Advertisement

CONTROLLER
CONTROLLER
CONTROLLER
CONTROLLER
Ins
Ins
Ins
Instruction Manual
truction Manual
truction Manual
truction Manual
Model
This
This
This
This
instruction
instruction
instruction
instruction
ma
manual
ma
ma
nual
nual
nual
applies
applies
applies
applies
C10
C10
C10
C10- - - - controller
controller
controller whic
controller
whic
whic
which installs the
h installs the program
h installs the
h installs the
program
program
program
version 6 and later.
version 6
and later.
version 6
version 6
and later.
and later.
Please check the program version of your
Please check the program version of your
Please check the program version of your
Please check the program version of your
C10
C10
C10
C10- - - - controller
controller
controller
controller on the version information.
on the version information.
on the version information.
on the version information.
The controller which is installed the program
The controller which is installed the program
The controller which is installed the program
The controller which is installed the program
version
version 5 5 5 5 and later co
and later corresponds
rresponds to to to to the
the RoHS
RoHS
version
version
and later co
and later co
rresponds
rresponds
the
the
RoHS
RoHS
Directive and confirms with the CE Marking
Directive
Directive
Directive
and confirms with the CE Marking
and confirms with the CE Marking
and confirms with the CE Marking. . . .
B B B B efore use
efore use C10
efore use
efore use
C10- - - - controller
controller , please read this
, please read this
, please read this
, please read this " " " " Instruction Manual
C10
C10
controller
controller
Instructions
Instructions
Instructions
Instructions" " " " thoroughly to use it in the right way. Please keep it on file for further reference.
thoroughly to use it in the right way. Please keep it on file for further reference.
thoroughly to use it in the right way. Please keep it on file for further reference.
thoroughly to use it in the right way. Please keep it on file for further reference.
to
to
to
to
Instruction Manual" " " " including
Instruction Manual
Instruction Manual
including " " " " Safety
including
including
HTE302172
6 6 6 6
Safety
Safety
Safety
0/38
HTE302172
0/46
5
6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C10 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Sinfonia Technology C10 Series

  • Page 1 CONTROLLER CONTROLLER CONTROLLER CONTROLLER Instruction Manual truction Manual truction Manual truction Manual Model This This This This instruction instruction instruction instruction manual nual nual nual applies applies applies applies C10- - - - controller controller controller controller whic whic whic which installs the h installs the h installs the...
  • Page 2: Table Of Contents

    Introduction Introduction Introduction Introduction Thank you for buying your C10-Series controller. Before use C10-controller, please read this “Instruction Manual”, including “Safety Instructions”, thoroughly to use Safety Instructions Safety Instructions Safety Instructions Safety Instructions C10-controller safely and in the right way. Please keep it on file for further reference and/or maintenance.
  • Page 3: Safety Instructions

    Safety Instructions Safety Instructions Safety Instructions Safety Instructions -Continued- Danger Danger Danger Danger Caution Caution Caution Caution Don’t apply C10-controller to a piezo-electric type partsfeeder. Don’t use C10-controller where inflammable material exists. It has not an Please reserve maintenance space around C10-controller and partsfeeder for daily check explosion-proof structure.
  • Page 4: Wiring Connections

    Wiring Connections Wiring Connections Wiring Connections Wiring Connections ① Remove the control panel Danger Danger Danger Danger : : : : Before remove control panel, Wire the controller and a partsfeeder or a linear feeder. disconnect and lock out the power supply at the safety disconnect switch.
  • Page 5: Name And Function Of The Buttons, Lamps And Dials On The Control Panel

    How to operate the Control Pane How to operate the Control Panel How to operate the Control Pane How to operate the Control Pane How to Run and Stop the Partsfeeder How to Run and Stop the Partsfeeder How to Run and Stop the Partsfeeder How to Run and Stop the Partsfeeder : Turning on : Blinking...
  • Page 6: Basic Setting Up Procedure

    How to operate the How to operate the Control Pane How to operate the How to operate the Control Pane Control Pane Control Panel -Continued- Basic Setting up Procedure Basic Setting up Procedure Basic Setting up Procedure Basic Setting up Procedure 3.
  • Page 7: How To Adjust The Function Set Value

    How to operate the Control Pane How to operate the Control Pane How to operate the Control Pane How to operate the Control Panel -Continued- How to adjust the Function Set Valu How to adjust the Function Set Valu How to adjust the Function Set Valu How to adjust the Function Set Value e e e 1.
  • Page 8: Initial Setting

    Initial Setting Initial Setting Initial Setting Initial Setting Preparation for operation Preparation for operation Preparation for operation Preparation for operation How to adjust the Drive Frequency Output Range How to adjust the Drive Frequency Output Range How to adjust the Drive Frequency Output Range How to adjust the Drive Frequency Output Range The preparation for operation is described here.
  • Page 9: How To Adjust The Stroke On The Auto-Tuning Mode

    Initial Setting Initial Setting Initial Setting Initial Setting -Continued- How to adjust the Stroke on the auto- - - - tuning mode How to adjust the Stroke on the auto- - - - tuning mo How to adjust the Stroke on the auto How to adjust the Stroke on the auto tuning mode tuning mode de de de...
  • Page 10: How To Set The Stroke On The Constant Voltage Mode

