Ramsond Celiera AS-09TR3SVDDH Service Manual page 5

Table of Contents

Advertisement

› When Transporting:
Be careful when picking up and moving indoor and outdoor units. Get a partner to help, and bend your knees when
lifting to reduce strain on your back. Watch for sharp edges or thin aluminum fins, as they can cut your fingers.
› When Installing:
● In a Ceiling or Wall
Make sure the ceiling/wall is strong enough to hold the unit's weight. It may be necessary to reinforce it using a strong
wood or metal frame to provide added support.
● In a Room
Properly insulate any tubing run inside a room to prevent "sweating" - condensation that can collect and drip, leading to
possible water damage to walls and floors.
● In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents
water damage and unwanted vibration.
● In an Area with High Winds
Securely anchor the outdoor unit down with bolts and additional framing (not supplied). Provide a suitable air baffle.
● In a Snowy Area (for Heat Pump-type Systems)
Install the outdoor unit on a raised platform that will be higher than drifting snow. Provide snow vents.
› When Connecting Refrigerant Tubing:
△ Use flare method for connecting tubing.
△ Apply refrigerant lubricant to matching surfaces of the flare and union tubes before connecting them, then tighten the
nut with a torque wrench for leak-free connection.
△ Check carefully for leaks before starting a test run.
› When Servicing:
△ Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and
wiring.
△ Keep your fingers and clothing away from any moving parts.
△ Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside
the unit being serviced.
› Others:
△ Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas - on contact
with fire or heat - can produce dangerously toxic gas.
△ Confirm upon completing installation that no refrigerant gas is leaking. As stated above, if escaped gas comes in
contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas.
NOTE:
The figure, size, and parameters of the actual product may not be identical with the service manual;
please take actual product as the standard where applicable.