Do you have a question about the AMANDA Diva and is the answer not in the manual?
Questions and answers
Summary of Contents for Gekas Stoves AMANDA Diva
Page 1
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW AMANDA diva 16,1kW Carefully read all the instructions before the installation and use of the stove. This manual is an important part of the product. Address Gekas Metal Group - Gkekas Savvas & Yios OE Co...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW Dear customer, Thank you for placing your confidence in our company and congratulations for your choice! You are now the owner of a pellet boiler stove designed and manufactured by the Greek company Gekas Metal Group.
Page 3
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 5: Installing the stove ................................ 11 5.1: General information ............................11 5.2: Safety precautions ............................... 11 5.3: Connection to the chimney ..........................12 5.4: Connecting to a steel chimney ..........................12 5.5: Stove installation site ............................
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 1.4: MAIN REFERENCE STANDARDS 1: INTRODUCTION EN ISO 9001/2015: ‘’Certificate of quality • management system’’ 1.1: INTENDED USE EN ISO 14001/2015: ‘’Certificate of environmental • The product is a domestic heating stove, powered health and safety management system’’...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 1.7: IDENTIFICATION LABEL 1.9: TECHNICAL SPECIFICATIONS The serial number plate on the stove shows all the typical Model AMANDA Diva product data, including the manufacturer’s details, the serial number and CE markings.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW the stove is strictly prohibited due to the danger of 2: IMPORTANT INFORMATION explosion. 2.1: GENERAL INFORMATION • Use heat-resistant gloves to open the door of your Requesting information stove.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 2.3: FIRST HEATING The stove body, just as various steel parts, cast iron parts Please observe a minimum distance of 40 cm behind and and the flue pipes are painted with a heat resistant paint.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW For the selection of the connection and to ensure a proper 2.6: THE CORRECT CHIMNEY CONNECTION connection between the stove and chimney, please read There are several ways to connect your stove to the...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 3: BRIEF INFORMATION ON PELLETS Note Only burn pellets that have been inspected according to 3.1: WHAT ARE PELLETS? ENplus-A1. Using poor quality or prohibited pellet fuel will Wood pellets are a standardized fuel.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW eventually cause an explosion. In that case, the Emergency 4: TECHNOLOGY & SAFETY FUNCTIONS Pressure Relief Valve will engage releasing some of the The technological advances in your new stove are the pressure and smoke out of the stove and into the room result of years of testing and practical experience.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW • Clean using a vacuum cleaner 4.8: EASY CLEAN The stove features two Cleaning Levers for easy cleaning Make sure to screw and tighten the cap back in its place, of the stove.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW responsible for making sure the installation checks are • Avoid long flue pipes to the chimney. The horizontal completed. length of the flue pipe should not exceed 2 m.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW • It is also possible to suction in combustion air directly 5.5: STOVE INSTALLATION SITE from another sufficiently vented room (e.g. cellar). The paragraph 2.4: Safety distances shows the minimum •...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW The flue gas can be discharged through a traditional fire The system must be earthed and fitted with a residual place chimney as long as you make sure on the state of current circuit-breaker in accordance with legislation in maintenance of the chimney.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 5.11: POST-INSTALLATION WORK When the installation is finished, boiler ventilation should be performed. The automatic ventilator is on the right side of the appliance. Open the side cover and unscrew the valve on the top, until the trapped air in the boiler is fully removed.
Page 16
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 5.11.1: TYPICAL HYDRAULIC DIAGRAM: The hydraulic diagram is used as an example and not as installation plan. 1) Device 2) Circulator 3) Valve 4) Filter 5) Finishing valve...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 6: CONTROL PANEL 6.1: DESCRIPTION The control panel consists of: • A LED array on the top part of the controller with status LEDs and current menu indicators.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW On/Off Button Increase Water Temperature Increase Power Decrease Power Decrease Water Temperature The IR remote controller allows you to change certain basic functions without having to reach for the stove.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 6.4: CONTROL PANEL MENUS Icon Menu Submenu Description Values Power [1] Stove power Stove output setting. (Suggested Auto) 1 to 4 | Auto Up to 80°C Displays the room temperature reading Temperature [1] Water temperature and is used to set the desired temperature.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 7: PRELIMINARY CONTROL PANEL OPERATIONS 7.1: LOADING THE PELLETS The first operation to be performed before starting the appliance is to fill the hopper with fuel (pellets). The pellets are loaded into in the hopper using a scoop (not included).
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 8.3: SETTING THE BEEPER VOLUME a) Use the buttons to go to the Setup menu b) Use the buttons to scroll to and select submenu [4] and press...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 9: STOVE OPERATION 9.1: OPERATING PARAMETERS Stove operation is determined by the Power level, Fan and Temperature parameters set by the user. 9.1.1: SETTING THE POWER LEVEL The power level defines the amount of heat produced by the stove and consequently directly affects fuel consumption.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 9.3: MODIFYING THE PARAMETERS (SEE 8.4: IMPROVING THE COMBUSTION) The stove operating parameters can be modified as described. The values set will be retained until next modified, even when the stove is switched off or unplugged from the power supply.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 10: WEEKLY SCHEDULE 10.1: WEEKLY TIMER It’s possible to set, enable and assign, to each day of the week, customized programs to automatically switch the stove on and off.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW Example You can disable the Weekly Timer programs in the time of vacations. The following is an example of a set of 6 programs and their timeline: [P1]Program 1...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 12: ALARM MANAGEMENT If a malfunction occurs, you will hear an audible alarm, followed by one of the following system LEDs . If the problem concerns an error, the stove will switch off.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 13: CLEANING AND MAINTENANCE Only work on the unit when the main plug has been disconnected and the stove has cooled down completely. During assembly / dismantling do not allow objects (screws etc.) to fall into the pellet hopper – they can block the screw conveyor and damage the stove.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 14: PROBLEMS – POSSIBLE SOLUTIONS 14.1: PROBLEM 1 Fire burns with weak, orange flame. Pellets heap up in fire trough, window getting black. Cause(s) Insufficient combustion air •...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 15: WARRANTY Your new heater is accompanied by a two-year warranty, which is substantiated with the receipt or the invoice of payment, and it is valid for your heater if the following statements are true: •...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 16: INSTALLATION PROTOCOL Installation protocol filled and signed at the day of the installation of the stove Date: Installation address Dealer Name: Name: Street: Street: City: City: Telephone:...
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 17: DECOMMISSIONING AND DISPOSAL Decommissioning and disposal of the stove are exclusive responsibilities of the owner, who must act in accordance with the laws in force in the country where the stove is installed with regards to safety and environmental protection.
PRODUCT MANUAL Version 1.4 PELLET BOILER STOVE – AMANDA Diva 16,1 kW 18: PRODUCT FICHE Product fiche Unit Pellet Burning Stoves Model AMANDA diva AMANDA plus AMANDA standard Evita Energy efficiency class Α+ Α+ Α+ Α+ Direct heat output 12,8...
Need help?
Do you have a question about the AMANDA Diva and is the answer not in the manual?
Questions and answers