Page 3
These operating instructions provide the necessary information for proper operation of all models of the TIR-1. There may be information provided in this manual that is not relevant for your system. General knowledge of pulse oximetry and an understanding of the features and functions of TIR-1 are prerequisites for its proper use.
Bluetooth Function ------------------------------------------------------------------------------------ 16 Chapter 3: Basic Setup and Use ------------------------------------------------------------------------- 17 Installing Batteries ------------------------------------------------------------------------------------ 17 Body Temperature Measurement -------------------------------------------------------------------- 18 Pairing TIR-1 to a Masimo Device ------------------------------------------------------------------- 18 Chapter 4: Operation -------------------------------------------------------------------------------------- 21 TIR-1 Stand-Alone ------------------------------------------------------------------------------------- 21 TIR-1 with Root ----------------------------------------------------------------------------------------- 23...
Page 6
Guidance and Manufacturer's Declaration-Electromagnetic Emissions ---------------------- 39 Guidance and Manufacturer's Declaration-Electromagnetic Immunity ---------------------- 40 Symbols-------------------------------------------------------------------------------------------------- 42 Chapter 8: Service and Maintenance ------------------------------------------------------------------ 45 Maintenance and Cleaning -------------------------------------------------------------------------- 45 Service and Return Procedure ----------------------------------------------------------------------- 45 Contacting Masimo ------------------------------------------------------------------------------------ 46 Index --------------------------------------------------------------------------------------------------------- 49 www.masimo.com Masimo...
About this Manual This manual explains how to set up and use TIR-1™ Thermometer. Important safety information relating to general use of TIR-1 appears in this manual. Read and follow any warnings, cautions, and notes presented throughout this manual. The following are explanations of warnings, cautions, and notes.
Product Description, Features and Intended Use Product Description The TIR-1™ Thermometer is a noninvasive, infrared, clinical thermometer that can be used as a standalone device or with Masimo devices. Features Features of TIR-1 include: • Fast measurement that meets ASTM and ISO standards.
WARNING: Do not use TIR-1 during magnetic resonance imaging (MRI) or in an MRI environment. WARNING: Do not place TIR-1 or accessories in any position that might cause it to fall on the patient. WARNING: Do not use TIR-1 during defibrillation.
8 to 10 feet range of each other; moving outside of this range may cause a loss in connection. CAUTION: When paired to a Masimo device, the time and date of the Masimo device is used as the time stamp.
Page 13
TIR-1 Thermometer Safety Information, Warnings and Cautions Note: When using The TIR-1 with a device with wireless features, consideration should be taken to local government frequency allocations and technical parameters to minimize the possibility of interference to/from other wireless devices.
3 months old, persons with compromised immune systems, persons taking antibiotics, steroids or antipyretics (aspirin, ibuprofen, acetaminophen), or persons with certain chronic illnesses. Please consult your physician when you feel ill even if you do not have fever. www.masimo.com Masimo...
Chapter 2: Description General System Description The TIR-1™ Thermometer includes: • The TIR-1 device • Two (2) AA alkaline batteries • Infrared sensor cover Features Display 1. Low battery indicator 7. Room Temperature Indicator 2. Date Indicator 8. Bluetooth indicator 3.
Temperature may be transmitted from TIR-1 to a Masimo device using a Bluetooth connection. Pairing must be completed before data will be received. To pair TIR-1 to a Masimo device, see Pairing TIR-1 to a Masimo Device on page 18.
Always follow the instructions and close the battery cover by SLIDING only. • Set Date and Time as described in Setting Date/Time on page 21. • TIR-1 defaults to °F temperature scale and BODY mode. Note: If TIR-1 will be stored for a long period, remove the batteries. www.masimo.com Masimo...
For additional information on TIR-1 operation such as changing temperature scale and modes, see Chapter 4: Operation on page 21. Note: If temperature is suspected to be incorrect or display reads LO or HI, see TIR-1 Messages on page 31.
Page 21
TIR-1 should appear under the Devices Found list on the Masimo device screen. Select the TIR-1 thermometer under the Devices Found list. Note: The MAC Address for TIR-1 may also be displayed next to the name to assist in identifying the correct thermometer to pair.
CAUTION: When TIR-1 is paired to a Masimo device, the time and date of the Masimo device is used as the time stamp. To synchronize the date/time of the TIR-1 to the Masimo device, adjust the date/time settings on the TIR-1 to match the Masimo device.
Page 24
Setting Mode of Operation TIR-1 remains in the set Mode with each press of the Power/Start Measurement button. If TIR-1 is allowed to power OFF (as opposed to pressing the Power/Start Measurement button and taking a new measurement), the Mode changes back to Body.
Chapter 4: Operation Temperature Recall Up to 30 temperature measurements are stored on TIR-1 memory and can be viewed at a later time. Once 30 are reached, the oldest is deleted with each new measurement thereafter. If only 10 temperature readings are stored, only 10 stored temperatures can be recalled and displayed.
Page 26
After successfully pairing TIR-1 with the Masimo device, the temperature and scale data is transmitted with each measurement taken. The reading is displayed in the Temperature window on the Main Screen of the Masimo device, and the TIR-1 name is displayed at the top of the window (Root shown in the example).
Page 27
* Applies to Root with noninvasive blood pressure and temperature only. Available Layouts When a Radical-7 or Radius-7 is docked to Root and/or multiple MOC-9 modules and TIR-1 are connected, the user will have the option to select from several pre-configured layouts. Image below shows layout options available with Radical-7 docked in Root with SedLine connected through MOC-9, and TIR-1 is connected through Bluetooth.
Page 28
Active Channels When attempting to pair TIR-1 to a Root with noninvasive blood pressure and temperature, the temperature channel must be disabled in order to use TIR-1 with Root (if not, Unable to handle Temperature channel on bluetooth message displays).
