Operating Instruction
Compact ejector SMPi 20 and 25
30.30.01.00491/03 | 05.2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMPi 20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Schmalz SMPi 20

  • Page 1 / SMP CH MAL Z Innovative Vacuum for Automation Operating Instruction Compact ejector SMPi 20 and 25 30.30.01.00491/03 | 05.2017...
  • Page 2: Table Of Contents

    / SMP CH MALZ ONTENTS Safety instructions ..................... 1-4 Important symbols ........................1-4 General safety information ......................1-4 Intended use ..........................1-5 Start-up ........................ 2-6 Installation and operation ......................2-6 Electrical connection ........................2-7 Pneumatic connection ......................... 2-7 Setting the blow-off volume flow ....................2-8 Description ......................
  • Page 3 / SMP CH MALZ Errors........................6-37 Troubleshooting ........................... 6-37 Error codes ..........................6-37 Technical data ....................7-38 Electrical data ..........................7-38 Electrical connection ........................7-40 Electric Connection ........................7-41 Internal wiring of electrical isolation .................... 7-41 Mechanical data ..........................7-42 Dimensions ..........................
  • Page 4: Safety Instructions

    / SMP CH MALZ AFETY INSTRUCTIONS Important symbols  This symbol identifies important information and instructions. Caution! This symbol identifies a potentially dangerous situation. If it is not avoided, slight or minor injuries may result. Danger! This symbol identifies an immediate hazard. If it is not avoided, death or serious injuries may result.
  • Page 5: Intended Use

    / SMP CH MALZ  Use only the connections, attachment holes and attachment materials that have been provided.  Carry out mounting and removal only when the device is in a disconnected, depressur- ised state.  Do not sit or stand in the area in which the picked-up payload is transported. ...
  • Page 6: Start-Up

    / SMP CH MALZ TART Installation and operation For safe installation and smooth operation, please observe and maintain the following points: The ejector may only be operated via power supply units with protected extra-low voltage (PELV). The system must incorporate safe electrical cut- off of the power supply in compliance with EN60204.
  • Page 7: Electrical Connection

    / SMP CH MALZ Electrical connection  The electrical connection of the ejector is made using 8-pin M12 male connector. The pin assignment is described in the “Technical data” chapter.  The plug connectors may not be connected or disconnected when the system is live. ...
  • Page 8: Setting The Blow-Off Volume Flow

    The blow-off volume flow can be set between 20% and 100%. ESCRIPTION Version overview Product name Art.-Nr. SMPi 20 IMP RD M12-8-PT SO (cpl. with connection distributor) 10.02.02.04441 SMPi 20 IMP RD M12-8-PT SO (without connection distributor) 10.02.02.04442 SMPi 25 IMP RD M12-8-PT SO (cpl. with connection distributor) 10.02.02.03480...
  • Page 9: Ejector Design

    / SMP CH MALZ Ejector design Item: Description Max. torque SMPi SMPi ISO-01 SMPi ISO-02 Operating and display elements G3/8“ 0,75 Nm G1/4“ 0,75 Nm "Blow-off" valve (NC valve) 0,75 Nm Button for operating the "blow-off" valve manually Vacuum connection with 3/8" thread 10 Nm 10 Nm 10 Nm...
  • Page 10: Operating And Display Elements

    / SMP CH MALZ Operating and display elements The ejector can be set and operated easily using the membrane keypad. The current vacuum and setting values are shown on the three-digit display. Item Description LED for blow-off valve Status display for system vacuum H1 LED (air-saving function) and H2 LED (parts control signal output) Display (3-digit/7-segment) DOWN button...
  • Page 11: General Function Description

    / SMP CH MALZ General function description ACUUM GENERATION WORKPIECE PICK The ejector is designed for handling parts using a vacuum together with suction systems. The Venturi nozzle is activated by the "suction" signal input. On IMP versions, the "suction" signal input is evaluated for its pulse.
  • Page 12 / SMP CH MALZ DEPOSITING THE WORKPIECE In "blow-off" mode, the vacuum circuit of the ejector is supplied with compressed air. This ensures that the vacuum drops quickly, depositing the workpiece quickly as well. "Blow-off" mode is activated by the "blow-off" signal input. "Suction"...
  • Page 13: Operating Modes

