Download Print this page

Conversion Procedure - Smeg WD1160 Technical Instructions

Power connection conversion instruction
Hide thumbs Also See for WD1160:

Advertisement

3

CONVERSION PROCEDURE

WARNING
Before performing any operation, disconnect the device from the electricity and water supplies and make sure that
there is enough space in front of the device - at least 1m
ILLUSTRATION
0160, 1160, 4060, 4190
2
.
1. Remove the bottom door (or "bottom plinth"). Undo
the screws at the sides which secure the bottom door.
2. Disconnect the earth wire fixed to the left-hand corner
of the part and pull the door outward.
3. Remove the "drip guard".
. Undo the fixing screws at the sides
. Lift up the bottom edge of the guard and pull it
outward
4. This gives access to the components on the front cross-
bar;
in particular, you will need to work on:
. power cable
. fuse terminal clamps (for 1160 and 4060)
. wires connecting the fuse terminal clamps to the
power supply terminal board
. power supply terminal board connections
. jumpers on voltage change terminal board
Power Connection Conversion instruction
PROCEDURE
Page 5 - 9

Advertisement

loading

This manual is also suitable for:

Wd4190Wd4060Gw0160Gw4060Gw1160Gw4190