"C" Programming Guide For Optimus S/R
6
7
7
7
7
8
9
9
9
9
9
1 - 0
Select Industrial 25 Start/Stop Pattern
00: Use Industrial 25 Start/Stop Pattern
01: Use Interleave 25 Start/Stop Pattern
10: Use Matrix 25 Start/Stop Pattern
11: Undefined
7 - 6
Select Matrix 25 Start/Stop Pattern
00: Use Industrial 25 Start/Stop Pattern
01: Use Interleave 25 Start/Stop Pattern
10: Use Matrix 25 Start/Stop Pattern
11: Undefined
5 - 4
Codabar Start/Stop Character
00: abcd/abcd
01: abcd/tn*e
10: ABCD/ABCD
11: ABCD/TN*E
3
1: Transmit Codabar Start/Stop Character
0: DO NOT transmit Codabar Start/Stop Character
2 - 0
Reserved
7 - 0
Reserved
7 - 6
MSI Check Digit Verification
00: Single Modulo 10
01: Double Modulo 10
10: Modulo 11 and Modulo 10
11: Undefined
5 - 4
MSI Check Digit Transmission
00: the last Check Digit is not transmitted
01: both Check Digits are transmitted
10: both Check Digits are NOT transmitted
3
1: Transmit Plessey Check Characters
0: DO NOT transmit Plessey Check Characters
2
1: Convert Standard Plessey to UK Plessey
0: No conversion
1
1: Convert UPCE to UPCA
0: No conversion