‡ SIGNET 8450-3 Pressure Transmitter
3-8450.090-3
CAUTION!
Remove power to unit before wiring
input and output connections.
Follow instructions carefully to avoid
personal injury.
1. Installation
ProcessPro transmitters are available in two styles: panel mount and field mount. The panel mount is supplied with the necessary
hardware to install the transmitter. This manual includes complete panel mounting instructions.
Field mounting requires one of two separate mounting kits. The 3-8052 integral kit joins the sensor and instrument together into a
single package. The 3-8050 Universal kit enables the transmitter to be installed virtually anywhere.
Detailed instructions for integral mounting or other field installation options are included with the 3-8052 Integral kit or the 3-8050
Universal kit.
1.1 Panel Installation
1.
The panel mount transmitter is designed for installation using a 1/4 DIN Punch. For manual panel cutout, an adhesive
template is provided as an installation guide. Recommended clearance on all sides between instruments is 1 inch.
2.
Place gasket on instrument, and install in panel.
3.
Slide mounting bracket over back of instrument until quick-clips snap into latches on side of instrument.
4.
To remove, secure instrument temporarily with tape from front or grip from rear of instrument. DO NOT RELEASE.
Press quick-clips outward and remove.
96 mm
(3.8 in.)
96 mm
(3.8 in.)
FRONT VIEW
Field Mount &
Panel Mount

2. Specifications

General
Compatibility: +GF+ SIGNET 2450 Pressure sensors
System accuracy: ±1% of full scale with 2450 sensors
Enclosure:
Rating:
NEMA 4X/IP65 front
Case:
PBT
Panel case gasket:
Neoprene
Window:
Polyurethane-coated polycarbonate
Keypad:
Sealed 4-key silicone rubber
Weight:
Approx. 325g (12 oz.)
Display:
Alphanumeric 2 x 16 LCD
Display update rate: 1 second
Contrast: User selected, 5 levels
Electrical
Power: 12 to 24 VDC ±10% regulated, 60 mA max current
Current output:
4 to 20 mA, isolated, fully adjustable and reversible
Max loop impedance:
50Ω max. @ 12 V, 325Ω max. @ 18 V, 600Ω max. @ 24 V
Update rate: 100 ms
Output accuracy: ±0.03 mA
‡ SIGNET 8450-3 Pressure Transmitter
C-1/01 English
96 mm
(3.8 in.)
107 mm
(4.2 in.)
SIDE VIEW
Field Mount
Contents
1. Installation
2. Specifications
3. Electrical Connections
4. Menu Functions
Optional
92 mm
Rear
(3.6 in.)
Cover
56 mm
41 mm
(2.2 in.)
)
(1.6 in.
97 mm
(3.8 in.)
SIDE VIEW
Panel Mount
Open-collector outputs:
Programmable for High or Low operation
Optically isolated, 50 mA max. sink
30 VDC maximum pull-up voltage.
Hysteresis:
User adjustable
Environmental
Operating temperature: -10 to 70°C (14 to 158°F)
Storage temperature:
Relative humidity:
Maximum altitude:
Insulation category:
Pollution degree:
Standards and Approvals:
CSA, CE, UL listed
Immunity:
EN50082-2
Emissions:
EN55011
Safety:
EN61010
Manufactured under ISO 9001 and ISO 14001
ENGLISH
Pressure
Pres1: 4.5 psi
Pres2: 2.3 psi
panel
gasket
terminals
latch
Panel Mount
Installation Detail
quick-clips
-15 to 80°C (5 to 176°F)
0 to 95%, non-condensing
2000 m (6562 ft)
II
2
page 1 of 8
ENTER
mounting
bracket

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8450-3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GF Signet 8450-3

  • Page 1: Specifications

    ‡ SIGNET 8450-3 Pressure Transmitter ENGLISH C-1/01 English 3-8450.090-3 Pressure Contents CAUTION! Pres1: 4.5 psi 1. Installation Pres2: 2.3 psi • Remove power to unit before wiring 2. Specifications input and output connections. 3. Electrical Connections • Follow instructions carefully to avoid 4.
  • Page 2: Electrical Connections

    15Ω Isolation Terminals 7-10: Open-collector Outputs Two transistor outputs programmable as High or Low alarm with adjustable hysteresis Outputs can be Disabled (Off) if not used ‡ SIGNET 8450-3 Pressure Transmitter page 2 of 8...
  • Page 3 Silver (Snsr 1 Gnd) Red (Snsr 1 IN) A + B ≤ 400 ft. (122 m) Black (Snsr 1 V+) +GF+ SIGNET 2450 Pressure Sensors Terminals Transmitter ≤ 400 ft. (122 m) ‡ SIGNET 8450-3 Pressure Transmitter page 3 of 8...
  • Page 4: View Menu

    10 minutes. Loop 2 Output: 7.65 mA Monitor date for scheduled maintenance or date of last calibration. This Last Cal 06-30-00 display will revert to the factory preset after 10 minutes. ‡ SIGNET 8450-3 Pressure Transmitter page 4 of 8...
  • Page 5 This will recall the last saved value of the item being edited and Output1 Setpnt: Saving return you to Step 3. Output1 Setpnt: 09.00 psi > ‡ SIGNET 8450-3 Pressure Transmitter page 5 of 8...
  • Page 6: Calibrate Menu

    High or Low selection). > Use this “note pad” to record important dates, such as annual recertification or Last Cal scheduled maintenance. 06-30-01 > Settings will repeat for Loop 2 and Output 2. ‡ SIGNET 8450-3 Pressure Transmitter page 6 of 8...
  • Page 7: Options Menu

    > Test Output 1 Press UP and DOWN keys to manually toggle the Open Collector output state. > Test Output 2 > Settings will repeat for Loop 2 and Output 2. ‡ SIGNET 8450-3 Pressure Transmitter page 7 of 8...
  • Page 8: Troubleshooting

    For Worldwide Sales and Service, visit our website: www.gfsignet.com • Or call (in the U.S.): (800) 854-4090 GEORGE FISCHER ‡ Piping Systems 3-8450.090-3/(C-1/01) English © Signet Scientific Company 2001 Printed in U.S.A. on recycled paper ‡ SIGNET 8450-3 Pressure Transmitter page 8 of 8...

Table of Contents