AngioScan-01 Diagnostic Device of Cardio-Vascular System State Contents Chapter I Introduction 1 Technical Specifications ........................... 2 Package list ........................... 3 System Requirements ........................... 4 Operating Restrictions ........................... 5 Warranty ........................... 6 Developers Information ........................... 7 Certificate in Regulatory Compliance ...........................
Page 3
одерж ние SIr - Reference Stiffness Index ................................. 43 TdVMax - Time of maximum blood filling rate ................................. 44 2 Occlusion Test ........................... Patient preparation requirements ................................46 Occclusion test procedure ................................46 Occlusion test results ................................47 Occlusion indexes by sensor channel .................................
Page 4
AngioScan-01 Diagnostic Device of Cardio-Vascular System State "Key Mappings" Bookmark ............................100 "Toolbar" Bookmark ............................100 "Misc" Bookmark ............................100 "Tools" Menu ................................101 "Calculator" Dialog ................................. 102 "Test statistics" Dialog ................................. 103 "Import Database Report" Dialog ................................. 103 "Windows" Menu ................................
Introduction Introduction 1. The User Guide (UG) is designed for customers and engineers working with AngioScan-01 Diagnostic Complex of Cardio-Vascular System State (further "AngioScan device" or "AngioScan"). 2. The User Guide contains all necessary information about operation and technical characteristics of the device, about its preparation for work and exploitation rules.
USB port. Warranty "AngioScan-Electronics" Ltd. guarantees an excellent performance of AngioScan-01 device for 24 months since the date of sale to a consumer, if all conditions and rules of exploitation, transportation and storage are observed as specified in instruction manual. During the warranty period, the manufacturer provides free repair of the device in case of any malfunction being the fault of the manufacturer.
AngioScan Software Installation AngioScan Software Installation Several versions of AngioScan software can be installed on one PC. Software updates are available via Internet. When updating the software, the installer checks already installed versions of AngioScan software and proposes to transfer working environment of existing version to the updated one. Working environment contains AngioScan setting files.
AngioScan Software Installation USB Driver Installation The driver will be installed automatically during the AngioScan software installation. In case of error, window of driver's installer will remain on screen. AngioScan device can be connected or disconnected from computer. It is preferable to connect the device to computer after software and driver installation, as in this case "Found New Hardware"...
Quick Start Quick Start · Install the AngioScan software on your computer without connecting the device to the computer. For more details about software installation, see AngioScan Software Installation. · Connect the device to USB-port with a PC cable included in the package. The system will ask you to install the driver for USB-device found.
Page 17
Quick Start it is necessary register them before the test. Add a new patient to Database. Go to "Patients Database" window. To do so, click the header or toolbar button of the main window. "Patients Database" window will activate. Click "New" toolbar button: The dialogue will open, where it is necessary to enter patient's data.
Quick Start Patient's height is indicated in centimeters. After filling the dialogue fields click "OK" button. The dialogue will close, the patient will be registered in the database, and "Measurements" window will activate. Performance of PPG Contour Analysis Performance of Occlusion Test Performance of Pharmacological Test Use of AngioScan with laptop Please note, if...
Quick Start Sensor signal with interference Sensor signal without interference The interference to sensor signal is likely to make the results unreliable, so it is highly recommended to disconnect a laptop/netbook from the mains supply during the test. Please note, that the power supply should be disconnected from the outlet, not from the laptop/netbook.
Page 20
Quick Start If in "Measurements" window the "Contour Analysis" tab is not activated, click it: Put on the sensor of the 1st channel (the one connected to the left device connector) on index finger of the right hand so that the sensor's wire was on top. During the standard test the patient should sit in a relaxed position, the hand with a sensor should be placed on a table.
Quick Start Performance of Occlusion Test Requirements for preparing to the test: 1. The test is to be performed in the morning, on an empty stomach. 2. Tobacco smoking, intake of vaso-active drugs, intake of caffeine, alcohol or other stimulants, moderate and heavy physical activity should be stopped one day before the test.
Page 24
Quick Start In the very top of the window, under the toolbar, there is a status bar where the information about current test phase is given.Approximately 1 minute after the beginning of the test "Occlusion Test can be started" message will appear in the status bar. Then it is necessary to pump air into the cuff until the pressure is 220-240 mmHg and maintain this pressure throughout the occlusion phase.
