CIRCUIT DESCRIPTION

GENERAL DETAILS
• The low voltage transformer supplies the necessary
voltage to the micom controller when power cord is
plugged in.
• When the door is closed, the primary switch is ON, the
secondary switch is ON, and the monitor switch opens
(contact COM and NO).
WHEN SELECTING COOKING POWER
LEVEL AND TIME
• The micom controller memorizes the function you set.
• The time you set appears in the display window.
• Each indicator light turns on to indicate that the stage
has been set.
WHEN TOUCHING THE START PAD
• The coil of the relay is energized by the micom
controller.
• Power input is supplied to the high voltage transformer
through the fuse to top primary switch and relay 3
(208V : relay 4) and the btm primary switch and realy 5
(208V : relay 6).
• Stirrer fan rotates.
• The fan motor rotates and cools the magnetron by
blowing the air (coming from the intake on the base-
plate).
• The air is also directed into the oven to exhaust the
vapor in the oven through the upper plate.
• Cooking time starts counting down.
• 3.3 volts AC is generated from the filament winding of
the high voltage transformer. This 3.3 volts is applied to
the magnetron to heat the magnetron filament through
two noise-preventing choke coils.
• A high voltage of approximately 2100 volts AC is
generated in the secondary of the high voltage
transformer which is increased by the action of the high
voltage diode and charging of the high voltage
capacitor.
• The negative 4,000 Volts DC is applied to the filament
of the magnetron.
WHEN THE OVEN IS SET AT ANY LEVEL
EXCEPT MAXIMUM.
• The micom controller controls the ON-OFF time of relay
3 and relay 5 (208V : relay 4 & relay 6) by the applied
signal to vary the average output power of microwave
oven as POWER LEVEL. (refer to page 1-1)
• One complete cycle of relay 3 is 12.
WHEN THE DOOR IS OPENED DURING
COOKING
• Between the btm primary switch and relay 5
(208V : relay 6) and top primary switch and relay 3
(208V : relay 4) cut off the primary winding
voltage of the high voltage transformer.
• ON-OFF of relay 3 relay 5 (208V : relay 4 and relay 5)
is coupled electrically with opening and closing of the
secondary switch.
• When the door is opened, the secondary switch is
opened and when the door is closed, the secondary
switch is closed.
• The cooking time stops counting down.
• Relay stops functioning.
• As the door is opened, if the contact of top primary
switch and relay 3 (208V : relay 4) and the btm primary
switch and relay 5 (208V : relay 6) and/or secondary
switch fail to open, the fuse opens due to the large
current surge caused by the monitor switch activation,
which in turn stops magnetron oscillation.