Baer M-Bus AMR Interface E350 User Manual

Advertisement

Quick Links

Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950
General
Upgradable for future communication needs: flexible remote communication modules without breaking
approval seal. The new series of modules for domestic use puts promises into practice, paving the way not
only for multi-energy applications but also for new services in personal energy management.
This specification details the operation and the electrical requirements for connection of an AMR module
with M-Bus interface to the L+G E350 (ZxF series 100) meter.
Functions
The AMR interface contains the following functions:
Bi-directional communications: an integrated M-Bus (2 wires, passive) interface provides a simple
means of connecting multi-energy meters. This makes multi-energy applications an affordable
proposition for domestic use. Transmission protocol: IEC 62056-21
Rate input for tariff switching via external control inputs
Pulse output (with pulse rate change)
Internal communication interface for the transfer billing data between the meter and AMR module
(every 10 seconds).
For details of the communications protocol, refer to the software interface specification (IEC
62056-21 and OBIS Codes).
Phase connections to one phase (230VAC)
Safety Notes
The owner of the AMR modules is responsible that all persons engaged on work
with the modules:
• Are competent and qualified in accordance with national regulations (see ISSA
"Guideline for Assessing the Competence of Electrically Skilled Persons").
• Have read and understood the relevant sections of the user manual.
• Strictly observe the safety regulations (according to the following section) and
the instructions in the individual chapters.
The owner of the modules is also responsible for:
The protection of persons.
The prevention of material damage.
The training of personnel.
The following safety regulations must be observed at all times:
Devices which have fallen down should not be installed, even if no damage is apparent, and should
be returned for testing to an authorised service centre (internal damage possible).
Modules must never be cleaned with running water or high pressure devices. Water can cause
short-circuits or damage el. components.
M-Bus AMR Interface E350
User Manual
Compatible meters
ZCF110/120 single phase meter
ZMF110/120 multiphase meter
ZFF110/120 multiphase meter
Page 1 from 6
E111306819090

Advertisement

loading

Summary of Contents for Baer M-Bus AMR Interface E350

  • Page 1 Page 1 from 6 E111306819090 User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 General Upgradable for future communication needs: flexible remote communication modules without breaking approval seal.
  • Page 2 E111306819090 User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Installation Hints The installation must be done in a way, that even in the case of cable break no dangerous voltages are applied to touchable parts of the module.
  • Page 3 Page 3 from 6 E111306819090 User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Rate Input The module provides a single optically isolated rate input. Maximum voltage: 230VAC (-20% / +15%) / 2mA Function: no voltage on the rate input: T1 (register 1.8.1 active), default...
  • Page 4 E111306819090 User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Jumper 3 and/or 4 is used for setting the pulse rate for the pulse output: 1/1:...
  • Page 5 Page 5 from 6 E111306819090 User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Technical data: Housing: Polycarbonate housing with terminals for using with Landis+Gyr E350...
  • Page 6 M-Bus AMR Interface E350 Page 6 from 6 E111306819090 User Manual Baer Energie- & Messtechnik GmbH  Siemensstr. 3  D-90766 Fürth  Phone +49 911 970590  Fax +49 911 9705950 Terminal assignment Power connection via connection spring: Connector...