The absorption and pumping of air or CO2 in gas form as well as cavitation must be avoided. Cavitation and/or compression of gases lead to uncontrollable pressure-kicks which can ruin the pump and pump unit parts and also be dangerous for the operator or anyone standing nearby. CLP124 Lubrication Information/ Torque Specification/Tool List Item #...
Specifications Model CLP124 U.S ......Metric Volume ..............13.5 GPM ....51 LPM Maximum Discharge Pressure .........4350 PSI ....300 BAR Maximum Inlet Pressure ..........4350 PSI ....300 BAR Maximum Power Consumption .........40 BHP ......30 kW Minimum Power Consumption ........4 BHP .......3 kW Maximum Speed ..................
Page 5
CLP124 SPARE PARTS LIST - FLUID END ITEM PART DESCRIPTION ITEM PART DESCRIPTION CP04807 Crankcase CP13243 Fitting Key CP04808 Fixing Screw CP04810 Connecting Rod Assembly CP13000 Oil filler Plug Assembly CP04815 Crosshead w/Plunger CP07102 O-Ring CP04816 Crosshead Sleeve CP04802 Metal Cover...
Repair Instructions To Change Valves Remove nuts (49A). Take off the valve casing (43) or push the drive end back. Screw off nut (46L). Remove disc (46N), guard ring (46M). Using a plastic hammer, disassemble valve (46) by tapping the valve retainer pin (46O) on the front.
RANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER. Sold Exclusively through ECO Blast 1025 W. Commerce Dr., Decatur, IN 46733 Phone: (260)728-4433 www.eco2blast.com Copyright 2018 ECO Blast 08/18 CLP124.indd...