    / SMP CH MALZ Operating modes 3-13...
  • Page 14: Control Concept For Imp Ejectors

    / SMP CH MALZ Control concept for IMP ejectors Suction signal input Blow-off signal input Suction mode Blow-off mode  IMP ejectors are set to “Pneumatically OFF” on delivery. The ejector only starts the suction procedure after a valid pulse is sent through the suction signal input. 3-14...
  • Page 15: Status Display For System Vacuum

    / SMP CH MALZ Status display for system vacuum The ejector is equipped with a status display for the system vacuum and monitoring func- GREEN tions. System states are indicated in . The status display is updated after every suction cycle that is activated over the suction signal input. During conventional suction cycles, the status display is used to display the system vacuum level based on the H1 switching point.
  • Page 16 / SMP CH MALZ TATUS DISPLAY OVERVIEW Suction cycle with H1 reached VD ejectors RD ejectors: [ctr=on] and no leakage or [ctr=oFF] Suction cycle with vacuum- regulation (air-saving function) [ctr=on] RD ejectors: Suction cycle with vacuum- regulation (air-saving func- tion) where the valve protec- tion function was activated [ctr=on] RD ejectors:...
  • Page 17: Valve Leds

    / SMP CH MALZ Valve LEDs The suction and blow-off valves are each assigned an LED. LED state Ejector state No suction on ejector Suction on ejector is continuously lit IMP: Suction on ejector Suction valve Ejector blows off is continuously lit Blow-off valve Monitoring of the valve switching frequency (valve protection function) If the suction valve is triggered more than six times within three seconds by the air-saving...
  • Page 18: Operating And Menu Concepts

    / SMP CH MALZ PERATING AND MENU CONCEPTS The unit is operated via four buttons on the membrane keypad. Settings are made using software menus. The operating structure is divided into settings in the basic menu and con- figuration menu. Setting of the ejector in the basic menu is sufficient for standard applica- tions.
  • Page 19: Manual Mode

    / SMP CH MALZ Manual mode The output signals may change during set-up in manual mode. Ensure that the machine or system does not start moving as a result. Personal injury or damage to the ejector could occur as a result. Manual mode is used for locating and eliminating leaks in the vacuum circuit.
  • Page 20: Basic Menu

    / SMP CH MALZ ASIC MENU All settings for standard ejector applications can be made and observed using the basic menu.  4-22 Setting of switching points for the air-saving function  4-23 Setting of switching points for the signal output ...
  • Page 21 / SMP CH MALZ VERVIEW OF SWITCHING POINTS The ejector version with air-saving function is shown here (RD). Value Description Deactivation value for air-saving function Hysteresis of air-saving function H1-h1 Activation value for air-saving function Activation value for parts control signal output Hysteresis of parts control signal output H2-h2 Deactivation value for parts control signal output...
  • Page 22: Setting Of Switching Points For The Air-Saving Function With [H-1] And [H-1]

    / SMP CH MALZ Setting of switching points for the air-saving function with [H-1] and [h-1] [H-1] [h-1] The deactivation value and hysteresis of the air-saving function are set using this function. [H-1] When the deactivation value is reached or exceeded, then the H1 LED is also switched on.
  • Page 23: Setting Of Switching Points For The Signal Output With [H-2] And [H-2]

    / SMP CH MALZ Setting of switching points for the signal output with [H-2] and [h-2] [H-2] [no] [h-2] The activation value (when configuring the output) and hysteresis of the parts control signal output are set using this function. [H-2] When the value is reached or exceeded, then the H2 LED is also switched on.
  • Page 24: Zero-Point Adjustment (Calibration) [Cal]

    / SMP CH MALZ Zero-point adjustment (calibration) [CAL]  The vacuum circuit of the system must be ventilated to the outer atmosphere before zero-point adjustment is made. A zero-point adjustment is made as follows:  Press the button.  Enter a valid PIN if the menu is locked. [CAL] ...
  • Page 25: Counters, Software Versions And Serial Numbers

