RVS -360-SDS Instruction Manual

360 0 ultrasonic detection sensor system for rvs-77555 360 0 hd camera system

Advertisement

Instruction Manual
360° Ultrasonic Detection Sensor System
For RVS-77555 360° HD Camera System
RVS-360-SDS
VEHICLE SAFETY -
IT'S ALL WE DO.
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RVS-360-SDS and is the answer not in the manual?

Questions and answers

Summary of Contents for RVS RVS-360-SDS

  • Page 1 Instruction Manual 360° Ultrasonic Detection Sensor System For RVS-77555 360° HD Camera System RVS-360-SDS VEHICLE SAFETY - IT'S ALL WE DO.
  • Page 2: Table Of Contents

    Contents 1. Precautions ....................1 2. Hints for Users ................... 3 3. Specifications .................... 3 4. Product Features ..................3 5. Product Installation ..................4 6. Connection ....................4 7. Troubleshooting ..................6...
  • Page 3: Precautions

    1. Precautions ● Storage and Keeping The storage temperature of this device is -40~+80℃, and the operating temperature is -20~+70 ℃. The humidity is RH90% Never use this device in environments with excessive moisture, dust or smoke. Avoid dropping or striking this device. Avoid using this device in enclosed spaces, areas with excessive vibration or subject to severe impacts.
  • Page 4 ● Maintenance Remove all the cable connections from the device before cleaning it. Clean the sensor face of any accumulation of dirt, mud, snow, ice, or debris. Visually inspect the attached wiring and cable and verify that they are properly secured and not damaged.
  • Page 5: Hints For Users

    2. Hints for Users When triggered to work, the ultrasonic obstacle detection system will start alerting after a one-second delay. If reversing at high speed, expect the ultrasonic obstacle detection system to have a one-second delay before emitting a warning. While reversing, it is indispensable to use the ultrasonic obstacle detection system.
  • Page 6: Product Installation

    5. Product Installation  1st step  Install the sensors on a suitable place. The distance between sensor S6 / S7 and S1 / S12 must be more than 1.5m, and other adjacent sensors should be installed more than 0.5m. Ideally the sensors should be installed on the vehicle at roughly 0.6m to 0.8m above the ground.
  • Page 7 461-10# cable Notice: *Most problems occurred in testing are usually caused by improper installation of the sensors, they may be solved in actual application.
  • Page 8: Troubleshooting

    7. Troubleshooting Symptoms Causes Solutions Check whether the cable is No reaction from the system while No power input properly connected with the power is on. panoramic equipment No reaction on display while there Improper connection of Check whether the connection is are obstacles within the detecting the sensor.
  • Page 9 If you have any questions about this product, contact: Rear View Safety, Inc. 1797 Atlantic Avenue Brooklyn, NY 11233 800.764.1028 Vehicle Safety - It's All We Do.

Table of Contents