REMA Technology Shanghai Co. Ltd REMA Lipprandt GmbH & Co. KG REMA USA, LLC No. 1590 Songfu Road Spichernstraße 11 101 Park Place Court Qingpu Industry Zone 53175 Bonn Greenville, SC 29607 201706 Shanghai Tel.: +49 228 38204-0 Tel.: +1 864 655-8981;...
Page 2
DIN Standard 43589 for both mechanical and electrical durability. The three traditional sizes of power connectors are based upon the amperage requirements: DIN 80 A, DIN 160 A, DIN 320 A To meet the demands of newer high-current applications, including “fast charging”, REMA has developed a larger capacity DIN 640 A ®...
Connect auxiliary contacts (4a) with the supply lines and insert into the contact receiving part (1). Crimp wire ends and contacts with REMA pressing tools (refer to REMA tool catalogue). Caution: Page 5 of 13 The crimp inserts must be selected in accordance with the wire diameter.
Web: www.rema-bonn.de Web: www.rema-ev.com Web: www.rema-shanghai.com REMA – TECHNICAL INFORMATION Dimensions Housing DIN 80, DIN 160 and DIN 320 Connectors Plug Dimension DIN 80, 160, 320 Connectors Socket Dimension DIN 80, 160, 320 Housing Front View and Assignment Auxiliary Contacts...
Page 7
Web: www.rema-bonn.de Web: www.rema-ev.com Web: www.rema-shanghai.com REMA – TECHNICAL INFORMATION Dimensions of Contact Pin and Contact Bushing of DIN 80, DIN 160 and DIN 320 Main Contact PIN Main Contact Bushing ain Contact Dimensions Cross section / sqmm DIN 80...
Pilot Contact Adapter for Plug Pilot Bushing Pilot Pin Auxiliary Bushing Auxiliary Pin Dimensions of Auxiliary and Pilot Contacts of DIN 80, DIN 160 and DIN 320 *Image similar Pilot and Auxiliary Contact Dimensions Pilot or Auxiliary DIN 80 DIN 160...
Web: www.rema-bonn.de Web: www.rema-ev.com Web: www.rema-shanghai.com REMA – TECHNICAL INFORMATION Optional Handles, Screwed or Moulded of DIN 80, DIN 160 and DIN 320 Handles: Screwed or Moulded Screwed Version for Socket and Plug Moulded Version for Sockets only Screwed Handle...
To help prevent a mismatch REMA® has developed a special coding system where only matching batteries and chargers can be connected. Nevertheless the usage of the wet/dry coding pin allows the connection between the electric motor and both types of batteries.
Air introduced into the bottom of the battery cell creates air bubbles that circulate and cool the electrolyte. REMA has developed optional adapters which can be mounted in the connector housings thus creating a „two-in-one“-connection: electrical energy and air.