Download Print this page

Battery Installation; Troubleshooting; Warranty And Service - Innoquest SpotOn SC-4 Product Manual

Sprayer calibrator

Advertisement

Available languages

Available languages

4.4 Battery Installation

Fig. 4
Please use care to pull the cap off the meter so that the bottom of the
meter is pointing upward. This will keep the batteries from falling out
of the meter once the cap comes free and putting extra stress on the
battery holder wires.
The meter requires two (2) N size alkaline
batteries which are available at any drug store.
batteries in the battery holder following the polarity indication marked
on the holder (negative end towards the spring). Place the rubber
retaining ring around the batteries once they are in the holder as
shown in Fig. 4. Then place the battery holder back into the end of
the meter and replace the black cap and press it firmly back onto the
meter.
When the meter's batteries need replacing, the meter will show "Lo b"
on the LCD display after the meter is turned on. If this message is
displayed, the batteries should be replaced as described above.
5.0 Trouble Shooting
The Spray Calibrator measures the flow rate by measuring the time it
takes to fill the meter's tube. The rising water level is sensed by 3
electrodes in the meter. The meter will only function with fluids that
conduct electricity, such as water. In the case of distilled water, the
conductivity may be too low for proper meter operation. All tap water
will work very well with the meter. Any substance that coats or covers
the exposed metal on the electrodes will hinder their ability to sense
the water level. Care should be taken to rinse the meter inside and
out with clean tap water when measurements are complete. This will
keep any foreign material from building up on the electrodes.
Complete rinsing will also keep the diffuser pad from becoming
clogged and therefore hindering the flow of water into or out of the
meter during operation.
The
batteries
housed inside the base
of the meter. The black
cap on the bottom of the
meter can be removed
by pulling it straight off
the end of the meter.
The cap is just a press
fit
onto
the
meter.
Place both new
6
6.0 Warranty & Service
are
One Year Warranty
Innoquest, Inc. warrants this product to be free from defects in
materials and workmanship under normal use and service for a period
one (1) year from date of purchase. This warranty extends only to the
original purchaser and shall not apply to any product which, in
Innoquest's sole opinion, has been subject to misuse, alteration,
abuse, or abnormal conditions of operation or handling. Innoquest's
obligation under this warranty is limited to repair or replacement of the
product which is returned to Innoquest. Innoquest accepts no liability
for whatever damages may be caused by a malfunctioning product.
Repair & Service Policy
Product returned to Innoquest for repair or service must follow the
guidelines set forth as follows: Return of the product for warranty or
service repair will be the responsibility of the purchaser (Innoquest
does not pay inbound shipping charges). All returns must receive an
RMA number by calling Innoquest prior to return of the product. The
RMA number must be clearly marked on the outside of the shipping
carton. If the customer is returning product for non-warranty related
repair or service, a minimum charge will apply for accessing the
product's repair needs and further work will not be completed without
the customer's approval.
910 Hobe Road
Woodstock, IL 60098
Toll Free: 800-637-1623
Phone: 815-337-8555
Fax: 815-337-8556
service@innoquestinc.com
www.innoquestinc.com
7

Advertisement