6.1 Default parameters

type
Model
Frequency
E32-433T30D
433MHz
6.2 Reading operating parameters
Instruction format
C1+C1+C1
6.3 Reading version number
Instruction format
C3+C3+C3
6.4 Reset command
Instruction format
C4+C4+C4
6.5 Parameter setting command
No.
Item
Fix 0xC0 or 0xC2, it means this frame data is control command
0
HEAD
Default parameter values::C0 00 00 1A 17 44
Address
Channel
0x0000
0x17
In sleep mode(M0=1,M1=1),
User gives the module instruction (HEX format): C1 C1 C1, Module
returns the present configuration parameters.
For example, C0 00 00 1A 17 44.
In sleep mode ( M0=1 , M1=1 ) ,User gives the module instruction (HEX format): C3 C3
C3,Module returns its present version number, for example C3 32 xx yy. the second bytes means
frequency. 32 here means the frequency is 433MHZ, 38 means frequency is 470MHz, 45 means
frequency is; 868MHz, 44 means the frequency is 915 MHz, 46 means the frequency is 170MHz;
xx is the version number and yy refers to the other module features.
In sleep mode(M0=1,M1=1),
User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time. During
the reset process, the module will conduct self-check, AUX outputs low level. After reset
completing, the AUX outputs high level, then the module starts to work regularly which the
working mode can be switched or be given another instruction.
Description
Air data rate
Baud rate
2.4kbps
9600
Description
Description
Description
C0:
power-down
C2: Do not save the parameters when
power-down
-10-
Transmitting power
Parity
8N1
1W
Remark
Must be 0xC0 or 0xC2
Save
the
parameters