    Initial Setting Initial Setting Initial Setting Initial Setting -Continued- How to set the stroke on the Constant Voltage Mode How to set the stroke on the Constant Voltage Mode How to set the stroke on the Constant Voltage Mode How to set the stroke on the Constant Voltage Mode Turning on 3.
  • Page 11 Initial Setting Initial Setting Initial Setting Initial Setting -Continued- Turning on 5. Dial “Selection Dial” and select “Frequency”. How to set the Stroke on How to set the Stroke on the the Constant Stroke mode Constant Stroke mode How to set the Stroke on How to set the Stroke on Constant Stroke mode Constant Stroke mode...
  • Page 12: Scaling Of The Stroke

    Initial Setting Initial Setting Initial Setting Initial Setting -Continued- Scaling of the stroke Scaling of the stroke Scaling of the stroke Scaling of the stroke Scaling of the stroke converts usable stroke range into controllable range as 0 to 100%. 5.
  • Page 13: Additional Function

    Additional Function Additional Function Additional Function Additional Function Push and hold the “Set” button more than three seconds and the minimum scaling coefficient that converts the present stroke data into just “100” appears on the display. Setting ting ting ting up for Keylock up for Keylock up for Keylock up for Keylock function...
  • Page 14: Connection Of Overflow And Stroke Sensors

    Additional Function Additional Function Additional Function Additional Function -Continued- Mounting of a stroke sensor on a partsfeeder Mounting of a stroke sensor on a partsfeeder Mounting of a stroke sensor on a partsfeeder Mounting of a stroke sensor on a partsfeeder a.
  • Page 15 Size of the stainless bar / Top and bottom Size of the stainless bar / Top and bottom Size of the stainless bar / Top and bottom Size of the stainless bar / Top and bottom Mounting of Stroke sensor on a linear feeder Mounting of Stroke sensor on a linear feeder Mounting of Stroke sensor on a linear feeder Mounting of Stroke sensor on a linear feeder...
  • Page 16: How To Use External Signal Terminals

    How to use External Signal Terminals How to use External Signal Terminals How to use External Signal Terminals How to use External Signal Terminals Operation Synchronous Signal Terminals Q1 and Q2, and AUX. OUT Operation Synchronous Signal Terminals Q1 and Q2, and AUX. OUT Operation Synchronous Signal Terminals Q1 and Q2, and AUX.
  • Page 17 Connection Diagram Connection Diagram Connection Diagram Connection Diagram 4 4 4 4 - - - - 20mA Current control / Two 20mA Current control / Two 20mA Current control / Two 20mA Current control / Two- - - - rate rate rate rate- - - - of of of of- - - - feed...
  • Page 18 Speed Change Signal Speed Change Signal Speed Change Signal Speed Change Signal How to store the Speed Change Signal How to store the Speed Change Signal How to store the Speed Change Signal How to store the Speed Change Signal Combinations of “Open”...
  • Page 19: Conformity With Ce Marking

    Conformity with CE Marking Conformity with CE Marking Conformity with CE Marking Conformity with CE Marking How to wire the How to wire the “ “ “ “ E E E E - - - - Con Con” ” ” ” connector connector How to wire the How to wire the...
  • Page 20 2. Noise filter a. The input and output power line of the controller should install noise filters In the case of two or three sets of controller are installed in the same enclosure and the mentioned below on them. power supply for them may be connected in a row, only one single phase noise filter and b.
  • Page 21: Trouble Shooting

    Function Table Function Table Function Table Function Table Trouble Shooting Trouble Shooting Trouble Shooting Trouble Shooting Function Table Function Table Function Table Function Table First Checking Item First Checking Item Remedy Remedy First Checking Item First Checking Item Remedy Remedy ●Does the resonant frequency of the partsfeeder match ●Review the function setting.
  • Page 22: How To Initialize The Settings

    Outline Dimension Outline Dimension Outline Dimension Outline Dimension C10- - - - 1VFEF,C10 1VFEF,C10- - - - 3VFEF 3VFEF 1VFEF,C10 1VFEF,C10 3VFEF 3VFEF Error Code Error Code Error Code Error Code Code Name of Code Error and Remedy E-oL The error is annunciated when output current excesses Trip by Over Current the rated current.
  • Page 23: Outline Dimensions

    Specifications Specifications Specifications Specifications Accessory Accessory Accessory Accessory List List List List Model C10-1VFEF C10-3VFEF C10-5VFEF Power Source AC200~230V±10% AC100~120V±10% 50/60Hz Control Type Model Input power 200V system Input power 100V system 0~190V( ) 0~95V( ) Manufacture Voltage When power source is AC 100V system the output voltage is 0 to 190V with an optional On C10-controller On the Load Name of Part...
  • Page 24: Guarantee

    The above obligations shall only apply to such Company name was changed from as of April 2009 defects that appear within one year as of the shipment from Sinfonia Technology co.,ltd. The one year means working 8 hours per day by 365 days per year. Tokyo Headquarters Shiba NBF Tower, 1-30, Shiba-daimon 1-chome, Minato-ku, Tokyo, 105-8564, Japan Sinfonia Technology co.,ltd shall, at its choice:...
  • Page 25 http://www.sinfo-t.jp HTE302172 47/46...

This manual is also suitable for:

C10-1vfefC10-3vfefC10-5vfef

Table of Contents

Save PDF