Download Print this page

Specification - LG Multi V ARNU07GTJ 2 Series Svc Manual

Exploded view

Advertisement

1. Specification

Type
Model
Cooling Capacity
Heating Capacity
Casing
Body
Dimensions (WxDxH)
Front Panel
Rows x Columns x FPI
Coil
Face Area
Type
Motor Output x Number
Running Current
Fan
Air Flow Rate(H/M/L)
Drive
Motor type
Temperature Control
Sound Absorbing Thermal Insulation Material
Safety Device
Liquid Side
Pipe Connections Gas Side
Drain Pipe(Internal Dia.)
Net Weight
Body
Noise Level(Sound Press, 1.5m, H/M/L)
Power Supply
Refrigerant Control
Power cable
Transmission cable
Panel Color
Panel Name(Acc'y)
Notes:-
1. Capacities are based on the following conditions:
Cooling
• Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
Heating
• Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Unit
ARNU07GTJ*2
kW
2.2
1,900
kcal/h
Btu/h
7,500
kW
2.5
kcal/h
2,200
Btu/h
8,500
Galvanized Steel Plate
mm
860x410x138
inch
33.8x16.1x5.4
mm
1,070x480x20
inch
42.1x18.9x0.8
2x9x21
m
2
0.13
Cross Flow Fan
W
20.0
A
0.18
CMM
7.5/6.5/6
cfm
265/229/212
Direct
BLDC
Mi c roprocessor, Thermostat for cool i n g and heati n g Mi c roprocessor, Thermostat for cool i n g and heati n g Mi c roprocessor, Thermostat for cool i n g and heati n g
Foamed polystrene
Fuse
Ø6.35(1/4)
mm(inch)
mm(inch)
Ø12.7(1/2)
mm
25.0
11.5(25.4)
kg(lbs)
dB(A)
40/38/37
1, 220 ~ 240, 50
Ø, V, Hz
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog
- 2 -
* Model Name
1Way Ceiling Cassette
ARNU09GTJ*2
2.8
2,400
9,600
3.2
2,800
10,900
Galvanized Steel Plate
Galvanized Steel Plate
860x410x138
33.8x16.1x5.4
1,070x480x20
42.1x18.9x0.8
2x9x21
0.13
Cross Flow Fan
20.0
0.18
7.5/6.5/6
265/229/212
Direct
BLDC
Foamed polystrene
Fuse
Ø6.35(1/4)
Ø12.7(1/2)
25.0
11.5(25.4)
40/38/37
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog
PT-HJ *
LGE Internal Use Only
A:Basic, C:Plasma
ARNU12GTJ*2
3.6
3,100
12,300
4.0
3,400
13,600
860x410x138
33.8x16.1x5.4
1,070x480x20
42.1x18.9x0.8
2x9x21
0.13
Cross Flow Fan
20.0
0.18
8/7/6
283/247/212
Direct
BLDC
Foamed polystrene
Fuse
Ø6.35(1/4)
Ø12.7(1/2)
25.0
11.5(25.4)
41/39/37
1, 220 ~ 240, 50
1, 220, 60
EEV
CV1.5 x 3C
CVV-SB 1.25 x 2C
Morning fog
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60

Advertisement

loading

This manual is also suitable for:

Multi v arnu09gtj 2 seriesMulti v arnu12gtj 2 series