PA L E R T A N D P X - 0 1 S Y S T E M S W E B
C O N F I G U R AT I O N

USER MANUAL

Version 2
26/01/2018
Status: Released

Advertisement

Table of Contents
loading

Summary of Contents for JenLogix Palert PX-01 Series

  • Page 1: User Manual

    Jenlogix Ltd Unit 11, 250 Marua Rd Mt Wellington, Auckland 1051 PO Box 87131 Meadowbank Auckland 1742 New Zealand Phone: +64 9 579 6439 Fax: +64 9 820 9447 www.jenlogix.co.nz PA L E R T A N D P X - 0 1 S Y S T E M S W E B...
  • Page 2: Table Of Contents

    © Jenlogix Ltd 2018. All rights reserved. This document remains property of Jenlogix Ltd and is not to be given to any unauthorised individual, vendor or company or any copies of duplicates made without express written permission of Jenlogix Ltd. The information in this document is subject to change without notice and should not be construed as a commitment by Jenlogix Ltd.
  • Page 3: Document Conventions

    Document Stored as Z:\Supplier Brochures and promo\San Lien\Manuals etc\Palert System Web User Manual V2.docx Last Saved at 26/01/2018 10:09 AM DOCUMENT CONVENTIONS INTENDED AUDIENCE AND READING SUGGESTIONS User and administrators of Palert system USER MANUAL Version 2 26/01/2018 Page 1 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 4: 1. Palert And Px-01 Systems

    The systems come with 3 main passwords. 2 are for the web interface and 1 for the operating system. To change the web interface see next section and to change the Linux password see section Access Operating System USER MANUAL Version 2 26/01/2018 Page 2 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 5: 2. Web Interface For Software Configuration

    IP to connect subsequently. Connecting to a Palert from a local PC: Click the network connection icon. Open Network and Sharing Centre. USER MANUAL Version 2 26/01/2018 Page 3 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 6 C O N F I G U R A T I O N Click Local Area Connection > then Properties > IPv4 Change your computer IP subnet to the same as the Unit E.g. 192.168.255.xxx USER MANUAL Version 2 26/01/2018 Page 4 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 7: 3. Web Interface

    There is also an Admin user that shows up the system parmeters page. If the tab is not available then please login using this administration user. User: admin Password: 1111 USER MANUAL Version 2 26/01/2018 Page 5 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 8: Menu

    • Palert+ STD • Palert+ RSHD • Palert+ DIN • PX-01 The PX-01 netxx devices - TBA 3.2.1 PALERT+ STD, W EB INTERFACE MENU USER MANUAL Version 2 26/01/2018 Page 6 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 9 P A L E R T A N D P X - 0 1 S Y S T E M S W E B C O N F I G U R A T I O N 3.2.2 PALERT + RSHD, W EB INTERFACE MENU USER MANUAL Version 2 26/01/2018 Page 7 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 10 P A L E R T A N D P X - 0 1 S Y S T E M S W E B C O N F I G U R A T I O N 3.2.3 PALERT + DIN, W EB INTERFACE MENU USER MANUAL Version 2 26/01/2018 Page 8 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 11 P A L E R T A N D P X - 0 1 S Y S T E M S W E B C O N F I G U R A T I O N 3.2.4 PX-01, W EB INTERFACE MENU USER MANUAL Version 2 26/01/2018 Page 9 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 12: Netw Ork Settings

    This screen provides the ability to change the IP address of the unit. Once changed you may need to reset the subnet of the PC connection to continue. USER MANUAL Version 2 26/01/2018 Page 10 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 13: Reset Passw Ord

    C O N F I G U R A T I O N RESET PASSW ORD To change the web password, go to edit password tab and set as required. USER MANUAL Version 2 26/01/2018 Page 11 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 14: Setting The Ntp Server

    This is required to ensure the time stamp is kept correct. If the unit cannot connect to an NTP server, i.e. is not on a network, then the timestamp of the data will be based on the internal clock. Multiple NTP servers can be configured. USER MANUAL Version 2 26/01/2018 Page 12 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 15: Dns Settings

    P A L E R T A N D P X - 0 1 S Y S T E M S W E B C O N F I G U R A T I O N DNS SETTINGS USER MANUAL Version 2 26/01/2018 Page 13 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 16: Set Information Tab

    C O N F I G U R A T I O N SET INFORMATION TAB To change S/N of Unit use this tab – this should not need to be changed unless directed. USER MANUAL Version 2 26/01/2018 Page 14 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 17: File Tab

