The Via Lock operates with 125 kHz HID and AWID cards and supports all Wiegand formats up to 64 bits. Locks communicate wirelessly to a Via Hub which can be located up to 70/170 ft (21/52 m) away in a typical office environment. Each Hub can support two Via Locks.
• Installation manual • 15 screws S1 - S4: For Via Reader back plate (4) S5 - S8: For Via Control Unit back plate (4) S9, S10: For Via Reader (2) S11 - S13: For Via Control Unit PCB (3)
Via Reader…………………………………………………………………………… 2.24” (L) x 3.5” (H) x 0.79” (D) ...........…………………………………… [57 mm (L) x 89 mm (H) x 20 mm (D)] Via Control Unit........………………......3” (L) x 5.2” (H) x 1.5” (D) ..........…………………………………... [77 mm (L) x 133 mm (H) x 38 mm (D)] Weight Via Reader ....…………………………................68 g [2.4 oz]...
Cut out jamb ∕ ” (2.4mm) deep or until strike flush NOTE: LATCH BOLT BEVEL MUST FACE TO CLOSING with jamb. Tighten screws securely. DIRECTION. Via Wireless Lock Page Installation Manual July 2018 • Rev. 1.3...
Put the catch tool into the allocated position of as illustrated. outside mounting plate as the illustration below. Rotate outside mounting plate to required door thickness by using a catch tool. Via Wireless Lock Page Installation Manual July 2018 • Rev. 1.3...
Con- firm lever is secured. Install Door Contact 15. INSTALL DOOR CONTACT (INCLUDED) 24” (609mm) Figure 2: Install Door Contact Via Wireless Lock Page Installation Manual July 2018 • Rev. 1.3...
Install Via Reader back plate and secure using 4 screws (S1-S4). b. Install Via Reader and secure with 2 screws (S9, S10). Make sure the reader is securely snapped onto the back plate by pressing it firmly in place.
Switches B1-B6 are used to set a Network ID which can be from 1 to 63 and must match the Net- work ID of the Via Hub with which this lock will communicate. Do not duplicate Via Hub Network IDs unless they are well out of the range of each other (500 feet should be safe). This switch is ori- ented vertically.
Page 12
ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) Via Wireless Lock Page Installation Manual July 2018 • Rev. 1.3...
Page 13
ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) ON (DOWN) Via Wireless Lock Page Installation Manual July 2018 • Rev. 1.3...
Page 14
WIEGAND UNIT ID: 2 LOCK RELAY NET ID: 10 +12 VDC FROM ACCESS CONTROL PANEL NOTE: See Via Hub installation manual for Net ID configurations ANY ACCESS CONTROL PANEL UNIT ID: 1 FORCED ENTRY OUTPUT NET ID: 63* NET ID:...
Page 15
POWER LEVEL SETTING STRATEGY By default, the power levels for the Via Lock and Via Hub are set to LOW. This provides a range of approx. 70’ range in a typical office environment. When the power level of the Via Lock and Hub are BOTH set to HIGH, this range is extended to approx.
DIP switch is returned to the RUN position (DOWN/OFF) and the reset switch is pressed again. The Via Lock will then attempt to connect to it’s assigned Via Hub. You can verify that it is con- nected by operating the inside lever. If the event is detected and successfully transmitted to the Hub, the blue Connection Status LED in the top left corner of the controller board will blink once.
Install Via Control Unit 18. INSTALL VIA CONTROL UNIT CONTROL UNIT BACK PLATE a. Install Via Control Unit back plate and secure using 4 screws (S5-S8). b. Install Via Control Unit PCB and secure using 3 screws (S11-S13). c. Install cover using 2 screws (S14, S15).
Print dialog box, click Size and then specify the “Actual size” option. • Use a ruler to check the measurements before the templates are used. Figure 8: Print Dialog Box Settings DOOR LOCK TEMPLATE Via Wireless Lock Page Installation Manual July 2018 • Rev. 1.3...
ø 1” (25.4mm) PILOT HOLE PILOT HOLE FOR READER FOR READER MOUNTING SCREWS MOUNTING SCREWS ø ø 0.1” (2.5mm) 0.1” (2.5mm) ø 1” (25.4mm) HOLE CENTERS FOR DOOR THICKNESSES Via Wireless Lock Page Installation Manual July 2018 • Rev. 1.3...
FOR CONTROL UNIT FOR CONTROL UNIT MOUNTING SCREWS MOUNTING SCREWS ø ø 0.1” (2.5mm) 0.1” (2.5mm) ø 1” (25.4mm) PILOT HOLE CONTROL UNIT MOUNTING SCREWS ø 0.1” (2.5mm) ø 1” (25.4mm) Via Wireless Lock Page Installation Manual July 2018 • Rev. 1.3...