Алексей
June 30, 2025
Как определить какой режим, мне нужен? Что означает и как включается каждый режим?
1 comments:
Mr. Anderson
August 25, 2025
The TRAMEX RWS has two modes of operation:
1. EIFS Mode (Exterior Insulation and Finish System) - Use this mode for scanning moisture in EIFS materials. - To activate: Select the MODE switch until the Yellow LED lights up.
2. Roof Mode - Use this mode for scanning moisture in roofing systems. - To activate: Select the MODE switch until the Red LED lights up.
Each mode has two sensitivity ranges:
- Low Range (Yellow LED on RANGE switch) - Suitable for smooth or mineral-surfaced roofs.
- High Range (Red LED on RANGE switch) - More sensitive; suitable for scanning through heavier membranes or dry gravel/ballast. If readings are not satisfactory through ballast, remove it and scan directly on the waterproofing surface.
To select a range, press the RANGE switch to toggle between Low and High Range.
Page 1
TROUBLESHOOTING Both LED’s flashing and meter frozen. RWS is in HOLD mode. Press HOLD button to release. Check Battery strength by pressing Audio/Battery button, checking that needle Roof and Wall Scanner reaches above Battery line on dial. USER GUIDE ONLINE...
Page 2
When HOLD button is pressed orange buttons to match the sequence to the both LED’s will flash continuously. If the RWS is key displayed on the label. Please refer to the shut down in HOLD mode it will retain the online User Guide for more information.
Need help?
Do you have a question about the RWS and is the answer not in the manual?
Questions and answers
Как определить какой режим, мне нужен? Что означает и как включается каждый режим?
The TRAMEX RWS has two modes of operation:
1. EIFS Mode (Exterior Insulation and Finish System)
- Use this mode for scanning moisture in EIFS materials.
- To activate: Select the MODE switch until the Yellow LED lights up.
2. Roof Mode
- Use this mode for scanning moisture in roofing systems.
- To activate: Select the MODE switch until the Red LED lights up.
Each mode has two sensitivity ranges:
- Low Range (Yellow LED on RANGE switch)
- Suitable for smooth or mineral-surfaced roofs.
- High Range (Red LED on RANGE switch)
- More sensitive; suitable for scanning through heavier membranes or dry gravel/ballast. If readings are not satisfactory through ballast, remove it and scan directly on the waterproofing surface.
To select a range, press the RANGE switch to toggle between Low and High Range.