9.0 INSPECTION CHECKLIST

Monitor must be inspected for proper operation and function according to this checklist before each use. Before flowing water
check:
GENERAL
There is no obvious damage such as missing,
1
broken, or loose parts.
2
Hose(s) and nozzle are securely attached.
PORTABLE BASE
3
Legs are fully opened and locked in place.
4
All leg spikes are in contact with the ground.
5
Monitor is securely tied down with no slack
in anchor strap.
6
Safety valve operates freely.
WARNING
TASK FORCE TIPS, Inc.
MADE IN USA •www.tft.com
©Copyright Task Force Tips, Inc. 1999-2010
Any monitor failing any part of the inspection checklist is unsafe and must have the
problem corrected before use. Operating a monitor that fails any of the above
inspections is a misuse of this equipment.
MONITOR TOP
7
Monitor top is securely attached.
A
8
Nozzle elevation is above safety stop.
9
Elevation handwheel adjusts elevation freely.
10
Monitor top freely swivels on base when
unlocked.
11
Rotation lock lever securely locks rotation.
12
Monitor is pointed in a safe direction.
3701 Innovation Way, Valparaiso IN 46383-9327 USA
800-348-2686 • 219-462-6161 • Fax 219-464-7155
B
C
35°
LIX-030 June 21, 2010 Rev18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Crossfire with Safe-Tak 1250 Base and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents