  • Page 1 MX2N series HMI PLC all in one programming manual Coolmay MX2N series HMI PLC all in one programming manual Copy right: Shenzhen Coolmay Technology Co.,Ltd V8.12.1...
  • Page 2: Table Of Contents

    11.1.1 Touch Panel Software installation ..............36 11.1.2 New build touch panel program ..............36 11.2 Touch panel screen download (don't support U disk download) ......37 11.3 Other HMI software usage, refer to《CoolMay HMI series user manual》..39...
  • Page 3: Summary

    MX2N series HMI PLC all in one programming manual 1 Summary 1.1 COOLMAY MX2N PLC main advantage ◆ Could use GX Developer and GX Works2 software to program,read,download, verify, diagnose,monitor and process sequence. ◆ Could customize 12 channels AD and 2 channels DA,in 12bit precision,use RD3A to read AD data and WRA3 to output DA data (can set upper and lower limit ranges.)
  • Page 4: Type & Specification

    MX2N series HMI PLC all in one programming manual cumulative time limit. ◆ Support function of NTC thermistor to measure temperature,support NTC of 10K,50K,B value of 3950. ◆ Support optional digital tube display function, support 24keys input,10 common positive digital display,you can choose dingle and double bits display,or whether to decode the display.
  • Page 5 Software Compatible with MITSUBISHI GX8.52 and WORKS2 Regular Models:MX2N-43HB-16MR/24MR/24MT(-4AD2DA-232H) MX2N-70HB-44MR/44MT(-8AD2DA-485P/232H) 485P= PLC to add 485;485H/232H= HMI to add 485/232 Detailed info. refer to: <Coolmay MX2N Series PLC Programming Manual> <HMI PLC All In One User Manual> <Coolmay HMI User Manual>...
  • Page 6: Hardware Description

    MX2N series HMI PLC all in one programming manual 1.3 Hardware description 1.3.1 MX2N-43HB structure description and dimension PLC Run light Com port of plc and hmi Power light * Dimension(mm):134*102*30 * Cutout size(mm): 119*93 * Installation: Clip installation * Display size(mm): 97*56...
  • Page 7: Mx2N-70Hb Structure Description And Dimension

    MX2N series HMI PLC all in one programming manual 1.3.2 MX2N-70HB structure description and dimension * Dimension(mm):212×148×40 * Cutout size(mm): 194×138 * Installation: Clip installation * Display size(mm): 154×87...
  • Page 8: Interface And Indicators Description

    MX2N series HMI PLC all in one programming manual 1.3.3 Interface and Indicators description POWER:Power indicator, light on when connected to power RUN:PLC operating status indicator, the lamp is on when PLC is running COM:Touch screen and PLC communication status indicator, light on when...
  • Page 9: Component Range

    MX2N series HMI PLC all in one programming manual 2 Component Range Input X X0~X47 40 points Out put Y Y0~Y47 40 points M0~M38 Ministrant 3 384 M384~M1535 1052 points M8000~M8255 255 relay M points (keep) points (special) (general) State relay...
  • Page 10: Plc Supported Instruction

    MX2N series HMI PLC all in one programming manual 3 PLC Supported instruction 3.1 Basic Logic instructions ●The program step for soft element Y and general M is 1,for S and special auxiliary relay M,timer T,counter C is 2,for Data register D ,index register V and Z is 3.
  • Page 11: Function Instruction Table( Compared With Mitsubishi Plc)

    MX2N series HMI PLC all in one programming manual Memory read Memory read and reset Inversion of operation result Y,M(Exclude Rising edge differential output Special M) Y,M(Exclude Falling edge differential output Special M) 32-bit counter:5 Counter coils drive 16- bit counter:3 Y,M:1...
  • Page 12 MX2N series HMI PLC all in one programming manual NEXT Cycle range end ★ Comparison ★ Region comparison ★ Transfer ★ SMOV Shift Transfer ★ Reverse transfer ★ BMOV Transfer together ★ FMOV Multi-casting ★ Exchange ★ BCD exchange ★...
  • Page 13 MX2N series HMI PLC all in one programming manual Input and output refresh ★ REFF Input refresh (with filter settings Matrix input HSCS Compare High speed counting set HSCR Compare High speed counting reset Compare high speed counting zone Pulse density ★...
  • Page 14 MX2N series HMI PLC all in one programming manual DECMP Binary floating point comparison ★ DEZCP Binary floating point zone comparison ★ DEBCD Binary floating point-decimal ★ DEBIN Decimal floating point-binary ★ DEADD Binary floating point addition ★ DESUB Binary floating point subtraction ★...
  • Page 15: Special Relay & Register Function

    MX2N series HMI PLC all in one programming manual AND﹤ (Sl)<(S2) ★ AND◇ (Sl)◇(S2) ★ AND≥ (Sl)≥(S2) ★ AND≤ (Sl)≤(S2) ★ (Sl)=(S2) ★ OR﹥ (Sl)>(S2) ★ OR﹤ (Sl)<(S2) ★ OR◇ (Sl)◇(S2) ★ OR≥ (Sl)≥(S2) ★ OR≤ (Sl)≤(S2) ★ Note : **1--When set analog input and output,read wrote data;...
  • Page 16 MX2N series HMI PLC all in one programming manual timeout flag ZRN Instruction clear output is M8014 M8140 1m clock pulse valid M8015 Set clock M8145 Prohibit Y0 pulse output M8016 M8146 Clock display stopped Prohibit Y1 pulse output M8017 M8147 Clock ±30 s correction...
  • Page 17 MX2N series HMI PLC all in one programming manual Content Content Monitor timer setting Series 2 communication D8000 D8120 (Default 200) parameter settings MODBUS RTU of series 2 slave D8005 Low random number 16 bits D8121 station(1~255) RS Remaining numbers...
  • Page 18 MX2N series HMI PLC all in one programming manual (Unit: 1ms, Default 0) D8040- Shared register D8152 1st to 8th activity STL status D8047 number(1~32, Default:8) CAN Communication baud rate D8049 Minimum activity STL status D8153 (20K~100K, Default:250K) D8058 D8154...
  • Page 19 MX2N series HMI PLC all in one programming manual D8116 D8195 V7 Address register contents CAN Slave can't communicate D8117 D8196 1~16 CAN Slave can't communicate D8118 D8197 17~32 CAN Slave summary no D8119 D8198 communicate 1~16 CAN Slave summary no...
  • Page 20: Analog Usage

    MX2N series HMI PLC all in one programming manual 4 Analog Usage 4.1 Analog input type Register Accuracy Input signal type Range Resolution reading value total range E type thermocouple Environment Room 0.1℃ temperature temperature~5 ~599.9℃ K type Environment Room 0.1℃...
  • Page 21: Analog Output Type

    MX2N series HMI PLC all in one programming manual Thermocouple analog reading register: Register reading value channel D8094 channel D8095 Cold junction temperature D8093 Thermocouple sampling filter times D8090(0-22,Default 0) Calculate the input voltage formula: Measure voltage = D803n (n = 0-11) * (VRF reference voltage / 4095);...
  • Page 22: Random Number Instructions

    MX2N series HMI PLC all in one programming manual 5 Random number instructions 1) Random number related register: Start convert relay-M8005 Random number save register-D8005 (low) D8006 (high) 2) If you need to generate the random number, just need to set M8005 ON in the program.
  • Page 23: High Speed Counter Application

    MX2N series HMI PLC all in one programming manual 6 High speed counter application Counter Input assigned Counter Type Model X000 X001 X002 X003 X004 X005 X006 X007 C235 C236 C237 C238 Single Phase C239 single count C240 input C241...
  • Page 24: High Speed Count Input Instructions

    MX2N series HMI PLC all in one programming manual ● The input X000~X007 cannot be reused. For example, once C251 is used, X000 and X001 are occupied, so C235, C236, C241, C244, C246, C247, C249, C252, C254 and interrupt input pointers *I00, *I01 and corresponding input SPD instructions cannot be used.
  • Page 25: Pulse Capture Function Application

    MX2N series HMI PLC all in one programming manual 7 Pulse capture function application 1) Supports the pulse capture function of X0-X5, corresponding to: X0-M8170, X1-M8171, X2-M8172, X3-M8173, X4-M8174, X5-M8175. 2) Using the pulse capture function, you need to use the EI instruction first. The example is...
  • Page 26: High Speed Pulse Output Application

    MX2N series HMI PLC all in one programming manual 8 High speed pulse output application 1) Normally with two high-speed pulses (Y0 and Y1), pulse transmission single channel maximum frequency: 100Khz, dual channel maximum: 30Khz; maximum optional four-way high-speed pulse, Y0 and Y1 can output 200KHZ at the same time, Y2 and Y3 can output 100KHz at the same time;...
  • Page 27: Mx2N-70Hb Optional Com Port Instructions