Quick Start Performance of Pharmacological Test Add a patient to the database, if he has not been not registered yet, or select the registered patient by double clicking his data. Activate "Measurements" window by clicking its header or its button at main window toolbar: If in "Measurements"...
Page 27
Quick Start Wait for a few seconds until the waves become more stable and then click "Record" toolbar button or press F9 key. The data recording will start: Approximately 1 minute after the start of the test the patient can take the medicine which effect is test's subject.
AngioScan Medical Tests AngioScan Medical Tests PPG Contour Analysis 4.1.1 Patient preparation requirements 1. The testing can be conducted at any time. However, when the purpose of the study is to evaluate the effects of a therapy (for instance, therapies for treating hypertension, heart disease, or diabetes), the testing should be done in the morning in order to eliminate the influence of circadian rhythms on test results.
AngioScan Medical Tests 4.1.2 Test procedure for contour analysis The test procedure consists of the following steps: 1. Measure arterial blood pressure with a certified device based on the standard oscillometric method. 2. Open the "Patient Database" tab in "AngioScan" and add a new patient by clicking on "New". Fill in the fields: name, date of birth, gender, height and comments.
AngioScan Medical Tests 4.1.4 Contour analysis test results HR - Heart Rate SI - Stiffness Index SIr - Reference Stiffness Index RI - Reflection Index AIp - Augmentation Index AIp75 - Augmentation Index at HR=75 AGI - Aging Index VA - Vascular Age ED - Ejection Duration PD - Pulse Duration % ED - Ejection Duration Percent...
AngioScan Medical Tests 4.1.4.1 HR - Heart Rate The pulse rate at the fingertip corresponds to the heart rate. The heart rate between 60 to 90 beats per minute is considered normal [Braunwald's Heart Disease, 9th ed, 2012]. When evaluating the results of the heart rate measurements it is important to consider the presence of the diseases that can lead to changes in the heart rate and the therapies that can cause a reduction in the heart rate (for instance, the beta-blockers).
AngioScan Medical Tests wave. As a result, the Type A pulse wave is formed with a pointed apex, corresponding to high pressure augmentation. In this situation, augmentation index has positive value. The higher the stiffness of the arterial wall, the greater the value AIp. In assessing the augmentation index, it is essential not only to look at its absolute value but also the sign of the indicator.
Page 36
AngioScan Medical Tests significant disorders of the cardiovascular system. Type C pulse wave is characterized by the maximum of the reflected wave in the late systolic phase, and its projection to the curve (yellow) is on a downward shoulder close to the time of closure of the aortic valve.
Page 37
AngioScan Medical Tests Type B pulse wave is characterized by the maximum of the reflected wave in the middle of systole, and the point of projection on the curve is almost the same as the global maximum of the pulse wave. This type of pulse waves is often observed in patients older than 40 years.
AngioScan Medical Tests Type A pulse wave is characterized by the global maximum of the pulse wave coinciding with the maximum of the reflected wave. This type of pulse wave is observed in the elderly and in patients with hypertension and other diseases of the cardiovascular system. 4.1.4.5 VA - Vascular Age Vascular age (VA) is a calculated parameter based on age index.
Page 39
AngioScan Medical Tests In this example, stress index and heart rate variability histogram are typical for a healthy person. The heart rate variability is due to the effect of the breathing on the heart rhythm, which adjusts, beat-to-beat, to maintain arterial blood pressure.
AngioScan Medical Tests In the absence of significant diseases of the cardiovascular system, a high index of stress can be observed during a physical or emotional exhaustion. In such cases, a test should be repeated after a sufficient rest period, for example, after a night's sleep. The index values of stress and functional status of compliance: less than Possible arrhythmias or artifacts caused by movement of the patient...
Page 41
AngioScan Medical Tests Stiffness index = L (m) / T (s), where L - length of the aorta (calculated automatically from the patient’s height); T - the time between the maximum amplitudes of the direct and reflected pulse waves. Stiffness index score is based on the determination of the time interval between the early (direct) and late (reflected) systolic waves.
AngioScan Medical Tests 2002, 2003]. Currently, PWV is the "gold standard" of the assessment of vascular wall elasticity [Laurent et al. 2006]. It was shown large prospective studies that an increase in pulse wave velocity is significantly associated with an increased risk of total and cardiovascular mortality in the elderly [Meaume et al. 2001; Sutten, Tyrrell et al.
AngioScan Medical Tests 4.1.4.10 AGI - Aging Index Aging index (AGI) is an indicator of the relative amplitudes of the various components of the pulse wave. One of the research methods used in calculating AGI is a mathematical analysis of the features of the derivatives of the pulse wave.
AngioScan Medical Tests Normal values of the age of the index based on age: Age (years old) Female Male 20 - 30 -0.95+0.31 -0.91+0.23 30 - 40 -0.64+0.26 -0.86+0.28 40 - 50 -0.36+0.23 -0.57+0.28 50 - 60 -0.16+0.27 -0.20+0.30 60 - 70 0.03+0.26 -0.01+0.27 older than 70...
AngioScan Medical Tests and is used as a symptom of adverse changes when ED exhibits atypical values. 4.1.4.12 %ED - Ejection Duration percent The ejection duration percent (%ED) is the duration of the systole expressed as a percentage of the duration of the cardiac cycle This parameter determines the ratio of the duration of the systole and the diastole in the cardiac cycle.
AngioScan Medical Tests 4.1.4.16 dTpp This time parameter is the time between the peaks of the direct (early systolic) and the reflected (late systolic) waves. The longer is this time interval, the more elastic is the aorta. The parameter has a diagnostic value only when its values are either zero or negative (pulse waves of types C and B).
AngioScan Medical Tests 4.1.4.18 SPa - Systolic Pressure, Aortic This parameter corresponds to the level of blood pressure in the proximal aorta and brachiocephalic vessels. Typically, in young people, without cardio-vascular disease, the blood pressure in peripheral arteries (such as brachial artery) is slightly higher than that in the aorta and brachiocephalic arteries. This phenomenon is due to the amplification of the pressure amplitude of the peripheral pulse wave, and helps to maintain a constant blood flow rate to peripheral organs.
AngioScan Medical Tests 4.1.4.22 TdVMax - Time of maximum blood filling rate Occlusion Test An occlusion test is simple and non-invasive. During the test, there is a complete clamping of one of the peripheral arteries for a few minutes. In response to the occlusion, after the clamping has been released, there is a change in the of blood flow distal to the site of compression.
Page 49
AngioScan Medical Tests An example of an occlusion test data in a subject with an impaired endothelial function. Physiological effects of brachial artery occlusion can be described as follows. After releasing the cuff pressure, the blood flow in the brachial artery increases dramatically (by 300 - 800%). An increase in the rate of blood flow in the brachial artery raises the shear stress on the surface of the endothelial cells.
AngioScan Medical Tests increased shear stress leads to the activation of nitric oxide synthesis by endothelial cells. A local increase in the concentration of nitric oxide has an impact on the tone of smooth muscles of the arteries, leading to their dilation. When dilation of the brachial artery occurs, the pulse wave amplitude increases.
AngioScan Medical Tests 3. After adding a new patient profile to the database, open the window "Measurements" and choose the "Occlusion Test" tab. 4. Place the optical sensors at the tips of the patient's index fingers ensuring that the connecting sensor cable is on the same side as the finger nail.
AngioScan Medical Tests 4.2.3.2 Occlusion index by pulse wave amplitude By monitoring the pulse wave amplitude before and after occlusion, the change in the blood volume in the fingertip can be estimated. In order to calculate the occlusion index by pulse wave amplitude, a correction to the change in the amplitude of the reference channel is made.
AngioScan Medical Tests 4.2.3.3 Phase shift The phase shift parameter is computed at the end of an occlusion test and characterizes the vasomotor response in major arteries. It has been shown that the pulse waves velocity decreases after an occlusion in arteries distal to the site of occlusion.
AngioScan Medical Tests Thus, the results of the test occlusion can judge the state of endothelial function in small resistance arteries (occlusion index) and large muscle (phase shift). Pharmacological Test Pharmacological test is designed to monitor and analyze the impact of pharmacological stimuli (this term is used broadly to indicate any stimuli, such as pharmaceuticals, dietary supplements, emotional stimuli, etc.) on the cardiovascular system (CVS).
Page 55
AngioScan Medical Tests monitor the effects of the drug. The initial effect of the drug can be seen at 1.5 - 2 minutes, the maximum effect is observed at 5 minutes. Then, gradually, the effect of the drug diminishes. To study the details of the impact of the drug, a contour analysis is carried out. Contour analysis of the baseline pulse waves indicates that is 32.0%, and AIp75...
AngioScan Medical Tests 4.3.1 Patient preparation requirements 1. The test can be conducted at different times of day. However, when the purpose of the study is to evaluate the effectiveness of a therapy (eg, hypertension, heart disease, diabetes), then the tests should be performed in the morning to eliminate the influence of the circadian rhythms.
AngioScan Medical Tests 6. To start data recording, click "Record". The duration of the data collection in a pharmacological test is not limited and can be defined by the operator performing the test. 7. To end the test, click "Stop". Click "Save" to save the test results in the patient database. 4.3.3 Pharmacological test limitations When conducting a pharmacological test, it is important to visually monitor the pulse waves for the...
Graphic Interface Graphic Interface This section contains description of windows, menu and dialogues of AngioScan program. Languages AngioScan's interface can be either in Russian, or in English. Please see languages settings in "Configure" menu: Expert Mode AngioScan program can operate in Expert and User modes. In User mode some advanced functions settings are unavailable.
Graphic Interface Device status indicator On the left side of AngioScan main window there is a device status indicator showing current state of the device in graphic mode, separately for channels 1 and 2: If you move the cursor to indicator, the tooltip will show the information about current state of the device in text format.
Page 61
Graphic Interface On the top of the window there is a list of patients having records in database. In the bottom there is a list of test results that have been performed for the patient selected in top list: The most frequently used commands can be performed by clicking toolbar buttons. To obtain complete list of commands activate local menu by right-clicking at window (in the bottom part there is a "More..."...
Page 62
Graphic Interface To select a patient for test performance click twice on his row or push the button "Select". Name of the selected patient will be displayed in the header of AngioScan main window as well as on toolbar of "Measurements"...
Graphic Interface drop them into top part of the window, to the row of an appropriate patient. 5.1.1.1 Edit New Patient Data To add a new patient, click "New" on Database dialog toolbar: Enter patient's data in the open dialog. Fields in bold must to be filled in (except "Patient ID" field) The patient's height is indicated in centimeters.
Graphic Interface 5.1.1.2 Sorting patients list By default, the list of patients is sorted by patient's name. To select a different sorting criteria, click the appropriate title bar. Then a triangle will appear in the corresponding field: By clicking once again on the same title bar the sorting order will be reversed. Please note, that list sorting is not available for all fields.
Page 65
Graphic Interface History of patients selection AngioScan "remembers" the sequence of patients selected for test. To receive the list click the arrow next to the quick search field: To select a patient, click the line with his name in the list. The patients are sorted according to the sequence they were chosen for test.
Graphic Interface 5.1.1.4 Search Database This function is intended for an extended search of patient(s) in the database. To start search, click the "Search" button on the window toolbar: There is a dialog that allows to set up search settings and results display. ·...
Graphic Interface "Select all found" button performs the search and marks all lines containing fields meeting search conditions: Then it is possible to perform group operations with all marked records. For example, one can delete or save as a table in HTML-file. 5.1.1.5 Delete Patients To remove the patient, choose his record by clicking it and then "Delete"...
Graphic Interface You will be asked to confirm the removal. You can delete several records simultaneously if you mark them as it is described in "Marking several records for group operations". The removal operation is not available when records filter is switched on.
Graphic Interface It is also possible to mark entries with the cursor by holding Shift key. To mark all records use Ctrl+A keys combination. 5.1.1.8 Patients Database Window Setup With the help of "Settings" toolbar button one can specify fields and their order to be displayed in the window: Then "Patient Database Window Setup"...
Graphic Interface Fields flagged with check mark are displayed in the window. It is possible to manage fields order in the window by clicking "Move Up" and "Move Down" buttons: the higher the field in the list is, the closer to the left side of the window it will be.
Graphic Interface There is a description on how to mark entries in "Mark Several Records for Group Operations" menu. The dialog will open where you are asked to name the saved HTML file. When the saving process is completed a default WEB-browser will automatically open. An example of the table in HTML file: 5.1.1.10 Database Filter Setup Records Filter is an advanced option allowing to display only those entries that match with specified criteria.
Page 72
Graphic Interface Switch on the filter. "Insert Condition" button will become available as well as other buttons to the left from "Filtration Condition" field, where specified conditions will be displayed. "Insert Condition" button opens the dialog, where you can set a filtering condition: On the top side of the window you can set a field of database records according to which the filtration will be performed.
Page 73
Graphic Interface Then specify the condition of filtration. The list of conditions depends on field type: for number fields it will be as it is shown in the picture below, for text fields one can specify criteria of matching with substring and for date field - to choose a date.
Graphic Interface If you add one more condition in a similar way, the list of conditions will be like this: Two entered conditions will be connected with each other by "AND", i. e. the records matching with both conditions will appear in the window. To change "AND" to "OR" click a row with "AND" in the list on the left, then click the button "AND"...
Graphic Interface "Open Histograms" window looks like: The horizontal axis in this picture is height (in centimeters) and the vertical one shows the number of patients of a corresponding height.For example, it is well seen in the picture that there is one registered patient with a height of 150 centimeters and 9 patients with the height of 178 centimeters.
Graphic Interface Test Data will be downloaded from the database, "Measurements" window will activate and switch to the tab appropriate to the type of downloaded test. Graphs and results will be displayed in the form they were after test performance, for example: 5.1.1.13 Export Scan Data This command allows to export scan data in form of text file for further analysis in PowerGraph program, as well as to export data of one or several tests to another AngioScan database, for example, for...
Graphic Interface To database... This option allows to export data of one or several tests to another AngioScan database for transferring it to another computer. It is possible to export several records if you mark them as it is described in "Mark Several Records for Group Operations"...
Graphic Interface The graphs of all PPG contour analysis tests are displayed for one patient by default. It is possible to view only several test records if you select them in the window as it is described in Mark Several Records for Group Operations": Note that it is possible to enlarge the size of the window (as well as the size of other AngioScan...
Graphic Interface Note that it is possible to enlarge the size of the window (as well as the size of other AngioScan dialogues) if you pull its lower right corner. There are graphs in the bottom part of the window, list of tests (according to which the graphs are made) sorted by date on the top, test results selected in the list on the right side of the window.
Graphic Interface only those records that another patient (receiver) does not have. 5.1.2 "Measurements" Window This window has an interface for medical tests performance, as well as for display and analysis of test results. It has three tabs with corresponding test types: PPG Contour Analysis, Occlusion Test, Pharmacological Test To switch quickly to "Measurements"...
Page 81
Graphic Interface General Information about Test Performance In "Measurements" window click the tab corresponding to the type of test performed. Put the 1st channel sensor (it is switched to the left connector of the device) on patient's finger. When performing the Occlusion test, put the 2nd channel sensor to another hand's finger of the patient.
Graphic Interface To start recording data, click "Record" or push F9 key. The specific features of performing the particular types of tests are described in the relevant sections of this chapter. "Calibration" button performs compulsory calibration of signal frequency. It is useful when there is no device's signal due to high transparency of the object device is put on.
Page 83
Graphic Interface 30 pulse waves (of which 20 waves remain after processing) are sufficient for estimation of contour analysis parameters. Other waves with extreme values of parameters are rejected (in expert mode number of waves as well as other test settings can be changed in Advanced AngioScan Settings).
Page 84
Graphic Interface To escape from time interval measure mode left click the mouse. To measure the blood pressure interval, perform the same actions holding Ctrl key. There are elements controlling graphs view and lists of measured parameters of contour analysis to the right of the graphs.
Page 85
Graphic Interface database. These buttons are available if the results of test downloaded from database are displayed in the window. Stress Index Histogram The height of each histogram column shows a number of heart beats of certain duration corresponding to the column's location on horizontal axis.
Page 87
Graphic Interface The upper graph corresponds to the 1st channel, and the lower one indicates the 2nd channel. The Occlusion test is performed on the hand the 1st channel's sensor is put on. The picture above clearly shows how the signal amplitude decreases during the occlusion test. The horizontal axis chows time in minutes.
Page 88
Graphic Interface It is possible to display graphs of PPG contour analysis parameters for the 1st channel, that has performed the occlusion test. In this case, enable the option "Graphs of Contour Analysis Parameters for the 1st Channel" in Occlusion Test Settings.
Page 89
Graphic Interface Phase shift is the difference between the time of receiving pulse wave by channel 1 and channel 2. The Occlusion Test indexes are described in "Measured Parameters of Occlusion Test" section. Estimation of the average values of Contour Analysis parameters in intervals As a result of test, two lists of Contour Analysis parameters for each channel are created.
Page 90
Graphic Interface Show Absolute Values Show Differences The upper list displays the values of the 1st channel and the lower one shows the values of the second channel. When moving the assessment intervals on chart with the help of the mouse, the automatic recalculation of measured parameter values is performed.
Graphic Interface "Recalculate" button at "Test Results" tab. PPG Contour Analysis from the specified point In the local window menu (activated by mouse right click) there is a "Contour Analysis from this point" command, that performs the PPG Contour Analysis test from the moment of time corresponding to the position of mouse cursor in the window: The same can be done by double-clicking the selected point.
Page 92
Graphic Interface The measured parameters of the test are described in "Measured Parameters of Pharmacological Test" section. General rules of test performance are described in "Measurements" Window. Please note, that unlike PPG Contour Analysis or Occlusion Test, Pharmacological test do not finish automatically, because the termination of the test is to be determined by the doctor.
Page 93
Graphic Interface average values of parameters tested an interval before taking the medicine (the blue area on the graph), the second list shows the average values taken an interval after taking the medicine (the pink area on the graph). On the right side of the tab there are the values of parameters displayed either in In the right part of the tab there are parameter values displayed either as absolute values or as values differences: Show Absolute...
Page 94
Graphic Interface PPG Contour Analysis from the specified point In the local window menu (activated by mouse right click) there is a "Contour Analysis from this point" command, that performs the PPG Contour Analysis test from the moment of time corresponding to the position of mouse cursor in the window.
Graphic Interface 5.1.3 "Console" Window "Messages Console" window displays the AngioScan program messages that appear during the test. Error warnings are coloured in red, and the information messages are black. "Messages Console" window stores the last 1024 messages even when it is closed. It is possible to open it and view the messages at any time as well as to receive help on each message.
Graphic Interface 5.2.1.1 Configuration Files When finishing the session, AngioScan automatically saves the configuration parameters in several files. When the new session begins, these files will open. Via Configuration File command in File menu, it is possible to save and download any file separately at any time as well. It is also possible to create several sets of configuration files with different settings of AngioScan, and load them when it is needed.
Page 98
Graphic Interface Dialog Item Description It is possible to select LEDs for different tests. Each sensor has a red and Contour Analysis LED infrared LEDs. Mode Allows to save uncompleted scan data in the database. It can be useful, for Allow saving of example, for analysis of various noises effects on device when pulse waves are incomplete scans...
Graphic Interface 5.2.3.1.2 "Stand-alone device" Bookmark This dialog allows to set the configuration of stand-alone (with display) one channel AngioScan-01P personal device. The tab of the dialog s available if the device is connected to the computer. Dialog Item Description Choose the patient for the test in stand-alone mode in this drop-down list.
Graphic Interface Controls the device display contrast. Display Contrast Synchronizes the device's time according to computer's one each time you Synchronize device's connect the device to computer. Synchronization is performed when time to computer's AngioScan program activates. time when connecting device to computer Switches on the device sound.
Page 101
Graphic Interface Dialog item Description Oscilloscope Advanced settings of tables and filters that are used for sensor signal smoothing filter processing. For every table and filter there is a "default.xxx" item, that is set by default. Smoothing filter Derive table Occlusion test filter Wave input filter Pharmacological test...
Graphic Interface settings. To cancel the password, set an "empty" one. Keep common In drop-down list, select the number of days of the common database database backup backup copies storage. Backup copy is created every day when AngioScan copies for the last ... program activates.
Graphic Interface Additional line spacing Sets line spacing that will be added to the standard line spacing. The new value can be printed or chosen from a list of recently used values. Define font... Opens Font dialog.The selected font will be applied for all windows of this type.
Graphic Interface 5.2.3.2.3 "Key Mappings" Bookmark "Key Mapping" tab of "Environment" dialog allows to assign any AngioScan command to key combinations, including local menus activation. "Menu commands tree" column displays tree structure of commands. Columns Key 1 (Key 2) contain the appropriate keys combinations assigned to commands. All actions in this tab apply to the marked command.
Graphic Interface Line program. Highlight active tabs Turns backlight of the current tab (in MS Windows) in windows with tabs. Double click on Sets the mouse double click function, that is equivalent to a single click on a checkbox or corresponding dialog item and clicking OK button of the dialog.
Graphic Interface you to copy the database without knowing the location of the file at computer. Only folder name or device name are required. Test statistics... Displays the performed tests statistics dialog at certain time intervals. The statistics are shown on base of information of currently open database. Edit clinic/working This command is used for connection with a remote database and allows to place information...
Graphic Interface -126 (2 + 2 * 2) - 33h (float)(33000 / 4) 5.2.4.2 "Test statistics" Dialog This dialog displays information on the number of tests performed in various time intervals. It is also possible to set the length of the interval explicitly, by specifying the start and end date. The "Interval Report"...
Opens "Contents" tab of Help Menu. Search for help on Opens "Index" tab of Help Menu. Visit AngioScan Runs WEB-browser and goes to AngioScan Electronics WEB page. Electronics Web site Check for updates... Verifies whether new version of AngioScan is available. This function is enabled only when computer is connected to the Internet.
Appendix Appendix Information about AngioScan Database AngioScan Database file is named Patients.sq3. The database with several patients' demonstration records is included in Packing List. After installing AngioScan program to computer the database file is copied to the following directory: Under Windows XP: C:\Documents and Settings\<user name>\My Documents\AngioScan Under Windows Vista, Windows 7 and later versions of Windows OS: C:\Users\<user name>\Documents\AngioScan...
Appendix When starting AngioScan one can specify name of database file that should be used in AngioScan.exe command line. To specify common database one can use alias $common. When you run <% CM%> in the command line <% CM%>. Exe you can specify the file name of the database to use.
Page 112
Appendix 6.2.6 13012 No field matching the criteria is found in the database. 6.2.7 13015 Filter condition contains a bracket without a corresponding pair. 6.2.8 13017 No record matching the filter conditions is found in the database. 6.2.9 13025 The test has been interrupted before AngioScan accumulated enough data for obtaining reliable results. The occlusion and pharmacological test indexes will not be calculated.
Page 113
Appendix cables. If electromagnetic or optical interferences occur, the graphs will look like it is shown in the following picture: 6.2.14 13072 There are no saved test results of this type for the patient selected. 6.2.15 13074 Occlusion test has been interrupted before its completion. If you click "No", the test will be continued. 6.2.16 13083 At least two points are necessary for making trends graphs, i.
Page 114
Appendix To save rest results in the database, click "Save" toolbar button of Measurements Window. 6.2.22 13104 Each line of the importing text file must have the following format: 0:00:32.987 58004 41517 The first column is time (h: mm: ss: ms), the second one is the value of channel 1 signal, and the third one is the value of channel 2 signal, if it is used in test (Occlusion test).
Appendix 6.2.28 13113 Device sensor signal level is too high. The possible reason of too high signal level is incorrectly put device sensor. Check the sensor and repeat the test. 6.2.29 13114 The signal level of two sensors is too low. The possible reason of too low signal level is incorrectly put device sensors or opaque nail polish.
Appendix During the quick registration, AngioScan itself creates user names (User1, User2, ...). The device's serial number is used as user name. Further, if you want to change user data, go to "Settings" -> "AngioScan Settings" -> "Stand-alone device" tab, as well as to patients database dialogue. 6.2.37 "New test data found in memory"...
Page 117
Appendix When connecting the stand-alone device AngioScan-01P to computer, AngioScan program analyses the data stored in memory of stand-alone device. If there are records of users not registered in computer's database, AngioScan offers to enter data for each user: first name, second name, date of birth, etc. After the user data is entered, it will be stored in computer's database and updated in stand-alone device memory.
AngioScan-01 Diagnostic Device of Cardio-Vascular System State AngioScan updates Index AngioScan webpage AngioScan windows Anvanced mode "Advanced" Tab (AngioScan settings) Blood oxygen saturation "AngioScan setup..." Dialog, AngioScan" "Calculator" Dialog "Check for updates..." dialog "Colors" Tab, ("Environment" dialog) "Configure" Menu Calculator, dialog "Edit New Patient Data", dialog...
Page 119
Index Help, menu Search Database Histograms Simulate Scan Histograms window Sorting the list of patients History of patients selection SpO2 HTML file fo save records Thumnails of PPG Contour Analysis Results Infrared LED Toolbar, tab of "Environment" dialog Tools, menu Transferring Scan Data Between the Patients Trend Graphs Key Mappings, tab of "Environment"...