Model WS Range
Model SBI-140 Indicator
User Manual
11 January 2007
AWT35-000056 Issue B
AWT35-000056

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Salter Brecknell WS Series

  • Page 1 Model WS Range Model SBI-140 Indicator User Manual 11 January 2007 AWT35-000056 Issue B AWT35-000056...
  • Page 2 Model WS / SBI-140 Indicator User Manual...
  • Page 3 The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied. Salter Brecknell is a trading name of Avery Berkel Limited...
  • Page 4: Table Of Contents

    Model WS / SBI-140 Indicator User Manual Contents WARNINGS..............................5 Setup Instructions............................6 Desk/Wall Bracket ........................... 6 Power Supply ..........................6 Installing Batteries ........................... 7 Connecting Indicator to Platform ..................... 7 General Operating Instructions ........................8 Display............................. 8 Manual symbols..........................9 Indicator Operation ............................
  • Page 5: Warnings

    Model WS / SBI-140 Indicator User Manual WARNINGS Safe installation Safety THE EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS. Installation and maintenance of the equipment must only be carried out by trained and authorised personnel. Electrical installation The mains lead must be connected to a supply outlet with a protective earth contact. The electrical supply at the socket outlet must provide over current protection of an appropriate rating.
  • Page 6: Setup Instructions

    Model WS / SBI-140 Indicator User Manual Setup Instructions Desk/Wall Bracket By changing the angle blocks as shown below, the indicator bracket can be converted into a wall mounting bracket. Power Supply...
  • Page 7: Installing Batteries

    Model WS / SBI-140 Indicator User Manual Installing Batteries Connecting Indicator to Platform If necessary, wire the cable attached to the base as shown.
  • Page 8: General Operating Instructions

    Model WS / SBI-140 Indicator User Manual General Operating Instructions Display Function Keys Annunciators Centre of zero On/Off/Zero Net weight displayed Activate the tare Hold activated Select unit kg, lb, oz Active unit of measure Hold/Print Scale in motion...
  • Page 9: Manual Symbols

    Model WS / SBI-140 Indicator User Manual Manual symbols Short key press Multiple key press Long key press Indicator Operation Turning On and Zeroing the Indicator Turning off the Indicator...
  • Page 10: Selecting Unit Of Measure

    Model WS / SBI-140 Indicator User Manual Selecting Unit of Measure kg → lb → lb.oz. Using the Tare Removing the Tare...
  • Page 11: Hold Function - Automatic Zero On Next Weigh

    Model WS / SBI-140 Indicator User Manual Hold Function - Automatic Zero on Next Weigh HOLD HOLD HOLD HOLD HOLD HOLD Hold Function - Manual Release This function needs to be set up in Parameter P3.1 shown on page 14. HOLD HOLD HOLD...
  • Page 12: Removing Hold

    Model WS / SBI-140 Indicator User Manual Removing Hold HOLD Print Function For communications to a printer or PC, the indicator has to be set up in the following parameters P2, P4, P5 and P6. HOLD Zero >0< 3. Print Gross: 45.00kg Tare: 1.45kg...
  • Page 13: Error Messages

    Model WS / SBI-140 Indicator User Manual Error Messages Error Message Definition Required Solution Remove load before zeroing, Weight above range for calibrated 0¯ ¯ ¯ ¯: -or- zero point Recalibrate the scale. Remove load before zeroing, Weight below range for calibrated -or- 0_____: zero point...
  • Page 14: User Configuration Settings

    Model WS / SBI-140 Indicator User Manual User Configuration Settings Setup Controls Exits setup mode Saves data and move down Moves flashing digit Change flashing digits to next parameter setting 1. Entering Setup HOLD 2. Selecting parameter 3. Changing data within parameter HOLD HOLD Zero...
  • Page 15: Configuration Settings

    Model WS / SBI-140 Indicator User Manual Configuration Settings Parameter Setting Default settings in bold P1.xx P1.00 Auto shut-off timer in minutes P1.01 – P1.15 Set up time for the auto-off function P1.05 (00 = 0ff, 01-15 = time in minutes) P2.x Hold and print key functionality P2.0 = Hold...
  • Page 16: Data Commands For Bi-Directional Interface

    Model WS / SBI-140 Indicator User Manual Data Commands for Bi-directional Interface The RS232 can be set so a bi-directional connection can be established between the indicator and the host. To establish this connection, set parameter P4 to 7, so it is compatible with the NCI-SP1. Commands can then be sent from the host to the indicator using the following commands (ensure the letters entered are in CAPS) (<CR>...
  • Page 17: Display, Measurement And Service Settings

    Model WS / SBI-140 Indicator User Manual Display, Measurement and Service Settings WARNING! Any adjustment to these settings could seriously affect indicator performance. Seek advice from a service engineer before changing. Scale setup and calibration Before calibrating, the following parameter must be setup correctly: Scale resolution (500 ~ 10000) Division size...
  • Page 18 Model WS / SBI-140 Indicator User Manual Service Settings Continued Parameter Settings Default settings in bold P12.x Power up Zero range P12.0 = +1% Selects the Power up zero-point range based on the P12.1 = +2% calibration zero point. P12.2 = +5% P12.3 = +10% P12.4 = +20% P12.5 = +50%...
  • Page 19: Scale Calibration

    Model WS / SBI-140 Indicator User Manual Scale calibration Calibration can be done with 25% to 100% of full load and can be calibrated with 1 or 2 calibration points. HOLD HOLD HOLD HOLD HOLD 4. Enter in calibration weight from 25% to 100% full capacity. HOLD HOLD HOLD...
  • Page 20: Declarations Of Compliance

    The application harmonised standards are: EN50081-1 EN50082-1 A copy of the original signed declaration for this instrument is available from the UK address below. UK and Europe Salter Brecknell Weighing Products USA Salter Brecknell Weighing 1000 Armstrong Drive P.O. Box 9533, Smethwick, Fairmont West Midlands, B66 2TE.