This document shows how to install and use the charge station Chargestorm Connected.
Figure 1 Chargestorm Connected
The manual is valid for the Chargestorm Connected family. Model information is found on the top of
the technical box. For a complete list of article numbers, please download datasheet at
http://www.chargestorm.se
2
Safety
ü Only accredited electrician is allowed to perform the installation described in this document
ü Read and follow the instructions in this document before installation and usage of the product
ü Installation must fulfill local safety regulations
3
Delivery content
Part of delivery
ü The charging station
ü Installation and user manual
ü Two keys
ü Cover for cable inlet (M32 and M12).
ü Holder for charging gun (In case charging station is equipped with fixed cable)
To bring
ü 4 pcs screws (M8) for wall mounting. Select screw type depending of wall.
ü 4 pcs of rubber seal/gaskets to use with screw. – Note very important!
ü RFID-tag (in case RFID shall be used) of type Mifare Classic/ IEC 14443 Type A. RFID-tags can
be ordered from Chargestorm web-shop (https://chargestorm.se/webbshop/)
Option
ü Pole mount kit for pole diameter 60 mm. Article number 920-00010.
Installation manual Chargestorm Connected
1) Front panel
2) Display with charging status symbols
3) Back cover
4) Technical box
5) EV connector (outlet or cable)

Advertisement

Table of Contents
loading

Summary of Contents for Chargestorm Connected

  • Page 1 5) EV connector (outlet or cable) Figure 1 Chargestorm Connected The manual is valid for the Chargestorm Connected family. Model information is found on the top of the technical box. For a complete list of article numbers, please download datasheet at http://www.chargestorm.se...
  • Page 2: Installation Location

    ü Ethernet: Network cable of type Cat5 or better shall be connected to the charging station. In case the charging station is behind a firewall and shall be connected to a backend system must DNS (port 53), https/wss (port 443) be opened in the firewall. If remote firmware upgrade shall be possible must also ftp be opened in the firewall.
  • Page 3: Installation

    RJ45 port. Cable glands shall be used to protect for dust and water penetration. More information related to load balancing is available in, ref. 2) and ref. 3). If wiring is connected from below must holes be drilled in the unit according to Figure 3.
  • Page 4 Put back protection cover and close and lock with the key. For three-phase Chargestorm Connected models with dual connectors is incoming power connected to the DIN rail mounted terminal blocks at the bottom between the connectors. Check that L1-L3, PE and N is correctly mated.
  • Page 5 Step 6) Connect network – In case Ethernet is used connect cable to RJ45-connector on the control board located on the front panel. When cable is connected in both ends shall link and activity led on the RJ45 connector be active. If 3G is in use, check that the SIM-card is installed on the modem unit on the control board.
  • Page 6: Network Settings

    5. Configure load balancing 6.1 Local web interface To connect to the local web interface shall a USB cable be connected between the computer and the controller board mini USB port. In your browser enter IP address 192.168.7.2 to reach the web interface.
  • Page 7 Installation manual Chargestorm Connected Ethernet To set the IP settings for Ethernet follow the instruction below. ¥ Under “Configuration®Interface®General”, select WAN=”Wire”. ¥ Under “Configuration®Interface®Wire”, select “DHCP” or “Static” (for Static enter IP address, netmask and gateway). For “DHCP” is IP address assigned automatically.
  • Page 8: Current Limit

    The information shall be provided by the portal operator. In case Chargestorm’s portal “Charge Portal” is used is the URL to the portal on the following format.
  • Page 9: Product Information

    Installation manual Chargestorm Connected Figure 14 Portal configuration 6.5 RFID In order to activate user authentication can RFID be used. RFID-configuration can either take place from the portal (from a browser) or be configured on local web interface. ¥ To activate RFID, navigate to ”Configuration®Outlet®Authentication” and select ”RFID” for all outlets.
  • Page 10 Installation manual Chargestorm Connected C-characteristics. Type A. Breaking capacity 6kA. Nominal current 16 or 32A Fuses depending on model. Mechanics Weight Less than 12kg (depends on model) Dimension Height: 395mm, Width: 278mm, Depth: 160mm Material Front and back cover in ABS plastic. Colored zinc oxide metal box for electronics.
  • Page 11: Warranty

    ü Control network access to back end (in case the charging station is connected) Recycling Chargestorm Connected contains electronics and shall be recycled. You can send back the charging station to Chargestorm and we will take care of the recycling. Alternatively, follow your local guide for recycling of electronics. Warranty Warranty period for Chargestorm Connected is 1 year from delivery to customer.
  • Page 12: Electrical Schematics

    Installation manual Chargestorm Connected Electrical schematics Below is an example of a schematics for Chargestorm Connected Connected (3ph dual outlet). Chargestorm AB GACELL A/S - Sletten 17 - DK 7500 Holstebro - 961 02 961...
  • Page 13 This manual is delivered “as is” and contain content that can change without prior notice. Chargestorm AB does not guarantee that everything is correct in the manual. Chargestorm AB is not responsible for faults or incidents or damages that can be traced to the usage of this manual.

Table of Contents