ANUAL ACS-50 CONTROL PANEL ASSA ABLOY ENTRANCE SYSTEMS 975-A Old Norcross Road Lawrenceville, Ga 30046 800-252-2691 Tel 770-338-5034 Fax www.albanydoors.com 6410T0008_REV_G...
Incoming Power .................................... 9 Voltage Selector Jumper (J2) ................................ 9 Wiring of the Motherboard ................................9 ACS-50 SETTINGS AND ELECTRICAL STARTUP ........................11 CPU Card Switch Settings ..........................11 (SW2) Rotary Selector Switch for Closing Time ........................11 Table 2 – Sw2 Settings ........................... 11 Setting of Opening and Closing Functions ....................
NEMA 1, 3R, 4, 12 AND 13 ENCLOSURE PROTECTION CLASS: NOTE: 4X STAINLESS OPTIONAL DIMENSIONS: 11.8“W X 15.75“H X 8.25“ DEEP WEIGHT: 24 LBS ALBANY DOOR SYSTEMS RAPID ROLL DRIVE UNITS 1-speed brake motor 2-speed brake motor Unit Output power 1.5/1...
ACS-50 ELECTRICAL PRACTICES WARNING THE ACS-50 CONTROL BOX CONTAINS HIGH VOLTAGE. QUALIFIED ELECTRICAL PERSONNEL SHOULD PERFORM THE FOLLOWING PROCEDURES ONLY. WIRING AND CONTROL PANEL MOUNTING (ANCHORING) MUST MEET ALL LOCAL, STATE, FEDERAL, INTERNATIONAL, OR OTHER GOVERNMENT AGENCY CODES. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH.
ACS-50 Motherboard Layout The following refers to the layout of the motherboard inside the ACS 50 control box: Control Fuses, FU1 – FU6 CPU Card Slot Motherboard Voltage Selector Jumper, Cycle Counter Contactor ”KM1” and ”KM2” Brake Rectifier (230VAC) Contactor ”KM3”...
Page 7
Figure 7 – Single Speed Motherboard Part # 6410T0008 Rev.F...
Page 8
Figure 8 – Two Speed Motherboard Part # 6410T0008 Rev.F...
WIRING TO PANEL Incoming Power Three Phase power coming from a FUSED DISCONNECT is wired into T1, T2, and T3. Located on the disconnect. Voltage Selector Jumper (J2) Check J2 for the proper incoming voltage level. This jumper wire comes from the motherboard and is terminated on a terminal below the control transformer.
Page 10
Table 1 - Mother Board Terminal Wiring Notice Description Terminal T3, N, N NOT USED Mains output (NOT USED) U,V,W Motor (Single Speed) (Din rail mounted on Version 2 board) U2,V2,W2 Motor (Two Speed) (Din rail mounted on Version 2 board) 1 &...
ACS-50 SETTINGS AND ELECTRICAL STARTUP CPU Card Switch Settings (SW2) Rotary Selector Switch for Closing Time Automatic closing can be set from 1-60 seconds. The potentiometer (SW2) is located on the CPU-card; see Figure 12 and Table 2 for settings.
Setting of Opening and Closing Functions In the table below, SW1.1 means switch position 1 on SW1 dipswitch. Likewise, SW1.2 means switch position 2 on SW1 dipswitch. Refer to Figure 12 for switch location. The greyed out section below shows the factory settings. You need to change these settings for your particular needs. Table 3–...
Table 4 – Led Indication of the CPU Card Status Status Status Wiring Terminals / Notes Function COLOR Open (MID) Closed 3(A) & 4(A) Yellow Signal Open 5(A) & 6(A) 1 & 2 or 1A & 2A Signal Stop / Green (Jump if not used) Inertia Brake if Applicable...
Electrical Start Up WARNING First you must determine what type of limit box you have. Consult Figures below to determine this. Figure 14 is the STROMAG limits box. Figure 15 is the TEMEC limit box. Figure 16 is the GFA limit Box.
Limit Switch Coarse Adjustment Refer to the Electrical drawing WD501-0V000 for wiring of the Temec/Ovitor limit switch. For the wiring of the Stromag Limits refer to Electrical drawing WD501-BF000. For GFA LIMIT Boxes refer to electrical drawing WD501-GF02. Warning Rotation of the open limit cam in the wrong direction or incorrect phasing may cause the bottom beam assembly to jam into the top roll.
1. Be prepared to press the STOP button. (Stop on the front panel is a momentary stop only! Door can be activated by motion detector, floor loop, or any activation device) It is highly recommended that ALL automatic or remote activations be disconnected during the startup of the door.
Once the door has been impacted, to restore full function of the door, press the ▲ up arrow button. The door then will go to full open and reset itself close. Runtime Monitoring The controller has an internal timer to measure the door run time when opening or closing. The timer expires after the door runs continuously for 20 seconds (some doors have a 40 second EPROM).
Pressure Switch Adjustment (if Equipped) Bump the rubber safety edge with your hand observe LED 6 (see Figure 9 for location), it should flash on briefly. If the LED does not flash, adjust the switch. The pressure switch is located on the bottom beam see Figure 19. Remove the cover of the pressure switch enclosure.
TROUBLESHOOTING TABLE 5- Controller Faults Red Lamp Alarm + LED 20 (OUTPUT Error Description Indication (ON PANEL STOP TERMS 82-84) BUTTON) Flash Power on test First 3 seconds after Power on Manual lever, Flash LED 9 = OFF Handcrank, activated Safety edge error LED 6 = ON Photocell error...
Page 20
ULTRA ACS-50 FUSING SIZE CHART-(GFA MOTOR) VOLTAGE MOTOR TYPE MOTOR HP MOTOR FLA PANEL FLA PANEL MAIN FUSE 208V 3-Phase 1-SPEED 10.6 13.0 208V 3-Phase 208V 208V 3-Phase 2-SPEED 10.6 13.0 208V 3-Phase 230V 3-Phase 230V 1-SPEED 10.7 230V 3-Phase...
CONTROL PANEL REPLACEMENT PARTS PART # PART DESCRIPTION 4903T0001 Control Panel, ACS50, 220/480/600v, 1-Speed CUL 4903T0002 Control Panel, ACS50, 220/480/600V, 2-Speed CUL 4903T0003 Control Panel, ACS50, Stainless Steel 220/480/600V, 1-Speed 4903T0004 Control Panel, ACS50, Stainless Steel 220/480/600V, 2-Speed 4906T0016 ACS50 Steel Enclosure With Prepunched Holes 4908T0011 Fuse Holder, ACS50 4909T0001...