/ SMP CH MALZ AFETY INSTRUCTIONS Important symbols This symbol identifies important information and instructions. Caution! This symbol identifies a potentially dangerous situation. If it is not avoided, slight or minor injuries may result. Danger! This symbol identifies an immediate hazard. If it is not avoided, death or serious injuries may result.
/ SMP CH MALZ Use only the connections, attachment holes and attachment materials that have been provided. Carry out mounting and removal only when the device is in a disconnected, depressur- ised state. Do not sit or stand in the area in which the picked-up payload is transported. ...
/ SMP CH MALZ TART Installation and operation For safe installation and smooth operation, please observe and maintain the following points: The ejector may only be operated via power supply units with protected extra-low voltage (PELV). The system must incorporate safe electrical cut- off of the power supply in compliance with EN60204.
/ SMP CH MALZ Electrical connection The electrical connection of the ejector is made using 8-pin M12 male connector. The pin assignment is described in the “Technical data” chapter. The plug connectors may not be connected or disconnected when the system is live. ...
The blow-off volume flow can be set between 20% and 100%. ESCRIPTION Version overview Product name Art.-Nr. SMPi 20 IMP RD M12-8-PT SO (cpl. with connection distributor) 10.02.02.04441 SMPi 20 IMP RD M12-8-PT SO (without connection distributor) 10.02.02.04442 SMPi 25 IMP RD M12-8-PT SO (cpl. with connection distributor) 10.02.02.03480...
/ SMP CH MALZ Operating and display elements The ejector can be set and operated easily using the membrane keypad. The current vacuum and setting values are shown on the three-digit display. Item Description LED for blow-off valve Status display for system vacuum H1 LED (air-saving function) and H2 LED (parts control signal output) Display (3-digit/7-segment) DOWN button...
/ SMP CH MALZ General function description ACUUM GENERATION WORKPIECE PICK The ejector is designed for handling parts using a vacuum together with suction systems. The Venturi nozzle is activated by the "suction" signal input. On IMP versions, the "suction" signal input is evaluated for its pulse.
Page 12
/ SMP CH MALZ DEPOSITING THE WORKPIECE In "blow-off" mode, the vacuum circuit of the ejector is supplied with compressed air. This ensures that the vacuum drops quickly, depositing the workpiece quickly as well. "Blow-off" mode is activated by the "blow-off" signal input. "Suction"...
/ SMP CH MALZ Control concept for IMP ejectors Suction signal input Blow-off signal input Suction mode Blow-off mode IMP ejectors are set to “Pneumatically OFF” on delivery. The ejector only starts the suction procedure after a valid pulse is sent through the suction signal input. 3-14...
/ SMP CH MALZ Status display for system vacuum The ejector is equipped with a status display for the system vacuum and monitoring func- GREEN tions. System states are indicated in . The status display is updated after every suction cycle that is activated over the suction signal input. During conventional suction cycles, the status display is used to display the system vacuum level based on the H1 switching point.
Page 16
/ SMP CH MALZ TATUS DISPLAY OVERVIEW Suction cycle with H1 reached VD ejectors RD ejectors: [ctr=on] and no leakage or [ctr=oFF] Suction cycle with vacuum- regulation (air-saving function) [ctr=on] RD ejectors: Suction cycle with vacuum- regulation (air-saving func- tion) where the valve protec- tion function was activated [ctr=on] RD ejectors:...
/ SMP CH MALZ Valve LEDs The suction and blow-off valves are each assigned an LED. LED state Ejector state No suction on ejector Suction on ejector is continuously lit IMP: Suction on ejector Suction valve Ejector blows off is continuously lit Blow-off valve Monitoring of the valve switching frequency (valve protection function) If the suction valve is triggered more than six times within three seconds by the air-saving...
/ SMP CH MALZ PERATING AND MENU CONCEPTS The unit is operated via four buttons on the membrane keypad. Settings are made using software menus. The operating structure is divided into settings in the basic menu and con- figuration menu. Setting of the ejector in the basic menu is sufficient for standard applica- tions.
/ SMP CH MALZ Manual mode The output signals may change during set-up in manual mode. Ensure that the machine or system does not start moving as a result. Personal injury or damage to the ejector could occur as a result. Manual mode is used for locating and eliminating leaks in the vacuum circuit.
/ SMP CH MALZ ASIC MENU All settings for standard ejector applications can be made and observed using the basic menu. 4-22 Setting of switching points for the air-saving function 4-23 Setting of switching points for the signal output ...
Page 21
/ SMP CH MALZ VERVIEW OF SWITCHING POINTS The ejector version with air-saving function is shown here (RD). Value Description Deactivation value for air-saving function Hysteresis of air-saving function H1-h1 Activation value for air-saving function Activation value for parts control signal output Hysteresis of parts control signal output H2-h2 Deactivation value for parts control signal output...
/ SMP CH MALZ Setting of switching points for the air-saving function with [H-1] and [h-1] [H-1] [h-1] The deactivation value and hysteresis of the air-saving function are set using this function. [H-1] When the deactivation value is reached or exceeded, then the H1 LED is also switched on.