    / SMP CH MALZ OUNTERS SOFTWARE VERSIONS AND SERIAL NUMBERS  4-26 Cycle counters 1  4-26 Cycle counters 2  4-27 Software version  4-27 Serial number 4-25...
  • Page 26: Cycle Counters [Ct1] And [Ct2]

    / SMP CH MALZ Cycle counters [ct1] and [ct2] The ejector is equipped with two counters. Counter 1 is increased with each valid pulse on the suction signal input, and therefore counts the number of suction cycles in automatic mode. Counter 2 is increased with each switch of the suction valve. The switching frequen- cy of the air-saving function can then be determined from the difference between counters 1 and 2.
  • Page 27: Software Version [Soc]

    / SMP CH MALZ Software version [SoC] The software version indicates the software currently running on the internal controller. The software version is displayed as follows:  Press and hold the buttons together for more than 3 seconds.  Enter a valid PIN if the menu is locked. [SoC] ...
  • Page 28: Configuration Menu

    / SMP CH MALZ ONFIGURATION MENU An extended configuration menu is available for applications with special requirements. The operating structure is as follows:  4-30 Configuration of the vac- uum unit  4-30 Configuration of the sig- nal type  4-31 Configuration of the sig- nal output 4-28...
  • Page 29 / SMP CH MALZ  4-31 Configuration of the blow-off func- tion  4-32 Configuration of the signal type  4-33 Locking the menus using a PIN code  4-34 Resetting to the factory settings (Clear All) 4-29...
  • Page 30: Configuration Of The Vacuum Unit [Uni]

    / SMP CH MALZ Configuration of the vacuum unit [uni] The unit of the displayed vacuum can be set using this function. The vacuum unit is set as follows:  Press the button for more than 3 seconds.  Enter a valid PIN if the menu is locked. [uni] ...
  • Page 31: Configuration Of The Air-Saving Function [Ctr]

    / SMP CH MALZ Configuration of the air-saving function [ctr] This function is used to activate and deactivate the air-saving function. The air-saving function is configured as follows:  Press the button for more than 3 seconds.  Enter a valid PIN if the menu is locked. [ctr] ...
  • Page 32: Rotating The Display Screen [Dpy]

    / SMP CH MALZ Rotating the display screen [dPy] The display screen can be rotated by 180°. Rotate the display screen as follows:  Press the button for more than 3 seconds.  Enter a valid PIN if the menu is locked. [dPy] ...
  • Page 33: Locking The Menus Using A Pin Code [Pin]

    / SMP CH MALZ Locking the menus using a PIN code [Pin] Menus can be protected against unauthorised access by defining a PIN code [Pin]. The PIN code is set to “000” on delivery, meaning the menus are not locked. A ...
  • Page 34: Resetting To The Factory Settings (Clear All) [Res]

    / SMP CH MALZ Resetting to the factory settings (Clear All) [rES] This function is used to reset the ejector to its factory settings. All switching points and configurations are reset to the factory settings. The counters are not affected by this function. ...
  • Page 35: Maintenance

    / SMP CH MALZ AINTENANCE ENERAL MAINTENANCE Remove dirt from the outside of the ejector by cleaning with a soft cloth and soap suds (max. 60 °C). Ensure that the silencer and the controller are not soaked with soap suds. ILENCER MAINTENANCE The silencer can become very dirty from the increased effects of dust, oil or chips.
  • Page 36: Spare And Wearing Parts

    / SMP CH MALZ ARRANTY SPARE AND WEARING PARTS This ejector is guaranteed in accordance with our general terms of sale and delivery. The same applies for spare parts, provided that these are original parts supplied by us. We fully exclude liability for any damages arising from use of spare parts or accessories that are not original parts or accessories.
  • Page 37: Errors

    / SMP CH MALZ RRORS Troubleshooting Fault Possible cause Solution Silencer is soiled Replace silencer Leakage in hose line Check hose connections Vacuum level is not Leakage on suction pad Check suction pad reached or vacuum is Increase operating pressure created too slowly Operating pressure too low (observe max.
  • Page 38: Technical Data

