Do you have a question about the Kaysun KSD-35 DVN12 and is the answer not in the manual?
Questions and answers
Summary of Contents for Frigicoll Kaysun KSD-35 DVN12
Page 1
OWNER'S MANUAL Double Flow Console KSD-35 DVN12 KSD-35 DVR12 KSD-52 DVN12 KSD-52 DVR12 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
Page 2
For R-410A For R-32 (Indoor Unit, Outdoor Unit) units units KSD-35 DVN12 (KSD-35 DR12 , KUE-35 DVN11) KSD-52 DVN12 (KSD-52 DR12 , KUE-52 DVN12) KSD-35 DVR12 (KSD-35 DR12 , KUE-35 DVR12) KSD-52 DVR12 (KSD-52 DR12 , KUE-52 DVR12)
Table of Contents Page 0. Safety Precautions ..................4 1. Indoor Unit Parts and Major Functions ............6 2. Manual Operations ..................8 3. Care and Maintenance ................. 9 Unit Maintenance How to Clean the Air Filter Repairing Refrigerant Leaks Preparation for Periods of Non-use 4.
Safety Precautions Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain, and troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of your unit. Please pay attention to the following signs: Failure to observe a warning may result in serious injuries.
Page 5
CAUTION • This appliance can be used by children aged from 8 • Do not touch the air outlet while the swing flap is in years and above and persons with reduced physical, motion. Fingers might get caught or the unit may break sensory or mental capabilities or lack of experience down.
Indoor Unit Parts and Major Functions Unit Parts Display panel Air flow louver (at air outlet) Air inlet (with air filter in it) Air flow louver (at air outlet) Refrigerant connecting pipe Drain hose Fig. 1.1 Operating Conditions Use the system under the following temperatures for safe and effective operation. If the air conditioner is used under different conditions, it may malfucntion or become less efficient.
Page 7
Features • Louver Angle Memory Function • Auto-Restart (optional) (some models) Some models are designed with a louver angle memory In case of power failure, the system will immediately function. When the unit restarts after a power failure, the stop. To restart the unit, press the ON/OFF button on angle of the horizontal louvers will automatically return the remote control.
Manual Operations Adjusting Air Flow Direction This display panel on the indoor unit can be used to operate the unit in case the remote control has been misplaced or is Manual Swing: Press Air Direction to fix the louver a out of batteries.
Care and Maintenance Safety Precautions WARNING: DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF • Contact an authorized service technician for repair or maintenance. Improper repair and maintenance may Removing and cleaning the filter can be dangerous. cause water leakage, electrical shock, or fire, and may Removal and maintenance must be performed by a certified void your warranty.
Repairing Refrigerant Leaks 3. Hold the tabs of the frame and remove the 4 claws. (The special function filter can be washed with water once every 6 months. It is recommended that you replace it WARNING once every 3 years). •...
Troubleshooting CAUTION If one of the following conditions occurs, switch off the power supply immediately and contact your dealer for further assistance. • The operation light continues to flash rapidly after the unit has been restarted. • The remote-control buttons do not work. •...
Issue Possible Causes The unit may absorb odours from the environment (such as furniture, cooking, cigarettes, The unit emits a bad etc.) which will be emitted during operations. odour The unit's filters have become moldy and should be cleaned. The fan of the outdoor During operation, the fan speed is controlled to optimize product operation.
Error Codes Error code appears and begins with the letters as the following in the window display of indoor unit: E(x), P(x), F(x) The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes.
European Disposal Guidelines Users in European Countries may be required to properly dispose of this unit. This appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law requires special collection and treatment. Do not dispose of this product as household waste or unsorted municipal waste. When disposing of this appliance, you have the following options: •...
Page 15
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version QSCONSOLE-002U 16122600000109 20190119...