Picture Quality Adjustments; A Board Adjustment After Ic003 (Memory) Replacement - Sony TRINITRON KV-HF51P50 Service Manual

Trinitron color tv
Table of Contents

Advertisement

KV-HF51P50/XF21M80/XF21M83/XF21N90/XF51M65
RM-952
RM-952

4-3. PICTURE QUALITY ADJUSTMENTS

SUB COLOR ADJUSTMENT
1. Input a PAL color-bar.
2. Set to the following condition:
PICTURE 100%, BRIGHTNESS 50%, COLOR 50%
3. Connect an oscilloscope to pin 1 (B OUT) of CN305, A board.
4. Set to Service Mode and select SAJ 3 'SCL' with 1 and 4 of
the commander then adjust to VB2=VB3=VB4 with 3 and
6.
[MUTING]
5. Press
6. Adjust SAJ 3 'SCL' as step 2 to 5 when receiving NTSC color-
bar.
VB1 VB2
SUB HUE ADJUSTMENT
1. Select Video 1.
2. Input a NTSC color-bar, video into Video 1.
3. Set the following condition:
PICTURE 100%, BRIGHTNESS 50%, COLOR 50%
4. Connect an oscilloscope to pin 1 (B OUT) of CN305, A board.
5. Select SAJ 1 'SHU' with 1 and 4 of the commander by set-
ting to Service Mode and adjust to VB1=VB2=VB3=VB4 with
3 and 6.
VB1 VB2
VB1 = VB2 = VB3 = VB4
[MUTING]
6. Press
RM-952
RM-915
- of the commander to write the data.
VB3 VB4
VB2 = VB3 = VB4
VB3 VB4
- of the commander to write the data.
RM-952
BELL FILTER ADJUSTMENT
1. Input SECAM color-bar signal.
2. Connect the dual-trace oscilloscope to the pin 9 (R-Y) of
CN303 (not mounted).
3. Adjust SERVICE MODE, ITEMS 'SBF' as shown below.
4-4. A BOARD ADJUSTMENT AFTER IC003
(MEMORY) REPLACEMENT
When replacing IC003 (MEMORY), be sure to change IC001 (µ-
COM) to the following new IC at the same time.
IC001(µ-CON):CXP86449-614S (KV-XF21M80(ME))
1. Enter to Service Mode.M
2. Press commander buttons 5 and - (Data Initialize), and 2
and - (Data Copy) to initialize the data.
3. Call each item number and check if the respective screen shows
the normal picture.
In cases where items are not well adjusted, rectify the items
with fine adjustment.
Write the data per each item number (
4. Select item numbers "OPB0" (OP1), "OPB1" (OP2) and
"OPB2" (OP3) and respectively set the bit per model with
command buttons 3 and 6.
5. Press commander buttons 8 and - (Test Normal) to return
to the data that was set on the shipment from the factory.
(This will also cancel Service Mode.)
– 64 –
CXP86449-615S (Except KV-XF21M80(ME)
/XF21N90)
CXP86449-618S (KV-XF21N90)
[MUTING]
+-).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents