Advertisement

No. of Document: JPLM – 001/15
No. Of Revision: 04/ JPL-Medical
Date: 9. 9. 2015
Jett Plasma Lift Medical

User Manual

Before you start using Jet Plasma Lift, read this manual and make sure
you understand all instructions and warnings and follow them closely.
Made by Compex spol. s r.o. In Czech Republic
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Plasma Lift Medical and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JETT Plasma Lift Medical

  • Page 1: User Manual

    No. of Document: JPLM – 001/15 No. Of Revision: 04/ JPL-Medical Date: 9. 9. 2015 Jett Plasma Lift Medical User Manual Before you start using Jet Plasma Lift, read this manual and make sure you understand all instructions and warnings and follow them closely.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. Introduction – General Information ..................... 3 1.1. Package Contents ......................... 4 2. Intended use ............................5 3. Indications and contraindications ......................5 3.1. Indications ............................ 5 3.2 Contraidnications ........................... 6 4. Function Description ........................... 6 5. Description of Symbols ........................7 5.1 Symbols on the cover of the device, on the device and its equipement ........
  • Page 3: Introduction - General Information

    Plasma discharge can operate Jett Plasma Lift. Before using Jett Plasma Lift, it is necessary to read and understand all instructions and safety precautions in this Manual and you are obliged to follow them. During the treatment, make sure that you follow all safety instructions.
  • Page 4: Package Contents

    1.1. Package Contents Jett Plasma Lift Medical with applicator Foam electrodes 60 pcs of disposable sticking solid gel grounding CE electrodes 51×33 mm č.v.:300612979 Flat applicator Golden applicator with pointed tip Cone applicator Type: DA12-050EU-M Input: 100-240V/50-60Hz AC adapter Output: 5VDC, max 2.0A Power: max.
  • Page 5: Intended Use

    2. Intended use JETT PLASMA LIFT MEDICAL is a medical device that uses the physical principle of the succession of sparkle discharge generated by DC. It is used to treat skin, stop small bleeding, removal of small warts, hemangiomas mesenchyme tumors of veins and undesirable skin structures, venectasia, melisma, fibroma and keratosis.
  • Page 6: Contraidnications

    AC part due to an oscillation (instability) of spark discharge. As it has been already stated, Jett Plasma Lift Medical is a medical device that can be operated only by a provably trained doctors. The main reason for this is that the energy absorbed by body can be, in cases of some applications, used for targeted destruction of skin cells.
  • Page 7: Description Of Symbols

    Electrodessication is evaporation of cell liquids with a subsequent destruction of subcutaneous cells. Evaporation is caused by thermal energy generated by oscillating spark discharge. A relatively low electric power, at maximum 1.8 W is applied and as it affects only a small area, it is able to cause the evaporation of cell liquids.
  • Page 8: Symbols On The Cover Of The Device, On The Device And Its Equipement

    5.1 Symbols on the cover of the device, on the device and its equipment Graphic sign: Warning from a possible danger, follow instructions in the manual. Graphic sign: Manufacturer Graphic sign: Serial number Graphic sign: Applicator of the BF type: flat applicator and disposable electrodes Graphic sign: Electric waste, after the end of the lifespan of the device, it must not be disposed of in communal waste.
  • Page 9 Graphic sign: Range of temperatures for storage and transport. Graphic sign: Range of pressure min. 50 kPa max. 106 kPa Graphic sign: Humidity limitations, min. 30%, max..75%. Graphic sign: Protect from rain Labels at the rear side of the device: Flat applicator Applied part of the BF type...
  • Page 10: Symbols From The Manual

    5.2 Symbols from the Manual The text with the label “PRECAUTION” covers possible dangers =PRECAUTION! that could cause minor or medium injuries or a damage of the device. The text with the label “WARNING” covers possible dangers that =WARNING! could cause serious injuries or a destruction of the device. The text with the label “DANGER”...
  • Page 11 Training of the operators is provided either by the manufacturer or authorized distributor. The trained staff receives a certificate entitling is holder to work with Jett Plasma Lift Medical. The trained staff must make sure that in his workplace untrained people can´t work with the device.
  • Page 12 Changing of application tip – Danger: When the application tip is being used, Jett Plasma Lift Device MUST BE unplugged from the power source. The device has 3 applicators – a spike, a flat applicator and a tip with a slim spike.
  • Page 13: Operation Of The Device

