Altronic AGV5 Series Service Manual

Gas metering valve

Advertisement

Quick Links

ALTRONIC AGV5
GAS METERING VALVE
PROPER INSTALLATION, MAINTENANCE, REPAIR AND OPERATION OF
THIS EQUIPMENT IS ESSENTIAL.
CONTAINED HEREIN SHOULD BE FOLLOWED WITHOUT DEVIATION. AN
IMPROPERLY INSTALLED OR OPERATING VALVE SYSTEM COULD CAUSE
PERSONAL INJURY TO OPERATORS OR OTHER NEARBY PERSONNEL.
ALTRONIC ,INC.
712 TRUMBULL AVE.
GIRARD, OHIO 44420
GAS METERING VALVE
AGV5-1
AGV5-1A
AGV5-2
AGV5-2A
IMPORTANT SAFETY NOTICE
THE RECOMMENDED PRACTICES
SERVICE MANUAL
FORM AGV5 SM 11-03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGV5 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronic AGV5 Series

  • Page 1 ALTRONIC AGV5 SERVICE MANUAL GAS METERING VALVE FORM AGV5 SM 11-03 ALTRONIC ,INC. 712 TRUMBULL AVE. GIRARD, OHIO 44420 GAS METERING VALVE AGV5-1 AGV5-1A AGV5-2 AGV5-2A IMPORTANT SAFETY NOTICE PROPER INSTALLATION, MAINTENANCE, REPAIR AND OPERATION OF THIS EQUIPMENT IS ESSENTIAL.
  • Page 2 TABLE OF CONTENTS ALTRONIC AGV5 SERVICE MANUAL SECTION ITEM PAGE VALVE SERVICE AND REPAIR MANUAL OVERVIEW PARTS IDENTIFICATION REPLACEMENT OR UPDATE OF PCB ASSEMBLY REPLACEMENT OF THE PRESSURE TRANSDUCER PRESSURE TESTING OF AGV5 VALVE...
  • Page 3 Since calibration of the valve requires equipment not normally available in the field, it is recommended that the device be returned to the Altronic distributor serving your area. Throughout this service manual service parts will be identified by the item number assigned to them in the parts list.
  • Page 5: Parts Identification

    2.0 PARTS IDENTIFICATION 2.1 PARTS LIST - AGV5 Reference exploded view on 1A. ITEM NO. QUANTITY PART NO. DESCRIPTION 881002-KT PC B F ield Re trofit Kit 872005 PC B A ss em bly, Logic 810114 Bushing, Magnet 810112 Asse m bly, Mag net Holder 801008 W asher, Flat #4 801009...
  • Page 7 2.2 PARTS LIST - AGV5 Reference exploded view on 1B. ITEM NO. QUANTITY PART NO. DESCRIPTION 881002-KT PC B F ield Re trofit Kit 872005 PC B A ss em bly, Logic 810114 Bushing, Magnet 810112 Asse m bly, Mag net holder 801008 W asher, Flat #4 801009...
  • Page 9 2.3 PARTS LIST - AGV5 Reference exploded view on 1C. ITEM NO. QUANTITY PART NO. DESCRIPTION 881002-KT PC B F ield Re trofit Kit 872005 PC B A ss em bly, Logic 810114 Bushing, Magnet 810112 Asse m bly, Mag net Holder 801008 W asher, Flat #4 801009...
  • Page 11 2.4 PARTS LIST - AGV5 Reference exploded view on FIG. 1D. ITEM NO. QUANTITY PART NO. DESCRIPTION 881002-KT PC B F ield Re trofit Kit 872005 PC B A ss em bly, Logic 810114 Bushing, Magnet 810112 Asse m bly, Mag net Holder 801008 W asher, Flat #4 801009...
  • Page 13 820022. 3.2 Retain all removed parts in a small plastic bag. These parts should be returned to Altronic, Inc. for exchange credit. 3.3 The following tools are required for the removal and installation of PCB assembly (1a): a spanner or strap wrench, a small Phillips head screw driver, wire cutter/strippers and an Allen wrench set.
  • Page 14 Remove the LVDT core from the shaft attaching it to the poppet assembly by carefully unscrewing the core from the 4-40 threaded stud (Allen head set screw) which holds it. See FIG.1C. The new magnet holder assembly (1c) is installed by threading onto the 4-40 threaded stud.
  • Page 15: Pressure Control

    Power up the AGV5 and the Display Module will go to the HOME screen of the AGV5 program within 1 minute. The HOME screen is shown below. The first line of the display indicates the status of the valve; with the input control current set to 4 milliamperes or less, the valve is OFF or closed.
  • Page 16: Hardware Config

    Press the setup key until the display shown below appears. The sensor voltage value for the minimum open position can now be entered. Recall the value read and recorded in section 3.5, step B. This value plus 50 millivolts should be used for the MINPOS value.
  • Page 17 4.1 Replacement of pressure transducer (27a) can be performed in the field under the direction of the distributor or Altronic personnel. The transducer (27a) is supplied in a kit (27) which includes all of the necessary parts. NOTE: When repairing or updating existing AGV5 units with S/N 1400 or lower, the obsolete pressure transducer and transducer housing as well as the PCB assembly MUST be replaced.
  • Page 18 Disconnect the transducer (27a) from the electronics board (1a) and remove the board (1a) from the transducer housing assembly (19). Do not remove more wires than necessary. Using snap ring pliers, remove the snap ring (27b) holding the transducer (27a). With a small pry tool, remove the transducer (27a) from its housing.