This product contains some codes from GPL. In compliance with GPL agreement, AirLive will publish the GPL codes on our website. Please go to www.airlive.com and go to the "Support->GPL" menu to download source code. All Trademarks are properties of their respective holders. AirLive SI-108 User Manual...
Page 3
To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. AirLive SI-108 User Manual...
Enabled Z-Wave Plus Controller must be used in order to fully utilize the product. The SI-108 is a Z-Wave slave device; it depends on the gateway on how to setup a particular AC brand with the correct IR code. Different gateway’s have different user interfaces for setup.
Association Group #1 Association Association Group #1 (max. 1 node) is default to associate with the primary controller (Gateway/Hub/Controller) for SI-108 Status change report, refer to below for report details: • Current Room Temperature (report in precision of 0.5°C or...
Do not locate the SI-108 IR Controller facing direct sunlight, humid or dusty place. The suitable ambient temperature for the SI-108 IR Controller is 0°C~40°C. After putting it into use, the body of SI-108 IR Controller will become a little bit hot of which phenomenon is normal.
• Open the SI-108 Casing • Install CR123 batteries (when not included) • SI-108 will detect the first applied power source to decide what Z-Wave device role it will be in after included into the Z-Wave gateway: battery= sleeping device (FLiRS mode).
UI for the IR code setup please refer to the gateway UI and ignore the below steps. • If your gateway does not have dedicated UI for SI-108 code setup, but support Z-Wave thermostat Command Class and Configuration Command Class. You may refer to below steps to setup the IR code using the configuration options in your gateway.
Page 10
• Keep away from Incandescent Light or Direct Sunlight during learning. • Make sure IR Transmitter of your Original Remote alight with learning diode of SI-108, you may also slight adjust closer or further away the distance between the two devices. For some Remotes the IR transmitter is hidden behind a lens and may not be installed at the center of the remote.
Page 11
74°F or 75°F HEAT 24°C HEAT 76°F HEAT 25°C HEAT 77°F or 78°F HEAT 26°C HEAT 79°F or 80°F HEAT 27°C HEAT 81°F or 82°F HEAT 28°C HEAT 83°F or 84°F HEAT 29°C HEAT 85°F HEAT AirLive SI-108 User Manual...
Page 12
Data to Air Conditioner if User set 27°C Cool on the gateway. • User can still use gateway to set up Scene and Schedule with SI-108. For example, to have AC turn on at 23°C every day at 7am or 25°C at 11pm. Just make sure the set code is learnt.
Page 13
Range: 0 to 4 (0x00 to 0x04) 0(0x00) : Idle - IR Channel is idle 1(0x01) : OK - the last learning Operation was completed successfully Check IR 2(0x02) : Learning - SI-108 is busy Code Learning 26(0x1A) processing previous learning request...
Page 14
1.5.3. Firmware update Over The Air (OTA) The SI-108 is based on 500 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z-wave RF media. It is a helpful and convenient way to improve some function if needed.
Notes: Reset to Factory Default Press and Hold “add” button for 10 seconds on SI-108, the Green Indicator will light up. Then Release the “add” Button until Green Indicator flashes TWICE. Z-WaveTM Notification After the device adding to the network, it will wake-up one time every 8 hours in default.