I-Gard DSP-CA Instruction Manual

Cable adapter

Advertisement

Quick Links

Ground Fault Protection
DSP OHMNI Accessory:
DSP-CA(S) Cable Adapter
Instruction Manual
7615 Kimbel Street,
Mississauga,
Ontario Canada L5S 1A8
Tel: (905)673-1553
Fax: (905)673-8472
Toll Free: 1-888-RESISTR 737-4787
www.i-gard.com

Advertisement

loading

Summary of Contents for I-Gard DSP-CA

  • Page 1 Ground Fault Protection DSP OHMNI Accessory: DSP-CA(S) Cable Adapter Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR 737-4787 www.i-gard.com...
  • Page 2 1.6. The DSP-CA module is simply a junction box without switching. One of each module is required to interface the cable to the DSP Modules. Note: A DSP-CAS can be used instead of a DSP-CA if necessary, but the input terminals would have to be permanently shorted.
  • Page 3 Failure to observe these precautions may result in death or severe personal injury. 2.1. The DSP-CA(S) modules may be connected to the DSP Feeder Modules DSP-DFM by the use of either of the two ribbon cable connectors from either side as desired. See Figure 2.1 (a) and (b) 2.2.
  • Page 4 DSP-CA(S) CABLE ADAPTER April 2007 13 14 15 16 17 18 19 20 13 14 15 16 17 18 19 20 Alternate Ribbon DSP-CA Connection Ribbon to DSP- DSP-CAS Ribbon to DSP- Figure 2.1 (a) DSP-CAS Connections Figure 2.1(b) DSP-CA Connections...
  • Page 5 13 on the left side adapter (whether it be DSP-CA or DSP-CAS does not matter) and terminal 13 on the right side adapter. There should be no continuity (2 Megohms, or greater) when there is no short across terminals 1 and 2 of the DSP-CAS and when shorted there should be low resistance between the two terminals (less than 100 ohms).
  • Page 6 DSP-CA and DSP-CAS 58.00mm 70mm Figure 4.1 Dimensional Details DSP-CA(S) 5. Typical Installation Diagrams 5.1. Figures 5.1 and 5.2 illustrate the use of the DSP systems in double and triple ended substations Note the diagrams are simplified and do not show the DDR2 resistors or sensors and Trip circuit wiring, for clarity.
  • Page 7 C-415EM INSTRUCTION MANUAL DSP-CA(S) CABLE ADAPTER April 2007 N.O. Contact Shielded Cable 22 Gauge x 8 conductor Shield Screw Terminals or Connected to RJ-45 Jack Ground at one end of cable only. DSP-CA (No Switch) DSP-CAS Switch Figure 5.1 Typical Main-Tie-Main Substation with two DSP systems...
  • Page 8 C-415EM INSTRUCTION MANUAL DSP-CA(S) CABLE ADAPTER April 2007 AuxContact AuxContact DSP-CAS DSP-CAS DSP-CA DSP-CAS DSP-CA Switch Switch Switch Figure 5.2 Typical Main-Tie-Main-Tie-Main Substation with three DSP systems...
  • Page 9 Corp. Telephone: (905) 673-1553 7615 Kimbel St Unit 1 FAX: (905) 673-8472 Mississauga ON e-mail: info@i-gard.com L5S 1A8 Website: www.i-gard.com QUALITY PRODUCTS, TECHNICAL EXCELLENCE, PREMIUM SERVICE...