Communication Parameters; Pin Assignment; Communication Data Format - Sony FWD-50PX3 Protocol Manual

Flat wide display monitor
Hide thumbs Also See for FWD-50PX3:
Table of Contents

Advertisement

1. Communication Parameters

Communication method
Synchronous method
Baud rate
Character length
Parity
Start bit length
Stop bit length
Flow control

2. Pin Assignment

Monitor side (D-sub 9-pin)
5
4
3
2
1
9
8
7
6
_ External view _
Pin No.
Function
1
NC
2
TXD
3
RXD
4
NC
5
GND
6
NC
7
NC
8
NC
9
NC
FWD-50PX3
RS-232C
Asynchronous
9600bps
8bit
None
1bit
1bit
None
Host side (D-sub 9-pin)
5
4
3
2
1
9
8
7
6
_ External view _
Pin No.
Function
1
NC
2
RXD
3
TXD
4
NC
5
GND
6
NC
7
NC
8
NC
9
NC

3. Communication Data Format

(a) Control message
No.
Item
1
Header
2
Category
3
Function
4
Data1 (Length)
5
Data2 (Data1)
:
:
:
:
X
DataX
X+1
Check Sum
* Check Sum: Sum total of 1 to X. Lower one-byte data is validated when a
value exceeds 255 (1byte).
* Set the command interval to 500 ms or more when transmitting the
Control command continuously.
* Set the command interval to 500 ms or more when transmitting the same
command (Enquiry) after the Control command.
(b) Enquiry message
No.
Item
1
Header
2
Category
3
Function
4
Data1
5
Data2
6
Check Sum
* Check Sum: Sum total of 1 to X. Lower one-byte data is validated when a
value exceeds 255 (1byte).
Value
0x8C: Control
0xXX
0xXX
0xXX
0xXX
0xXX
0xXX
0xXX
0xXX
Value
0x83: Enquiry
0xXX
0xXX
0xFF
0xFF
0xXX
1