing Diagram: External Calibration DSP, BDWF, Externally BDWD, DSD, DSPW/FE KLASCHKA GB 5.17 9/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 12 Bit 6 Sensor fault. Bit 7 Selected sensor not calibrated or not valid. 10/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 13: Pulse Diagram For Interrogation Of Measured Value

    BDK with PLC-Interface 7.1.1. Internal Start of Measurement Timing Diagram of Measurement KLASCHKA GB 5.17 11/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 14 1 s a break of min. 1 s has to take place at the smallest possible repetition time. 12/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 15: Interconnection With Press Controller

    4. Interrogation 2, if K1 is pulled in or K0 and K2 have dropped out. KLASCHKA GB 5.17 13/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 16: Wiring

    RBST Housing Shielding Shield braid 14/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 17: Wiring Diagrams

    1 mA of the initiator is smaller than 1 mA. KLASCHKA GB 5.17 15/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 18: Housing Dimensions

    16/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 19 12.1.4. Air Gap Sensitivity with DSPW-54sg-1s (Fe sheets) 12.1.5. Air Gap Sensitivity with DSPW-54sg-1s (NE sheets) KLASCHKA GB 5.17 17/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 20 13.05-90 0.2 . . . 6.0 < 110 M75 x 1.5 3010 18/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 21 **) For using the DSPW-42sg-1s sensor, the evaluation device has to be equipped with software version E118 or higher. KLASCHKA GB 5.17 19/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 22 Sheet Metal Workpiece 20/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 23 Receiver BDWD/E-60aq30-1Y1 13.05-77 0.2 … 3.5 0.2 … 20 25 … 200 KLASCHKA GB 5.17 21/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 24 *) Measurement range and sheet thickness monitoring with software version E119 or higher (from July 2014). 22/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 25: Vlg Connecting Leads

    13.1. Configuration Example for Sheet Metal Thick- ness Sensors for Single Surface Monitoring KLASCHKA GB 5.17 23/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 26: Add1/2-1.3 T-Coupler

    (XS1 or XS2) sensor connection. 24/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 27: Bdiw Sensor Switch

    BDK-1.3 monitoring device. Please find more details in description KB 20.05-77. KLASCHKA GB 5.17 25/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 28: Bracket With Suction Cup For Mounting Sheet Thickness Sensor

    Suction cup for sensor Bellows for sensor ZBF/FB54-2 13.99-88 ZBF/FB54-1 13.99-68 bracket M54 bracket M54 26/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 29: Technical Data

    EMC emission EN 61000-6-4 EMC immunity EN 61000-6-2 KLASCHKA GB 5.17 27/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 30: Order Data (Designation / Ref. No.)

    Lead socket for connection of power supply leads for InterBus, PROFIBUS and Profinet devices. 28/29 GB 5.17 KLASCHKA © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...
  • Page 31: Data Backup

    Sensor bracket M54 x 0.75, spring-mounted, with suction ring, flexible shperical bearing ZBF/FBF54-2 13.99-87 KLASCHKA GB 5.17 29/29 © Klaschka Industrieelektronik GmbH • 75242 Neuhausen / Germany • Fon +49 7234 79-0 • Fax +49 7234 79-112 • e-mail: sales@klaschka.de • www.klaschka.de...

Table of Contents