Proximity keypad

Advertisement

FTK5 PROXIMITY KEYPAD
Before using the unit, please read the instructions and retain for future reference
Fortessa_FTK5_Instructions_Rev01
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTK5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for fortessa FTK5

  • Page 1 FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference Fortessa_FTK5_Instructions_Rev01...
  • Page 2 There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records will be required for future reference, please refer to last page of the instructions for an example sheet. Important Note: If a code is required then this has to be programmed with a fob or card To add fob or card From quiescent state: Constant Blue LED (default) 1 2 3 4...
  • Page 3 To Change the Lock Output Time (Default 5 Seconds) From quiescent state: Constant Blue LED (default) 1 2 3 4, 1 2 3 4 Enter programming code (default 1234): (unless changed) – Long beep, Yellow LED 8 2 0 T T # Enter: (T T equals time in seconds i.e.
  • Page 4 Keypad Lock Out – Incorrect Code Entry Option to lock the keypad for 30 seconds on 4 incorrect code entries only, when the keypad is in the lock mode the proximity sensor is also disabled From quiescent state: Constant Blue LED (default) 1 2 3 4, 1 2 3 4 Enter programming code (default 1234): (default unless changed)
  • Page 5 To Change Alarm Output Time (Default 030 Seconds) When the alarm output is activated the keypad tone will also sound, an active fob or code will be required to reset the keypad From quiescent state: Constant Blue LED (default) 1 2 3 4, 1 2 3 4 Enter programming code (default 1234): (unless changed) –...
  • Page 6 1 Gang Box Fortessa_FTK5_Instructions_Rev01...
  • Page 7 Wiring Diagram Magnetic Lock (Failsafe) Varistor Wiring Diagram DLU1 Lock (Failsecure) If door contact or reed switch is not used then ensure the Reed jumper is inserted 12/24v AC/DC O/P(-) Lock Output AUX Output REED P.B. 12V DC DLU1 Failsecure Lock 230V SUPPLY Fortessa_FTK5_Instructions_Rev01...
  • Page 8 Fob or Card ID Number Keypad User Number Named Holder Example: 0214561967 Mrs J Smith For Additional fobs please use blank sheet on following page Fortessa_FTK5_Instructions_Rev01...
  • Page 9 Fob or Card ID Number Keypad User Number Named Holder Fortessa_FTK5_Instructions_Rev01...
  • Page 10 Quick Reference Table Function Programming Code Factory Default Changed Notes Change Master 0 0 0 1 2 3 4 Password Setup User Password or 001 – 600 0 0 1 = 3 3 3 3 Access Mode 8 1 0 0 = Card or Code Lock Output time 8 2 0...