/ SMP CH MALZ Setting of switching points for the signal output with [H-2] and [h-2] [H-2] [no] [h-2] The activation value (when configuring the output) and hysteresis of the parts control signal output are set using this function. [H-2] When the value is reached or exceeded, then the H2 LED is also switched on.
/ SMP CH MALZ Zero-point adjustment (calibration) [CAL] The vacuum circuit of the system must be ventilated to the outer atmosphere before zero-point adjustment is made. A zero-point adjustment is made as follows: Press the button. Enter a valid PIN if the menu is locked. [CAL] ...
/ SMP CH MALZ Cycle counters [ct1] and [ct2] The ejector is equipped with two counters. Counter 1 is increased with each valid pulse on the suction signal input, and therefore counts the number of suction cycles in automatic mode. Counter 2 is increased with each switch of the suction valve. The switching frequen- cy of the air-saving function can then be determined from the difference between counters 1 and 2.
/ SMP CH MALZ Software version [SoC] The software version indicates the software currently running on the internal controller. The software version is displayed as follows: Press and hold the buttons together for more than 3 seconds. Enter a valid PIN if the menu is locked. [SoC] ...
/ SMP CH MALZ ONFIGURATION MENU An extended configuration menu is available for applications with special requirements. The operating structure is as follows: 4-30 Configuration of the vac- uum unit 4-30 Configuration of the sig- nal type 4-31 Configuration of the sig- nal output 4-28...
Page 29
/ SMP CH MALZ 4-31 Configuration of the blow-off func- tion 4-32 Configuration of the signal type 4-33 Locking the menus using a PIN code 4-34 Resetting to the factory settings (Clear All) 4-29...
/ SMP CH MALZ Configuration of the vacuum unit [uni] The unit of the displayed vacuum can be set using this function. The vacuum unit is set as follows: Press the button for more than 3 seconds. Enter a valid PIN if the menu is locked. [uni] ...
/ SMP CH MALZ Configuration of the air-saving function [ctr] This function is used to activate and deactivate the air-saving function. The air-saving function is configured as follows: Press the button for more than 3 seconds. Enter a valid PIN if the menu is locked. [ctr] ...
/ SMP CH MALZ Rotating the display screen [dPy] The display screen can be rotated by 180°. Rotate the display screen as follows: Press the button for more than 3 seconds. Enter a valid PIN if the menu is locked. [dPy] ...
/ SMP CH MALZ Locking the menus using a PIN code [Pin] Menus can be protected against unauthorised access by defining a PIN code [Pin]. The PIN code is set to “000” on delivery, meaning the menus are not locked. A ...
/ SMP CH MALZ Resetting to the factory settings (Clear All) [rES] This function is used to reset the ejector to its factory settings. All switching points and configurations are reset to the factory settings. The counters are not affected by this function. ...
/ SMP CH MALZ AINTENANCE ENERAL MAINTENANCE Remove dirt from the outside of the ejector by cleaning with a soft cloth and soap suds (max. 60 °C). Ensure that the silencer and the controller are not soaked with soap suds. ILENCER MAINTENANCE The silencer can become very dirty from the increased effects of dust, oil or chips.
/ SMP CH MALZ ARRANTY SPARE AND WEARING PARTS This ejector is guaranteed in accordance with our general terms of sale and delivery. The same applies for spare parts, provided that these are original parts supplied by us. We fully exclude liability for any damages arising from use of spare parts or accessories that are not original parts or accessories.
/ SMP CH MALZ RRORS Troubleshooting Fault Possible cause Solution Silencer is soiled Replace silencer Leakage in hose line Check hose connections Vacuum level is not Leakage on suction pad Check suction pad reached or vacuum is Increase operating pressure created too slowly Operating pressure too low (observe max.
/ SMP CH MALZ ECHNICAL DATA LECTRICAL DATA Operating the ejector system outside of the specified values can result in damage to the system and attached components. LECTRICAL PARAMETERS Limit values Parameter Unit Comment min. typ. max. Power supply for sensor 20,9 26,4 V DC PELV ...
Page 39
/ SMP CH MALZ ISPLAY PARAMETERS Parameter Value Unit Comment Display Digit Red 7-segment LED display Resolution Digit Unit = mbar = 25 °C, based on Accuracy % FS FS final value (full-scale) Linearity error Offset error Digit Entered value after zero-point adjustment ...
/ SMP CH MALZ Electrical connection The electrical connection of the ejector is made using an 8-pin M12 male connector. The pin assignment of the connector is as follows: – M12 8- (PT) PIN MALE CONNECTOR VERSION WITH POTENTIAL ISOLATION Connector Core color Symbol Function...
/ SMP CH MALZ VERVIEW OF DISPLAY SYMBOLS Symbol Function Comment H1 switching point Deactivation value of the air-saving function h1 hysteresis Hysteresis of the air-saving function Activation value for the parts control signal output H2 switching point (when NO output is configured) h2 hysteresis Hysteresis of parts control signal output Zero-point adjustment...
Air-saving function Ejector with air-saving function: Blow-off function Externally controlled blow-off Display Display screen not rotated PIN code The hysteresis 100mbar applies to the ejectors 10.02.02.04441and 10.02.02.04442, SMPi 20 IMP RD M12-8-PT SO (with and without connection distributor) 7-47...