Page 29
2 min Duration period of time. * When TIR-1 in NOT actively measuring and sending data to the Masimo device, these items are Grayed out. Trends for Temperature From the Temperature screen, touch Trends, and then change any of the following options:...
Page 30
Masimo device. The Masimo device temperature scale settings cannot change the temperature scale settings on TIR-1. Device Settings The Device Settings menu allows the user to view and customize settings for the Masimo device. The Device Settings options are: Bluetooth See Bluetooth on page 28.
Page 31
Thermometer* Pairs the TIR-1 thermometer to Pair Root. * After paring, the TIR-1 MAC address is displayed. The Pair button is also replaced with the Info button to access the Info Screen. See the Accessing the Thermometer Info Screen on page 29.
Page 32
MAC address** Displays the TIR-1 Bluetooth MAC address. * These fields are read-only and cannot be configured by the user. ** The MAC address is displayed on the Bluetooth screen as well as on the TIR-1 label on the device.
Manual for Root with noninvasive blood pressure and temperature. Alarms When TIR-1 is paired to a Root with noninvasive blood pressure and temperature with the temperature channel enabled, Unable to handle Temperature: Bluetooth message displays and a High priority alarm sounds.
Root Messages Message Explanation Alarm Next Step Priority Unable to handle A TIR-1 is paired, with the High On Root with noninvasive blood temperature channel pressure and temperature, Temperature: enabled, to a Root with disable the temperature channel Bluetooth before pairing TIR-1.
Operator's Manual for Root with noninvasive blood pressure and temperature. Symptom Possible Cause Correction • • The batteries in Replace the batteries in TIR-1 does not take a TIR-1 may be TIR-1. measurement when the depleted. Power/Start Measurement • TIR-1 requires service. See button is pressed.
Chapter 7: Specifications The following specifications apply to TIR-1 unless otherwise noted. For Root, the following information is to be used with the content in the Operator's Manual, Root® or the Operator's Manual, Root® with noninvasive blood pressure and temperature.
TIR-1 Thermometer Chapter 7: Specifications Body Mode Clinical Accuracy Temperature All patient populations. N=295. TIR-1 measuring site is center of Bias= -0.03°F forehead. (-0.02°C) Reference Body Site Number of Clinical Limits of Clinical Subjects Bias (°C) Agreement (°C) Repeatability (°C) Oral (Adults>5 yrs)
TIR-1 Thermometer Chapter 7: Specifications Electrical Battery Power Two 1.5V "AA" Alkaline Batteries Battery Life > 10,000 Temperatures (Typical) Batteries 2XAA Environmental Environmental Conditions Operating Temperature 10˚C to 40˚C (50˚F to 104˚F) Storage Temperature -20˚C to +60˚C (-4˚F to 140˚F)
TIR-1 Thermometer Chapter 7: Specifications Safety Standards Compliance IEC 60601-1-6 ANSI/AAMI ES 60601-1 ISO 80601-2-56 IEC/EN 60601-1 CSA C22.2 No. 60601-1 ASTM E1965-98 Equipment Classification per IEC 60601-1 Degree of Protection of Electrical Shock This device has been tested and conforms to ASTM.
TIR-1 Thermometer Chapter 7: Specifications Radio Compliance Radio Modes Bluetooth LE TM79030A01 FCC Parts 15.207 and 17.247 Canada RSS-210 Europe EN 300 328 EN 301 489-17 Guidance and Manufacturer's Declaration-Electromagnetic Emissions Guidance and Manufacturer's Declarations - Electromagnetic Emissions The ME Equipment is intended for use in the electromagnetic environment specified below.
TIR-1 Thermometer Chapter 7: Specifications Guidance and Manufacturer's Declaration-Electromagnetic Immunity Guidance and Manufacturer's Declaration - Electromagnetic Immunity The ME Equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the ME Equipment should assure that it is used in such an environment.
Page 43
TIR-1 Thermometer Chapter 7: Specifications Guidance and Manufacturer's Declaration - Electromagnetic Immunity Power frequency (50 / 3 A/m 3 A/m Power frequency magnetic fields 60 Hz) magnetic should be at levels characteristic of field. typical location in a typical hospital IEC 61000-4-8 environment.
TIR-1 Thermometer Chapter 7: Specifications Guidance and Manufacturer's Declaration - Electromagnetic Immunity Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. (a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
Page 45
TIR-1 Thermometer Chapter 7: Specifications Symbol Description Symbol Description Storage temperature range Fragile, handle with care Date of manufacture Manufacturer YYYY-MM-DD Not made with natural rubber Product contains no PVC latex (polyvinyl chloride) material Instructions/Directions for Use/Manuals are available in electronic format @http://www.Masimo.com/TechDocs...
Wait 10 minutes prior to taking temperature. Service and Return Procedure Contact Masimo for product support. If needed, an RMA will be provided for repair or replacement. Masimo can be reached at 800-326-4890. For customers outside the United States, local contact information can be found at http://service.masimo.com.
Products or Software. In no event shall Masimo’s liability arising from any Product or Software (under contract, warranty, tort, strict liability, or otherwise) exceed the amount paid by purchaser for the Product or Software.
Page 49
End-User License Agreement This document is a legal agreement between you (“purchaser”) and Masimo Corporation (“Masimo”) for the purchase of this Product (“Product”) and a license in the included or embedded Software (“Software”) except as otherwise expressly agreed in a separate contract for the acquisition of this Product, the following terms are the entire agreement between the parties regarding your purchase of this Product.
Need help?
Do you have a question about the TIR-1 and is the answer not in the manual?
Questions and answers