Contents 1. Introduction ………………….…………………………….……..…………. 2. Caution …………………………………………………….………………….….. 3. Delivery control …………………………………………......4. Technical description ……………………….………………………….. Technical characteristics Outside Inside Explored view Wire control operation General diagram of the refrigerating circuit Safety and control systems Electric diagram 5. Installation ……………………….…………………………………..Rules of installation Hydraulic connections Electric connections Procedure of use...
Introduction We thank you for having chosen our Heat pump. This installation and maintenance notice contains the necessary information to its installation (delivery control, the installation, the connections) and to its repair. It is a complementary document to the user’s manual which describes its instructions for use. We invite you to read it first.
3- Delivery’s control At the delivery time, check the condition of packing; in case of damages, have reservation about them to the carrier, before 48 hours and by registered letter with acknowledged receipt. Before any manipulation, check the complete state of the machine. Technical description Characteristics: Unit Model ...
Outside: Fan protection grid Front panel Top cover Control panel Refrigerant pressure manometer Fast connection for water outlet Fast connection for water intlet Wire connection for power supply Inside: (Front sheet cover and panel removed) 9 Evaporator 10 Fan 11 Compressor 12 High and low pressure interruptor 13 Titanium heat exchanger 14 Temperature sensor of swimming pool water 15 Four way valve 16 Ambient temperature sensor 17 Defrost sensor 18 Water flow switch ...
Wire control operation Wire controller operation Functions of Buttons ” button “ If the machine is on, press this button to turn it off. If the machine is off, press this button to turn it on. And the TSET will be shown for 5S. Then it will show the inlet water temperature and working mode.
Page 8
“▲”“▼”button TSET setting and Lock/Unlock the screen TSET setting: Press “▲”/“▼”button, raise or reduce the TSET 1℃ by 1℃. Lock/Unlock the screen:Press “▲”and“▼”button 3 seconds, to set keylock; Press “▲” and“▼”button 3 seconds again to release keylock. “TIME”button Press “TIME” button for 3s to enter clock setting. With the function of “▲”“▼”buttons, you can set hour first.
Page 9
Light on under smart mode, machine working with the standard frequency. Light on under power mode, machine working with the high powers. Light on under silent mode, machine working with the low frequency.
General diagram of the refrigerating circuit The heat pump is reversible allowing the swimming-pool’s heating or cooling: Swimming-pool water’s heating mode: The cold and liquid refrigerant fluid absorbs the heat contained in the air through the evaporator (gilled radiator), in which it is vaporizing; it is then put up in pressure and in temperature by the compressor which sends it in the condenser (exchanger) where it loses its heat (in giving it to the water of swimming pool) and comes back in liquid state;...
Page 11
Swimming-pool water’s cooling mode: The 4 way valve reverses the circulation of the refrigerant fluid; the fluid vaporizes in the exchanger (evaporator) in getting the heat of the water, goes through in the compressor which reheats it and through in the gilled radiator (which becomes condenser) where it comes back to liquid state. Cold air Evaporator (gilled...
Safety and control systems Heat pumps are equipped with the following standard protection systems: 1. Water flow switch Thanks to this flow switch, the heat pump will not work when the filter pump is not working (and the water is not circulating). This system prevents the heat pump from heating only the water flow in the heat pump itself.
5. Anti-frost protection during winter Anti-frost protection can only be activated when the heat pump is in STAND-BY mode or shu tdown protection: 1) During standby mode, when the ambient temperature ≤5℃, First anti-frost protection activated. Water pump will run automatically each10 minutes. When the ambient temperature ≥8℃, First anti-f rost protection off.
5- Installation Rules of installation: Electric and hydraulic connections must be carried out according to standards in effect (NF C 15 100, CE I 364). The machine must be installed outside. The machine must be posed on its ant vibratory studs, set and lying flat and on a massive base (concrete slab);...
Hydraulic connections: respect imperatively Connection is carried out with a by-pass located on the circuit of filtration, upstream appliances of the Technical room chemical treatment of water. Heat Pump Connect intake/outlet water PVC pipes DN50 to the openings of the machine in following the inlet / outlet Blowing indications (grease the worms before screwing) By-pass...
Electric connections: CAUTION: before connecting the machine, make sure that the feeder is disconnected to the electrical network. The electric installation must be carried out by an experienced electrician and the supply must come from a severing equipment and differential protection; the whole must be carried out according to standards' in force in the country where the material is installed.
Procedure of use External Heat pump Appliance Action Display or Button of heat response pump Engage the circuit breaker of the heat pump Put the heat pump Display TIME under tension Engage the circuit breaker of pump of Put in circulation filtration the swimming pool water into...
6- Water Flow and refrigerating circuit pressure After putting into service, do the settings of pressure of the refrigerant circuit for having an optimal operating of the heat pump, following: Stage 1: Before starting the Heat Pump, ambient temperature around 20°C, refrigerant meter shows pressure from 14 to 16kg/cm².
7- Defrosting 1. Defrosting conditions under heating mode: When heating, the cumulative running time of the compressor ≥45min (parameter 11) , and the continuous running time of the compressor ≥5min; Cooling coil temperature <-3°C (parameter 12); (ambient temperature - cooling coil temperature) ≥ 5°C (parameter 15), and -7 °C ①...
8 – Environment problem Under certain external conditions the heat exchanges between the refrigerant and the water on one hand and between the fluid and the air on the other hand are insufficient; the consequence is that the refrigerating circuit runs up in pressure and the compressor consumes more electricity.
Page 21
Connection fault Check the connection Inlet temperature sensor Inlet temperature sensor fault Replace the inlet temperature E 15 fault sensor Evaporator fault Check the connection Evaporator temperature Replace the Evaporator E 16 Evaporator sensor fault sensor fault temperature sensor Connection fault Check the connection Compressor exhaust Compressor exhaust sensor...