    MX2N series HMI PLC all in one programming manual 9 MX2N-70HB Optional com port instructions 9.1 Function Description 1) MX2N-70HB supports the optional 1 RS485 communication port, but can not coexist with its own 232 port. 2) Support exchange between Mitsubishi programming protocol and MODBUS-RTU protocol.
  • Page 28: D8120 Parameter And Function Setting

    MX2N series HMI PLC all in one programming manual D8126-Respond overtime(1=1ms,Default 5ms) Note: 1.M8121, M8122, M8123, M8124 are only for internal use. Don’t write to the MODBUS-RTU master when using it. 2.When D8129 receives the timeout, please set according to the actual setting. When the setting time is too long, if there is a slave communication failure, the waiting time for re-communication (namely D8129) will be very long.
  • Page 29: Modbus-Rtu Master Station Instructions

    Such as: H301-command 03 (read register instruction), slave address 01; if the high 8 bit is 0, then the command is default as 03; M2--slave element address; (Slave address of MX2N series PLC refers to slave element address table); D - master station data register, this register holds the data which read from the slave station;...
  • Page 30: Modbus-Rtu Protocol Slave Station Element Address

    MX2N series HMI PLC all in one programming manual are executed at the same time, the system will communicate in turns. If the communication is overtime, M8129 turns ON and reports 6306 fault and exits this communication, and records this overtime station number in the D8122 register,execute the next communication instructions;...
  • Page 31 MX2N series HMI PLC all in one programming manual Addres component D0-D5999 0-5999 8000-8 T0-T255 8300-8 C0-C255 Communication parameters: 1. Communication parameters,refer to above D8120; 2. Inspection: N or O or E; 3. Data bit: 8 or 7; 4. Stop bit: 1 or 2;...
  • Page 32: Rs Protocol Special Registers & Relays Instructions

    MX2N series HMI PLC all in one programming manual instruction: 03,04; 4, Write register instructions: 06; 5, Write multi-bit register instructions: 16 (H10) Note: The maximum registers could be written and read at the same time is 64. 9.6 RS Protocol special registers & relays instructions M8121:RS instruction is being sent...
  • Page 33: Fault Detection

    MX2N series HMI PLC all in one programming manual 10.Fault detection Sorts Error Error contents Resolution 0000 No abnormality Check the power failure detection PLC hardware 6101 Power failure data error circuit, CPU internal FLASH is error damaged Increase D8000 setting value, or...
  • Page 34 MX2N series HMI PLC all in one programming manual MODBUS master function is not opened on using Please enable the MODBUS 6410 TO/FROM instruction master function in the setup Using the RD3A/WR3A instructions can’t open Please enable AD/DA 6411 AD/DA enhancement function...
  • Page 35 MX2N series HMI PLC all in one programming manual Note: When the power is turned off, the ERR light is on and the program is not allowed to be downloaded. **If you need to reset the ERR light, after troubleshooting: 1.
  • Page 36: Hmi (Human Machine Interface)

    MX2N series HMI PLC all in one programming manual 11 HMI (Human Machine Interface) 11.1 Touch Panel Software instruction 11.1.1 Touch Panel Software installation CoolMay HMI touch panel software,compatible with XP/WIN7/WIN8/WIN10 system, If failed installation, try to change computer,reset system,and permit higher user rights to correct the fault.
  • Page 37: Touch Panel Screen Download (Don't Support U Disk Download)

    MX2N series HMI PLC all in one programming manual * MX2N-70HB,select MT6070H(800*480) 11.2 Touch panel screen download (don't support U disk download) 1.Use USB downloading cable to download the program,and save it, click “application”- -”compile”(F5); After compiling, it will show “ Create file success”;...
  • Page 38 MX2N series HMI PLC all in one programming manual 2.In the target file path (as picture show) to see the default disk,usually C drive) Confirm C drive generate a file in same name with the program and format”***.hw6” (As picture,”T480272.hw6”)
  • Page 39: Other Hmi Software Usage, Refer To《Coolmay Hmi Series User Manual

    MX2N series HMI PLC all in one programming manual 4.downloading window will appear, waiting until that HMI connection is ok,IP setting is OK, then click “Download” when you get the prompt ; 5. It will prompt “Update success!” after download completed.