    / SMP CH MALZ ECHNICAL DATA LECTRICAL DATA Operating the ejector system outside of the specified values can result in damage to the system and attached components. LECTRICAL PARAMETERS Limit values Parameter Unit Comment min. typ. max. Power supply for sensor 20,9 26,4 V DC PELV ...
  • Page 39 / SMP CH MALZ ISPLAY PARAMETERS Parameter Value Unit Comment Display Digit Red 7-segment LED display  Resolution Digit Unit = mbar = 25 °C, based on  Accuracy % FS FS final value (full-scale)  Linearity error  Offset error Digit Entered value after zero-point adjustment ...
  • Page 40: Electrical Connection

    / SMP CH MALZ Electrical connection The electrical connection of the ejector is made using an 8-pin M12 male connector. The pin assignment of the connector is as follows: – M12 8- (PT) PIN MALE CONNECTOR VERSION WITH POTENTIAL ISOLATION Connector Core color Symbol Function...
  • Page 41: Electric Connection

    / SMP CH MALZ Electric Connection Internal wiring of electrical isolation 7-41...
  • Page 42: Mechanical Data

    ECHANICAL PERFORMANCE DATA Air con- Air - Nozzle - Evacuation Suction - Noise - sumption consumption Weight 1+2) size level capacity level Type (suction) (blow-off) l/min l/min l/min SMPi 20 0,56 SMPi 25 0.56 At 4.5 bar with vacuum applied 7-42...
  • Page 43: Dimensions

    / SMP CH MALZ Dimensions SCPi / SMPi Type SCPi / SMPi 22,0 G1/4" G3/8" M12x1 181.5 131.5 71.5 internal internal external internal thread thread thread thread Type SCPi / SMPi 87.5 76.0 118.5 129.7 112.5 67.5 27.5 14.0 30.0 All dimensions are in mm.
  • Page 44 / SMP CH MALZ SMPi-ISO01 / ISO02 G1/4“-IG SMPi ISO02 M12x1- 115,5 71,5 118,5 G3/8“-IG SMPi ISO01 M12x1- 115,5 71,5 118,5 SMPi ISO02 112,5 74,5 31,25 SMPi ISO01 112,5 77,5 Maximum torque Connection Max. torque SMPi SMPi ISO-01 SMPi ISO-02 Torque of G1 thread 10 Nm 10 Nm...
  • Page 45: Pneumatic Circuit Plans

    / SMP CH MALZ Pneumatic circuit plans SMPi … IMP … SMPi … IMP … 7-45...
  • Page 46: Overview Of Display Symbols

    / SMP CH MALZ VERVIEW OF DISPLAY SYMBOLS Symbol Function Comment H1 switching point Deactivation value of the air-saving function h1 hysteresis Hysteresis of the air-saving function Activation value for the parts control signal output H2 switching point (when NO output is configured) h2 hysteresis Hysteresis of parts control signal output Zero-point adjustment...
  • Page 47: Factory Settings

    Air-saving function Ejector with air-saving function: Blow-off function Externally controlled blow-off Display Display screen not rotated PIN code The hysteresis 100mbar applies to the ejectors 10.02.02.04441and 10.02.02.04442, SMPi 20 IMP RD M12-8-PT SO (with and without connection distributor) 7-47...
  • Page 48: Declaration Of Conformity

    / SMP CH MALZ ECLARATION OF CONFORMITY 8-48...
  • Page 49 English. The right to make technical changes is reserved. No responsibility is taken for printing errors or other types of errors. All information and specifications may be changed without advanced notice. © J. Schmalz GmbH. All rights reserved. 8-49...
  • Page 50 Fax+91 (0) 20 4072 5588 Fax +34 94 4807264 schmalz@schmalz.co.in schmalz@schmalz.es Italy Tel. +39 0321 621510 Fax +39 0321 621714 schmalz@schmalz.it J. Schmalz GmbH Johannes-Schmalz-Str. 1 D-72293 Glatten Tel. +49 (0)7443 2403-0 Fax +49 (0)7443 2403-259 schmalz@schmalz.de 30.30.01.00491/03 | 05.2017 www.schmalz.com...