Pason WITS User Guide Revision 25 of DOCU225 Revised May 1, 2019 Quick Links Overview Understanding Pason WITS Connecting Hardware for WITS Communication Setting Up WITS in the EDR Using the WITS Monitor About WITS Port Pin-Outs...
Pason Systems Corp. No part of this document may be reproduced by any means, nor transmitted, nor translated, nor translated into computer language, in whole or in part, without written permission from Pason Systems Corp.
Page 3
Establishing and Maintaining WITS Communication ..........14 4.3 Setting up the EDR Comm Port ..............15 Setting up an EDR Comm Port for WITS Connections via a DHC, Workstation, SideKick, or UJB.....................15 Setting up the EDR Comm Port for WITS Connections via Toolpush Connection Box or Network Panel .....................15...
Page 4
Setting up Custom WITS Codes ................24 Selecting Custom WITS Codes to Send ..............27 Receiving a Custom WITS Code and Sending it as a Different Custom Code ..27 4.7 Setting Up WITS Codes for Custom Sensors ..........29 4.8 Sending WITS 01 Codes to the EDR ............30 4.9 Sending Gamma and Gamma Lag Calc ............
Page 5
Figure 4: COMM022 comm box and components ..................11 Figure 5: COMM087 comm box and components ..................12 Figure 6: Connecting a WITS device to a DHC, SideKick, or UJB ............. 13 Figure 7: Recommended WITS handshaking packet ................. 15 Figure 8: Comm port with a WITS connection ....................
The Pason system uses WITS Level 0 for serial communications. In Send and Receive mode, the EDR transmits a number of WITS Level 0 packets (1 packet in Half WITS mode, approximately 8 packets in Full WITS mode) each time it receives a valid WITS Level 0 packet.
Page 8
The EDR uses this header to distinguish between sent data and received data. If a WITS device requires the removal of the 1984PASON/EDR header, ensure that the device is connected to the EDR via a COMM022, and that its EDR comm port is set to Send Only.
Specifically, note that the RS-232 ports on trailer access points (TAPs) do not support WITS connections. WITS connections to TAPs haven’t been fully tested and their reliability is unknown. Connecting a WITS device to a DHC or SideKick can in some cases adversely affect wireless communications between the DHC and the network.
EDR via a Pason DHC, SideKick, or UJB: 1. Ensure that the DHC, SideKick, or UJB is powered on. 2. Secure the WITS to RS232, 6 ft. cable (CBLASS390) to the WITS Device port on the Hazardous Area WITS Interface Assembly (COMM087). Secure the female DB-9 end to the WITS device.
If connecting to a SideKick, ensure that the port you’re using is set to Auto (Port Info > Port Setup from the SideKick’s main screen). If connecting to a UJB, ensure the port is set to WITS (Setup Ports > Change to WITS from the UJB local interface). This requires UJB firware version 11 or higher.
Set up on UJB If connecting to a UJB, ensure the port is set to WITS. This requires UJB firmware version 11 or higher. Select Setup Ports > Change to WITS from the UJB local interface. Then select either WITS 9600 or WITS 19200.
EDR Comm Port list. In these cases, you do not need to set up a comm port. To determine if WITS is working in these setups, check the WITS monitor, check the EDR for WITS traces sent by the third-party device, or check the third-party device for WITS values sent by the EDR.
The EDR uses several comm ports for communicating, so you need to determine which port the EDR uses for WITS. Follow the steps below to find the assigned port if you connected the WITS device to the TPC via a COMM022: 1.
Send/Receive Options for WITS Connections via Toolpush Connection Box or Network Panel If you connected the WITS device to one of these panels with a COMM022, you can set the EDR to send WITS data, to receive WITS data, or to send and receive WITS data.
The Comm Port Setup screen opens. Figure 9: Comm Port Setup screen 2. Select the assigned WITS comm port as described in Determining the Assigned Comm Port on page 16. 3. Click either Toggle Next or Toggle Prev to turn off the Auto setting and toggle through the additional protocols.
WITS codes in Default Pason WITS Codes on page 32). If you need the EDR to receive a code not listed in the table, you need to set up a custom WITS code as described in Configuring Custom WITS in the EDR on page 24.
Page 20
Element Function WITS In All On the RMPC, use this tab to set up incoming WITS codes for all Pason computers connected to WITS devices. WITS Out RMPC On the RMPC, use this tab to set up WITS codes being sent to devices connected to the RMPC.
Page 21
Clears all your selections and returns the settings to the defaults. Table 1: WITS setup screen elements In addition to choosing individual WITS codes, the EDR provides the option of using preconfigured Full WITS or Half WITS settings to determine which WITS codes it sends.
Page 22
7. If desired, you can click in a code’s row, and enter a new WITS code for that row. Any standard WITS code that you have changed displays a Reset button. If you enter a WITS code that is already in use, click the Reset button to change back to the default Pason WITS code.