    C O N F I G U R A T I O N FILE TAB This enables file upload and download of configuration information, preloading of settings. USER MANUAL Version 2 26/01/2018 Page 15 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 18: Dow Nloading Event Fi Les

    For any event the system will store a csv file containing details of movement in the 3 axes. To copy any file, go to Manage Events tab, then click on any event file to download. USER MANUAL Version 2 26/01/2018 Page 16 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 19: E C O R D F I L E S

    To view event files directly from web interface: 3.11 STREAMING To check waveforms for all three axis it is possible to stream data. In addition this can be recorded for a specific time. USER MANUAL Version 2 26/01/2018 Page 17 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 20 C O N F I G U R A T I O N 3.12 PARAMETERS SETTING T AB The Parameters menu option is only available to the admin user. USER MANUAL Version 2 26/01/2018 Page 18 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 21: I N R E P O R T S

    Din provides details about vibration effects. There are 2 differnet reports – one a daily record and one a specific record. Examples shown below 3.13.1 DIN REPORT USER MANUAL Version 2 26/01/2018 Page 19 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 22 P A L E R T A N D P X - 0 1 S Y S T E M S W E B C O N F I G U R A T I O N 3.13.2 DIN EVENT USER MANUAL Version 2 26/01/2018 Page 20 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 23 C O N F I G U R A T I O N 3.14 ISO REPORT Shows vibrsation against the various standards of the ISO system both horizontal and vertical. USER MANUAL Version 2 26/01/2018 Page 21 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 24: Dort Report

    DORTS is the Dept of Rapid Transport Systems in Taipei and is similar to ISO This shows various frequency plots 2/4/8/16/31.5/63 Hz, with multiple axis …………..etc. USER MANUAL Version 2 26/01/2018 Page 22 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 25: Parameters Description

    YES / NO. Station naming parameters for use with miniSeed file format especially STATION_NET Which network is the unit part of. E.g. NZ STATION_NAME Station name. USER MANUAL Version 2 26/01/2018 Page 23 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 26 P-wave Pd displacement (cm) Alert threshold Default 0.2 PD_WARNING_THRESHOLD P-wave Pd displacement (cm) Warning threshold Default 0.35 PGA_TRIG_ENABLE Use PGA to trigger event YES / NO PGA_WATCH_THRESHOLD PGA (gal) watch threshold USER MANUAL Version 2 26/01/2018 Page 24 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 27 LCD_BACK_LIGHT_SECOND Length of time backlight stays on POWEROFF_SECONDS_TO_CPU Length of time power remains to CPU on power off CPU_STATUS_DISPLAY_INTERVAL Length of time between CPU status displays USER MANUAL Version 2 26/01/2018 Page 25 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 28 ERR_IF_TIME_NOT_SYNC RTC_TO_SYSTEM_TIME ![GEOPHONE] Uncomment if using GEOPHONE COMPENSATION [DISK_MIN_SPACE] 260000 [BACKUP_IP] [RESTORE_IP_WHILE_IP_ERROR] [LCD_RW_PIN_ENABLE] Commented out optionally DIN VERSION CONFIG ONLY: [GEOPHONE] !FREQ_START !FREQ_STOP !FREQ_STEP !0.1 !G_START USER MANUAL Version 2 26/01/2018 Page 26 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 29 RECORD_ALWAYS WARNING_DB PGA_RELAY RELAY1_ON MAXIMUM_LATCH To keep traffic light display on or auto off after 15 seconds YES/NO !ADMIN_SERVER_IP DORTS VERSION CONFIG ONLY: [DORTS_VIBRATION] BUILDING_TYPE WARNING_DB USER MANUAL Version 2 26/01/2018 Page 27 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 30 PALERT IP Add 1 or multiple Palert or Palert+ IP. MESSAGE PALERT Which one will be the main Palert out of M Starting from 0 – M. USER MANUAL Version 2 26/01/2018 Page 28 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 31 Relay 1 trigger intensity threshold. EEWS RELAY2 INTENSITY Relay 2 trigger intensity threshold. EEWS RELAY3 INTENSITY Relay 3 trigger intensity threshold. EEWS_HOLD_SECONDS Keep alarm status after countdown USER MANUAL Version 2 26/01/2018 Page 29 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 32 In addition to local warnings and regional warnings, Palert + can be used as an MQTT publisher, with the earthquake warning message being shared to subscribers. USER MANUAL Version 2 26/01/2018 Page 30 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 33 Pressing the power key for 4 Seconds enters test mode 0 RELAY_HOLD_SECOND -5570590 5570590 = 0x0055001e 55-> 85 gal, 1e-> 30 seconds PLAY_FILE 2.wav Play audio files2.wav RELAY2 ON Drive RELAY2 USER MANUAL Version 2 26/01/2018 Page 31 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 34 PLAY_FILE eewsCancel.wav Plays audio files eewsCancel.wav.. 4.1.8 FTP CONFIG Unit firmware update function, generally do not need to modify. FTP Server IP PORT FTP Server port USER MANUAL Version 2 26/01/2018 Page 32 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 35: S O R E P O R

