Heavy-duty autoranging digital multimeter with bluetooth mobile app and nist-traceable calibration (25 pages)
Summary of Contents for Digi-Sense 20250-66
Page 1
User Manual Digital IR Multimeter with Bluetooth Mobile App and ® NIST-Traceable Calibration Model 20250-66 THE STANDARD IN PRECISION MEASUREMENT...
Introduction The Digi-Sense Digital IR Multimeter (Model 20250-66) is Bluetooth enabled, allowing for ® wireless communication with any Android and iOS devices using the free D/S T-View app. ™ ® This app turns your device into a real-time data monitoring system that allows you to review, evaluate, modify and transfer the data collected to email or text.
Page 3
Safety This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter. This WARNING symbol indicates a potentially hazardous situation, which if not WARNING avoided, could result in death or serious injury.
Page 4
Description and reference guide Front description 1. NCV detector area 2. LCD 3. Navigation/Menu buttons 4. MODE button 5. RANGE button 6. Rotary function switch 7. Positive (+) probe input jack for A (current) 8. Positive (+) probe input jack for mA (current) 9.
Page 5
• Physical buttons: Freezes the present reading in the display and allows display to be saved. HOLD Also wake up for APO. MODE Press the MODE key to switch the functions. RANGE Press the RANGE key to manual range. Enter function of the menu selects. Press the IR key to switch DMM MODE and IR+DMM MODE.
Page 6
Understanding the Rotary Switch AC voltage measurements DC and AC+DC voltage measurements HZ % Frequency and Duty measurements Ω Resistance, Diode test, Capacitance and Continuity • measurements K Temp Temperature measurements AC, DC and AC+DC amps measurements AC, DC and AC+DC milliamps measurements AC, DC and AC+DC microampere measurements µA up to 6,000 μA...
• Set the function switch to the VAC position. • Insert the black test lead banana plug into the negative COM jack. Insert red test lead banana plug into the positive V jack. • Read the voltage in the main display. Frequency Measurements •...
Capacitance Measurements WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords. • Set the rotary function switch to the Ω CAP ) position.
Page 9
• For current measurements up to 6000μA AC, set the function switch to the yellow μA position and insert the red test lead banana plug into the μA/mA jack. • For current measurements up to 600mA AC, set the function switch to the yellow mA position and insert the red test lead banana plug into the μA/mA jack.
Page 10
Capturing Minimum and Maximum Values The MAX MIN Record mode captures minimum and maximum input values. When the input goes below the recorded minimum value or above the recorded maximum value, the meter beeps and records the new value. This mode is for capturing intermittent readings, recording minimum and maximum readings unattended, or recording readings while equipment operation precludes watching the meter.
Page 11
Thermal imager and DMM Operation Thermal imager basics In the Thermal imaging and DMM mode user can measure a targeted surface’s temperature and use Multimeter at the same time. The measured result will display under the thermal image. • Press the red “IR” button to open the Thermal Imager. In the image shown the thermal image is set to color palette IRON.
Page 12
The display will show the temperature measurement in the upper left hand corner for the targeted area along with the currently selected emissivity value. In the Thermal imaging mode, the laser pointer and display cross hairs can be used to assist in targeting.
• Capturing Peak Values on IR+DMM mode 1. To activate the peak mode, press the soft key labeled , and display Peak max value. 2. If the Meter is already in the peak function, then press the key to display Peak min value, then Press the key to display current measurement value.
Language • Press RIGHT/MENU button to enter language menu. Three options are available: Simplified Chinese, Traditional Chinese and English. Use UP/DOWN button to select language and use RIGHT/MENU button to set selected language to be valid. Common Press RIGHT/MENU button to enter common menu. Five options are available: Beep, Bluetooth, Laser, Brightness and Auto Off.
Page 15
Photo Press RIGHT/MENU button to enter photo menu. Two options are available: Photo Review and Delete Photo. • Photo Review: press RIGHT/MENU button to enter image browser function, and exit settings menus immediately. • Delete Photo: After pressing RIGHT/MENU button dialog box will be displayed as shown at right.
• In Record Menu. Press the Button 5 or 6 key to select Start record Item. Press the button 4. Enter Save Record Measurement (Fig 6). In Save Record Measurement, press the Button 4 to stop record. Press the Button 5 Save. •...
Technical specifications Technical characteristics • Thermal imager Field of view (FOV) / Minimum focus distance 21° x 21°/ 0.5m Spatial resolution (IFOV) 4.53mrad IR resolution 80 × 80 pixels Thermal sensitivity / NETD < 0.1°C @ +30°C (+86°F) / 100 mK Image frequency 50 Hz Focus mode...
Page 18
• AC TRMS Current Range Resolution Accuracy Protection against overcharge 600.0 μA 0.1 μA 6000 μA 1 μA ±(1.2% reading + 5 digits) Quick fuse 800mA/1000V 60.00mA 0.01mA 600.0mA 0.1mA 10.00A 0.01A ±(1.5% reading + 8 digits) Quick fuse 10A/1000V (*) Accuracy specified from 5% to 100% of the measuring range, sine wave.
Page 19
• Duty Cycle Range Resolution Accuracy 5.0% to 95.0% 0.1% ±(1.2% reading + 2 digits) Pulse frequency range: 40 Hz to 10k Hz, Pulse amplitude: ±5V (100 μs to 100ms) • Capacity Range Resolution Accuracy Protection against overcharge 60.00 nF 0.01 nF ±(1.5% reading + 20dgt) 600.0 nF...
Page 20
• Reference standards Safety: IEC/EN61010-1 EMC: IEC/EN 61326-1 Insulation: double insulation Pollution level: Overvoltage category: AT IV 600V, CAT III 1000V Max operating altitude: 6562 ft (2000 m) • General characteristics Mechanical characteristics Size (L x W x H): 7 x 3 x 2 in (175 x 85 x 55 cm) Weight (batteries included): 19 oz (540g) •...
Environmental conditions for use Reference temperature: 18°C to 28°C (64°F to 82°F) Operating temperature: 5°C to 40°C (41°F to 104°F) Allowable relative humidity: <80% RH Storage temperature: -20° to 60°C (- 4°F to 140°F) Storage humidity: <80% RH...
Page 22
Maintenance, Recalibration, and Repair • Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners: only use clean water. • The product must be repaired by the manufacturer.
Page 23
It is recommended that Digi-Sense products are calibrated annually to ensure proper function and accurate measurements; however, your quality system or regulatory body may require more frequent calibrations. To schedule your recalibration, please contact InnoCal, an ISO 17025 calibration laboratory accredited by A2LA.
Page 24
For Product and Ordering Information, Contact: Toll-Free: 1-800-323-4340 Phone: 1-847-549-7600 Fax: 1-847-247-2929 ColeParmer.com/Digi-Sense 1065DGMAN_20250-66 Manual Part No. 00102-02...
Need help?
Do you have a question about the 20250-66 and is the answer not in the manual?
Questions and answers