8к21 sb control unit rolling shutters&awnings 230v (20 pages)
Summary of Contents for Zero COMANDO 24
Page 1
ZCOMV2 |CONTROL PANEL | COMANDO 24V COMANDO 24 CONTROL UNIT SLIDING GATES AND GARAGE DOORS IT | EN | FR ZCOM24 VER1.0 01012018_REV1 USER MANUAL AND CONFIGURATION made in italy...
Page 3
09 • Pedestrian START input (NA) •ZERO SRL is not responsible for the improper use of the pro- 10 • Open/close input (NA) duct, or other use than that for which it was designed.
ZCOMV24 |CONTROL PANEL | COMANDO 24V PROGRAMMING PRE-RECOMENDATIONS 04 • When the gate arrives at the closed position, press the SW1 PROGRAM button located on the control board for 2 se- Before proceeding to the control board configuration, note the conds until the CODE LED (see connection diagram page) stays following points listed in the table below in order to better un- illuminated.
Page 5
ZCOMV2 |CONTROL PANEL | COMANDO 24V DIP 1 - ON and DIP 2 - OFF DIP 7 - ON Condominium function with automatic closing: Enables automatic closing 3 seconds after photocells are in- Transmitters aren’t accepted during opening and during clo- terrupted sing it reverses direction and stops only at the gate’s end.
Page 6
ZCOMV24 |CONTROL PANEL | COMANDO 24V FORCE AND SENSITIVITY REGULATION (ANTI-CRUSHING) The control board has 1 trimmer : TR11 - Allows the automation sensitivity regulation (increases sensitivity by rotating it in the clockwise direction); If activated between the LIMIT SWITCH positions the motion of the gate is reversed for 2 seconds to free the obstacle im- pact (moving the trimmer clockwise increases the current force necessary to stop the gate motion).
ZCOMV24 |CONTROL PANEL | COMANDO 24V LED DESCRIPTIONS COLOR FUNCTION DESCRIPTION Comes on when the PEDESTRIAN start command is activated and goes off when released. Comes on when the START command is activated and goes off when released. Always on. Goes off when the photocell is intercepted interrupting the PHOTO beam. Comes on when SAFETY EDGE is activated and while programming.
Page 11
ZCOMV2 |CONTROL PANEL | COMANDO 24V FLASHING LIGHT CONNECTIONS LED LAMP BULB LAMP LIMIT SWITCH (GATE OPEN/CLOSE POSITION) CONNECTION NOTE: ON-BOARD MAGNETIC LIMIT SWITCH FUNCTION the control unit is equipped with a CN2 connector to accommodate a magnetic limit switch module directly welded on control panel (on demand and just for Z01 model, will be also provided two magnetic stoppers for end limit switch positions).
Procedure Behavior Procedure II Make sure you have 24V Door doesn’t work power supply connected to Consult a qualified ZERO tech- Still not working. control board and if it is wor- nician. king properly. Consult an experienced gate Encountered problems? expert.
Page 13
All ZERO control boards have LEDs that indicate the functioning of connections to allow easy diagnosis of faults. All safety devices LEDs (DS) in normal situations remain On. All “START” circuits LEDs in normal situations remain Off.
Page 14
ZCOMV24 |CONTROL PANEL | COMANDO 24V EC DECLARATION OF COMFORMITY: The undersigned Mr. ANDREA MARAN , representing the following manufacturer, ZERO SRL Via Roma 25/A 36077 ALTAVILLA VICENTINA (ITALIA) Declares that the equipment described below: Description: Electronic control unit Model:...
Need help?
Do you have a question about the COMANDO 24 and is the answer not in the manual?
Questions and answers