KTC-2 (MS9)
Software-Update Version 1.0.10 manual
In order to keep your door systems updated, please proceed with the following
changes.
1.
Exchange CPU -Z1 (E60-0228-10) by the new one you already received.
Front view
Relay K3-K7
Terminal block –X101/-X100
Microcell Three control
unit
(N60-0685)
Module for locking device
(E60-0120)
Output module
(E60-0119)
Input module
(E60-0118)
CPU –Z1 (E60-0228-10)
Stand 08.02.2012
Technische Änderungen vorbehalten
Seite 1 von 14
DORMA KT-Systeme
Software-Update_Ver1010_GB.doc

Advertisement

loading
Need help?

Need help?

Do you have a question about the KTC-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dorma KTC-2

  • Page 1 KTC-2 (MS9) Software-Update Version 1.0.10 manual In order to keep your door systems updated, please proceed with the following changes. Exchange CPU -Z1 (E60-0228-10) by the new one you already received. Front view Relay K3-K7 Terminal block –X101/-X100 Microcell Three control...
  • Page 2 KTC-2 (MS9) Rear view Frequency converter (N60-0402) Mains filter (N60-0405) Mains connection 230 V AC –X103 24 V DC power supply unit (N60-0583) Relay K1 (N60-0560) Service power outlet max. 300 W (N60-0694) Collector (230VAC)-X105 Potentiometer for 24V DC adjustment Readout the parameter settings before exchanging, in order to transfer these to the new CPU.
  • Page 3 KTC-2 (MS9) The following chart shows the setting entries: values are shown here, they may however vary. standard Parameters Parameter Symbo Description Unit Range Original designation setting Current error Error list status Door diameter Door diameter 2000 .. 6500 (system...
  • Page 4 KTC-2 (MS9) 2. Reconnect at the locking module „IL1“. OUT4 OLD: Stand 08.02.2012 Technische Änderungen vorbehalten Seite 4 von 14 DORMA KT-Systeme Software-Update_Ver1010_GB.doc...
  • Page 5 KTC-2 (MS9) NEW: Stand 08.02.2012 Technische Änderungen vorbehalten Seite 5 von 14 DORMA KT-Systeme Software-Update_Ver1010_GB.doc...
  • Page 6 KTC-2 (MS9) 3. Please check if terminals X101:59 and 60 are connected to -IL1(see picture). For doors with integrated sliding doors bridge –X101:+ with 60, please! Stand 08.02.2012 Technische Änderungen vorbehalten Seite 6 von 14 DORMA KT-Systeme Software-Update_Ver1010_GB.doc...
  • Page 7 KTC-2 (MS9) 4. Change the following in the UPS monitoring circuit: New terminal strips –X105 Additional relay K7 (230VAC-version) Exchange the old terminal strip –X105 by the new one and install the additional relay K7. Wiring as follows: NEW “K7”...
  • Page 8 KTC-2 (MS9) Stand 08.02.2012 Technische Änderungen vorbehalten Seite 8 von 14 DORMA KT-Systeme Software-Update_Ver1010_GB.doc...
  • Page 9 KTC-2 (MS9) 5. Carry out the wiring as follows if the door system is furnished with UPS: If a UPS is joined up in circuit, put the inlet connector for non-heating apparatus from –X103 into the UPS and the other 230VAC adapter cable to be connected between UPS and control system at –X103.
  • Page 10 KTC-2 (MS9) 6. Is the door system without UPS, please proceed with the wiring as follows: Stand 08.02.2012 Technische Änderungen vorbehalten Seite 10 von 14 DORMA KT-Systeme Software-Update_Ver1010_GB.doc...
  • Page 11 KTC-2 (MS9) 7. Re-wire the inputs in the rotating part „I1“ here IN10+11 as follows: Stand 08.02.2012 Technische Änderungen vorbehalten Seite 11 von 14 DORMA KT-Systeme Software-Update_Ver1010_GB.doc...
  • Page 12 KTC-2 (MS9) 8. Adjust the crossover cable from the MS9 control system to ES200. Connect the delivered 2-wire cable with the terminals – „33.1 ES200-Not Halt“ X101:33/34 and ES200:32/33. Remove bridge (ES200: 32-33) at ES200 beforehand. New connection Terminal “47” is connected to +24VDC Stand 08.02.2012...
  • Page 13 KTC-2 (MS9) 9. Change of emergency-stop logic. The ES200 drive will be stopped by emergency-stop when activated. The auxiliary contactor must be put on „K1“ contactor. N60-0460 Normally open K1:53 and 54 to be connected to the terminals –X101:33 and 34 as...
  • Page 14 KTC-2 (MS9) If all changes are carried out, please put the door system back into operation as follows: 10. Initial operation of the door system  The emergency-stop is activated  The control system is switched on  Program switch KT on Automatic 1 ...