     Danger of skin damage! Plasma Jett Lift Medical device set on the intensity of 6, 7 and 8 can irreparably damage skin cells (evaporation of warts). You should be constantly aware of the fact that the device can destroy skin cells at the intensity of 6, 7 and 8.
  • Page 14 Plug the adaptor the power source (230V, 50Hz) and plug the other side of the supply connector into the slot of Jett Plasma Lift Medical (10). The device switches on automatically and a message “TAPE” appears on the screen, telling you that the patient must be grounded.
  • Page 15 If you want to increase the intensity from the level 6 to the level 7, touch and hold the “+” button (12) for 2 second and then it is possible to increase the intensity by the held button. g) Types of applicators and their use 1) Flat and conic applicator Flat and conic applicators are used only for cosmetic treatments (intensities 1-5) of stretchmark, wrinkles and rejuvenation.
  • Page 16 Fig. 1: Registered design no. 27650 h) Caution As soon as the device is switched on, the spark discharge creating Plasma is ignited between the tip of the device and patient´s grounded skin and the device starts a continual control of the current running through patient.
  • Page 17: Definition Of Plasma

    Plasma is created in al discharges in all current electrocauters in fulguration mode. Jett Plasma Lift Medical uses this phenomenon by its ability to generate the flow of Plasma. This flow affects biological tissues and it triggers a specific reaction...
  • Page 18: The Nature Of Discharge Generating

    peeling, tissue recovery, its tightening, improvement of flexibility and it also stimulates immunity and resistance of tissues. 8.1 The nature of discharge generating The spark discharge itself is generated by a high voltage of 4 – 6 kV at a very low current < 1 mA.
  • Page 19: Use

    (depending on the used frequency and intensity). The depolarization does not occur because AC current is not able to pass through cell membranes. Jett Plasma Lift Medical was designed to for controlled destruction of skin cells and other cells at the higher intensities of adjustable spark discharge. This is achieved thanks to...
  • Page 20 After this sequence, the effect of the treatment lasts up to half a year. Then it is necessary to repeat the sequence based on the individual results. We recommend to repeat the treatment once a month for lasting effect. Results before and after the treatment with Jett Plasma Lift Medical:...
  • Page 21: Working Protocols For The Treatments

    12. Working protocols for the treatments 1. Skin must be properly cleaned. Deep and surface cleaning are necessary to prepare the skin for the absorption of plasma discharges. 2. Properly cleaned skin must be heated thoroughly, which causes dilatation of collagen tissues.
  • Page 22: Technical Information, Warranty, Service, Periodical Safety Technical Checks In The Given Period

    +5°C – 40°C and relative humidity of air up to 10- 100% without condensation. Range of atmospheric pressure: 50kPa to 106 kPa. Any kind of modification the medical device Jett Plasma Lift Medical is strictly forbidden!
  • Page 23: Warranty

    13.2 Warranty This product is covered by the warranty including the material imperfections and production faults for one year after the supply of the product. The manufacturer agrees to repair or change the product or its faulty parts in the time covered by the warranty, it these repairs are done by the manufacturer or its authorized agents.
  • Page 24 The waste consisting of electrical or electronic devices may contain substance that may be harmful for the environment or health. Jett Plasma Lift Medical is included in the electric waste and after the end of its lifespan, it must not be disposed of in communal waste.
  • Page 25: Service

    The manufacturer has a system of authorized service centers, For more information see www.jettcosmetics.cz 13.5 The Device Label Compex spol. s. r. o. Palackého třída 105, 612 00 Brno Czech Republic tel. : 00420 602 766 759 www.jettmedical.cz Jett Plasma Lift Medical 0001/15 1023...
  • Page 26: Manufacturing Labels

    13.6. Manufacturing labels Compex spol. s. r. o. Palackého třída 105, 612 00 Brno, Czech Republic tel. : 00420 602 766 759 www.jettmedical.cz Flat applicator A 0001/15 DATE OF MANUFACTURE: 15/2/2015 Compex spol. s. r. o. Palackého třída 105, 612 00 Brno Czech Republic tel.