    After the end of the event, driving API, Upload event with record function. 4.1.12 UPLOAD AN EVENT RECO RD [VWHUB_CONFIG] Upload an event record set parameter FTPIP FTP server IP USER MANUAL Version 2 26/01/2018 Page 33 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 36 FTP server user Password 4.1.13 UPLOAD AN EVENT RECO RD If it’s set, the device will be through UDP Broadcast [BROADCAST_PORT_INTERFACE] transmission port area message, by default502. USER MANUAL Version 2 26/01/2018 Page 34 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 37: A C C E S S O P E R A T I N G S Y S T E

    Then enter new password twice. This will need to be failry complex and not similar to previous as there are password policies embedded in the system. Type exit to leave system USER MANUAL Version 2 26/01/2018 Page 35 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 38: C H A N G E V O I C E A L A R M

    Optionally user can record their own voice alarms to replace the existing files using same file names. e.g. .wav file used for Intensity now are named Intensity_x.wav where x is 1 to 12. USER MANUAL Version 2 26/01/2018 Page 36 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 39: C O N T R O L B U T T O

    11. N/A 12. Shutdown The position of the boxes BOOT INTERNAL DISPLA Y BOOT COMPLETE The second line of the display will cycle through various information. USER MANUAL Version 2 26/01/2018 Page 37 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 40: Options

    C O N F I G U R A T I O N OPTIONS Press and hold the control button (2) to perform the functions below: CUBE PALERT+ PX-01 USER MANUAL Version 2 26/01/2018 Page 38 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 41 P A L E R T A N D P X - 0 1 S Y S T E M S W E B C O N F I G U R A T I O N 7.3.1 HOLD FOR 1 SECONDS. DISPLAY IP USER MANUAL Version 2 26/01/2018 Page 39 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 42 C O N F I G U R A T I O N 7.3.2 HOLD FOR 2 SEC. RESTART NTP 7.3.3 HOLD FOR 3 SEC. RESET W ARNING USER MANUAL Version 2 26/01/2018 Page 40 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 43 HOLD FOR 4 SEC. RELO AD CONFIGURATION PAR AMETERS 7.3.5 HOLD FOR 5 SECS. TEST MODE CONFIG ST ATUS 7.3.6 HOLD FOR 6 SECS • No function. USER MANUAL Version 2 26/01/2018 Page 41 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 44 HOLD FOR 7 SECS. USE FTP UPDATE 7.3.8 HOLD FOR 8 SECS. • No function. 7.3.9 HOLD FOR 9 SECS. ENT ER TEST MODE ** This is for engineer usage only ** USER MANUAL Version 2 26/01/2018 Page 42 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 45 7.3.12 HOLD FOR 1 2 SECS TO SHUT DOW N. ** After selecting this option, the power must to be turned off to allow the system to be properly restarted later ** USER MANUAL Version 2 26/01/2018 Page 43 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 46 P A L E R T A N D P X - 0 1 S Y S T E M S W E B C O N F I G U R A T I O N USER MANUAL Version 2 26/01/2018 Page 44 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 47: M O D B U S R E G I S T E R

    0 ~ 4 [bit mapping] connection status of ba host [bit mapping] high nibble for zt2000 low nibble for ba host Register Description Note________________________________ USER MANUAL Version 2 26/01/2018 Page 45 of 46 © Jenlogix 2017 Jenlogix Jenlogix...
  • Page 48 3000 ~ 3100 Palert2 packet header 4000 ~ 4100 Palert3 packet header 5000 ~ 5100 Palert4 packet header please refer to Palert manual for contents of streaming packet USER MANUAL Version 2 26/01/2018 Page 46 of 46 © Jenlogix 2017 Jenlogix Jenlogix...

This manual is also suitable for:

Px-01 controllerPx-01 netrelayPx-01 nettowerPx-01 netspeakerPalert+ s3Palert+ ... Show all

Table of Contents