VK SERIES GENERAL PUMP A member of the Interpump Group 1. INTRODUCTION This manual describes the use and maintenance instructions of the VK pump, and should be carefully read and understood before using the pump. Correct use and adequate maintenance will guarantee the pumps trouble-free operation for a long time. General Pump declines any responsibility for damage caused by misuse or the non-observance of the instructions indicated in this manual.
VK SERIES GENERAL PUMP A member of the Interpump Group 3. SAFETY 3.1 General Safety Indications Improper use of pumps and high pressure systems, and/or failure to observe the installation and maintenance instructions may cause serious injury to people and/or damage to property. Anyone assembling or using high pressure systems must possess the necessary competence to do so, should be aware of the characteristics of the components assembled/used, and must take all precautions necessary to ensure maximum safety in any operating condition.
VK SERIES GENERAL PUMP A member of the Interpump Group Note: appropriate clothing will effectively protect against water spray, but it may not offer adequate protection against the direct impact of water jets or sprays from a close distance. Some circumstances may require further protection. 3.
VK SERIES GENERAL PUMP A member of the Interpump Group 5. TECHNICAL FEATURES FLOW RATE PRESSURE POWER MODEL Version without 1200 reduction gear VK12 20.4 21750 1500 1500 Version with reduction 1800 gear 2200 Version without 1200 reduction gear VK14...
VK SERIES GENERAL PUMP A member of the Interpump Group 6. DIMENSIONS AND WEIGHT For dimensions and weight of reduction gear unit version, please refer to fig. 2. For dimensions and weight of version without reduction gear unit, please refer to fig. 2a. Weight: 212 Lbs./96 Kg.
VK SERIES GENERAL PUMP A member of the Interpump Group 7.2 Max Flow Rate and Pressure Values The performance values indicated in the catalog refer to the maximum performance of the pump. Regardless of the power used, pressure and maximum RPM values indicated on the plate may not be exceeded unless expressly authorized by the Customer Service Department.
Page 9
VK SERIES GENERAL PUMP A member of the Interpump Group In any case, oil must be changed at least once a year since it may deteriorate by oxidation. For room temperatures that differ from that mentioned earlier, follow the indications contained in the diagram below, keeping in mind that the oil must have a minimum viscosity of 180 cSt.
VK SERIES GENERAL PUMP A member of the Interpump Group 8. PORTS AND CONNECTIONS VK Series pumps are equipped with (see fig. 4): 1. 2 inlet ports “IN”, 3/4” BSP-F. The line can be connected to either of the two inlet ports; the ones not being used must be hermetically sealed. 2.
VK SERIES GENERAL PUMP A member of the Interpump Group 9. PUMP INSTALLATION 9.1 Installation The pump must be fixed horizontally using the M16x1.5 threaded support feet. Tighten the screws with a torque of 155 Ft.Lb. (210 Nm). The base must be perfectly flat and rigid enough as not to allow bending or misalignment on the pump coupling axis/transmission due to torque transmitted during operation.
VK SERIES GENERAL PUMP A member of the Interpump Group 9.2 Direction of rotation The PTO rotation is indicated by an arrow located on the casings. From a position facing the pump head, the rotation direction will be: • As per fig. 6 for versions with a reduction gear •...
VK SERIES GENERAL PUMP A member of the Interpump Group 9.4 Hydraulic Connections To isolate the system from the vibrations produced by the pump, we recommend building the first section of hose adjacent to the pump (for both intake and outlet) with flixible hose. The solidity of the intake section must be enough to prevent deformation caused by the depression produced by the pump.
VK SERIES GENERAL PUMP A member of the Interpump Group 9.7 Filtration The level of filtration permitted for this series of pumps must be maximum 20 µm (micron). Normally this is obtained by a battery of at least three filters, positioned as shown in fig. 7. The filters must be installed as close as possible to the pump.
VK SERIES GENERAL PUMP A member of the Interpump Group 9.9 Internal Diameter of the Hose Line To determine the internal diameter of the hose, please refer to the following diagram. Inlet Hose With a flow rate of ~5.3 GPM (20 l/mn) and water speed of 0.5 m/sec. The diagram line that connects the two scales intersects the central scale, indicating the diameters, at a value of ~ 1.1 inch (28 mm).
VK SERIES GENERAL PUMP A member of the Interpump Group 9.10 V-belt Transmissions V-belt transmission is only allowed on versions without a reduction gear. For this pump model, we recommend use of 4 XPB belts (16.5 x 13 serrated). Use an XPC profile only for long durations.
VK SERIES GENERAL PUMP A member of the Interpump Group 9.11 Transmission Definition To prevent irregular radial loads on the shaft and the relative bearing, follow these directions: a) Use pulleys with v-belts with the size of the groove required/recommended by the manufacturer of belt used. In the absence or directions, follow fig.
VK SERIES GENERAL PUMP A member of the Interpump Group b) Use high performance belts - for example XPB instead of SPB - as a lower quality of belts for the same transmitted power may be necessary and a consequent shorter resulting distance compared to the shaft shoulder (PTO), “a”...
Page 19
VK SERIES GENERAL PUMP A member of the Interpump Group Conclusion: with a dynamometer, loading the belt branch with 75 N as indicated in fig. 14, a “te” bend of aproximately 10.8 mm is obtained. Note : Unless otherwise stated by the supplier of the belts, control of proper pull and its relative re-tensioning should be performed after no less than 30 minutes of motion necessary for the normal asjustment of the belts.
VK SERIES GENERAL PUMP A member of the Interpump Group 10. START-UP AND OPERATION 10.1 Preliminary Inspections Before Start-up Be sure that: The inlet line is connected and up to pressure (see Chapter 9) the pump must NEVER run dry. 1.
VK SERIES GENERAL PUMP A member of the Interpump Group 10.3 Cooling Circuit Seal Packing During operation, some water from the cooling circuit seal packings will be discharged from port 1 (fig. 9). The drainage from this circuit must be redirected to the inlet line upstream of the booster pump (fig. 9) or to the collection tank. 11.
VK SERIES GENERAL PUMP A member of the Interpump Group 12. PUMP STORAGE 12.1 Inactivity for Lengthly Periods If the pump is started for the first time after a long period of inactivity, before putting it into operation check the oil level, inspect the valves as indicated in Chapter 10, and then follow the prescribed startup procedures.
VK SERIES GENERAL PUMP A member of the Interpump Group 15. TROUBLESHOOTING The pump does not produce any noise at start-up: • The pump is not primed and is running dry • There is no water in the inlet line •...
A member of the Interpump Group 17. MAINTENANCE LOG HOURS & DATE OIL CHANGE GREASE PACKING REPLACEMENT PLUNGER REPLACEMENT VALVE REPLACEMENT GP Companies, Inc. 1174 Northland Drive Mendota Heights, MN 55120 Phone: 651.686.2199 Fax: 800.535.1745 Ref 300837 Rev.C www.generalpump.com email: sales@gpcompanies.com 04-16 Page 26...