Aseptico AEU-10C/SS Operation And Maintenance Instruction Manual

Power-tip systems

Advertisement

Quick Links

Operation and MAINTENANCE
INSTRUCTION MANUAL
AEU-10C/SS Power-Tip Systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEU-10C/SS and is the answer not in the manual?

Questions and answers

Summary of Contents for Aseptico AEU-10C/SS

  • Page 1 OPERATION and MAINTENANCE INSTRUCTION MANUAL AEU-10C/SS Power-Tip Systems...
  • Page 2: Table Of Contents

    Operation ......3 www.aseptico.com • info@aseptico.com Handpiece ......4 Troubleshooting .
  • Page 3: Package Contents

    Your new Aseptico AEU-10 Power-Tip System is one of the finest ongratulations motor/handpiece combinations available to the professional. This system is engineered to provide many years of reliable service. Please read the instructions provided in this manual to receive the best and longest service from your Aseptico equipment.
  • Page 4: Setting Up The Unit

    SETTING UP THE UNIT: Figure 1 1. Plug the AEU-10 console into a ‘ON’ standard 120 Volt AC grounded power Indicator Console outlet. (220 Volt AC unit is also available) 2. Plug the micro motor into the On / Off receptacle on the front of the console Switch labeled 'motor'.
  • Page 5: Operation

    Figure 2 POWER 'ON' HAND/FOOT SPEED SWITCH INDICATOR SELECTOR DIAL MOTOR FWD/REV RECEPTACLE SELECTOR OPERATION: 1. Turn the power switch to the 'ON' NOTE: position. When switched on, the If motor stops due to an open collet L.E.D. 'ON' indicator should light. or excessive pressure: 2.
  • Page 6: Handpiece

    HANDPIECE: The Aseptico AEU-10 System includes the AHP-101 straight handpiece. This handpiece features a quick-twist chuck that will accept any standard HP (3/32") shank bit (or bur) or any Doriot style attachment. To Install Bit: To Remove Bit: 1. Open collet by turning grip 1/4 turn as 1.
  • Page 7: Troubleshooting

    TROUBLESHOOTING: Problem: Correction: “On” Indicator does not light • Check console to power connection. when turned on: • Check that voltage is proper voltage. • Check fuse. If blown, replace with 5x20mm 0.5A/250V fast-acting fuse. “On” Indicator lights when turned •...
  • Page 8: P.o. Box 1548 • Woodinville, Wa

    Aseptico shall be the sole arbiter of such action. In the event of alleged defect under warranty, the purchaser is to notify Aseptico's Customer Service Department promptly. Customer Service will provide instructions, usually directing that the product be returned for service.