Selecting Pason Traces for the EDR to Send Starting in EDR version 14.12, the WITS setup screen includes a feature that enables you to send Pason trace data using WITS. Use this feature to send Pason traces that aren't included with the standard WITS codes.
If you need to send or receive data not listed in the table of Default Pason WITS Codes on page 32, you must set up a custom WITS code. Once a custom WITS code is set up, the EDR can receive it from any connected WITS device, but you need to follow the...
WITS code. Ensure that this code is different from the existing WITS codes. If the code you enter conflicts with a current EDR WITS code, the EDR highlights your entry in red and does not allow you to save your settings.
Page 26
Shelf life is an important selection for time sensitive data. The EDR displays the last received WITS value until the sender transmits a new value, or until it reaches the end of the shelf life period. WITS data with a long shelf life can be misleading if users don’t know the data’s age.
2. Enter the custom four digit WITS code you want to use to send the value. Use a code that’s different from the existing WITS codes. If the code you enter conflicts with a current EDR WITS code, the EDR highlights your entry in red and does not allow you to save your settings.
Menu, you can assign it a custom WITS code, which you can instruct a Pason computer to send. Follow these steps to set up a Pason computer to send a custom WITS code for a connected custom sensor: 1. Ensure that the custom sensor is connected, and assigned a name in the EDR’s Custom Calibration Menu.
32, but it’s an advanced EDR feature that you need to use with caution. Before you set up the EDR to receive WITS 01 codes, think about these important points: Contact your Pason representative for assistance before you set this up. If •...
08211780.2 082463.8 4.10 Importing and Exporting Your WITS Settings The EDR enables you to import and export saved WITS settings, for sharing via email or USB memory stick. Follow these steps to export WITS settings: 1. Select the WITS out tab of the Pason computer whose settings you want to export.
EDR can be configured to receive up to 50 additional custom WITS codes. Note: All data values sent via WITS are in float format (e.g. “####.##”). Note: When sending gamma and gamma depth values to the EDR via WITS, both values need to be in the same WITS packet. WITS EDR can...
Page 33
WITS EDR can EDR Sends in EDR Sends in Name Code Receive Full WITS Half WITS Mode Mode Party Gas 0140 Mechanical Specific Energy 0141 TotalPumpDisplacement 0142 Pump 1 total strokes 0143 Pump 2 total strokes 0144 Pump 3 total strokes...
Page 34
WITS EDR can EDR Sends in EDR Sends in Name Code Receive Full WITS Half WITS Mode Mode Available Transmission Types: Time Based, Depth Based, or Request-Response Date 0805 Time 0806 Resistivity 1 Lag Calc 0813 Resistivity 1 0816 Resistivity 2 Lag Calc...
Page 35
WITS EDR can EDR Sends in EDR Sends in Name Code Receive Full WITS Half WITS Mode Mode Record 12: Chromatograph Cycle Based Available Transmission Types: Time Based, Depth Based, or Request-Response Date 1205 Time 1206 chr Methane C1 1212...
01691234.56 01705.43 The first four digits in a packet make up the WITS code. The digits that follow the WITS code represent the measured value being sent. The WITS specification also includes the carriage return and line feed control characters, <cr><lf>, at the end of each line.
0139 is the lag depth WITS code 01391234.56 1234.56 is the measured value being sent 4.13 Sample Half WITS Data Sent by Pason A typical Half WITS packet would be as follows: && Indicates the start of a packet 1984PASON/EDR 0108136.19...
1984PASON/EDR 08210.00 08240.00 Important: Pason does not guarantee packet order or the order in which the EDR sends each channel within the packets. 4.15 Using the WITS Monitor Starting in EDR version 14.12, the EDR includes a WITS monitor (Figure 16).
Use the IP address displayed at the top of the command prompt screen to find the device on the WITS monitor screen. The EDR starts displaying the packet information in the WITS In and WITS Out boxes.
If a Pason technician needs to troubleshoot WITS communications using CommEngine log files, they can use the Port and Port Name details to identify the CommEngine to work on. Each WITS device is represented by its own CommEngine process. WITS CommEngine troubleshooting information is available to Pason personnel in KBase 1125 Debugging WITS Data Using CommEngine Log Files.
About WITS Port Pin-Outs This section contains pin-outs to guide you as you design a product interface that is compatible with the Pason system. Consult the information below if you are connecting a third-party device that uses RS232 or RS422 communications.
COMM018 RS232 Pin-Outs COMM018 provides a military connector on the third-party side. The table below lists pins and descriptions for the COMM018 pin-outs: Mil.con Pin Description 12 VDC all other pins unused Figure 18: COMM018 RS232 pin-outs RS422 Port Pin-Outs Conversion via a communications box is not required if your third-party device has RS422 communication, because RS422 communication is what the EDR accepts.