new standard lImIted parts & labor warranty
Peerless products are guaranteed against manufacturing defects for one
year from date of installation for parts and labor. All SC Series ovens qualify
for two years parts and labor. Proper start-up procedures must be followed
and warranty card submitted to activate either warranty. If warranty is not
activated, parts will be covered until the term of the warranty expires but labor
will not be covered. Excluded from this warranty are any claims related to
items that should have been performed at the time of installation such as:
improper utility connections, poor methods of venting, checking gas pressure
and calibration of controls, also excluded are normal maintenance items such
Conforms to
as adjustments to pilots, burners and cleaning related issues.
AnSi/UL Std. 197
and
When making a claim for warranty service, during a claim inspection by
Cert. to CAn/CSA Std.
Peerless or its service representative, it is determined that the equipment
C22.2 no. 109
has not been used in an appropriate manner, has been modified, or has not
been properly maintained, or has been subject to misuse, abuse, has not
been properly installed / calibrated* or misapplication, neglect, accident,
damage during transit, fire, flood, riot, or act of God, then this warranty shall
be VOID.
* Warranty terms are VOID if instructions provided with equipment are not
followed.
If replacements parts are needed,
be sure to give the model number when ordering, including prefix and suffix letters.
Please retain this manual for future reference
Model #
Serial #
P.O. Box 859
Sandusky, Ohio 44870
(419) 625-4514
FAX 625-4597
www.Peerlessovens.com
office@peerlessovens.com

Advertisement

Table of Contents
loading

Summary of Contents for PEERLESS VL30

  • Page 1 CE61 CE121 CE131 B, p & i MODELS • VEntLESS VL30 & VL50 new standard lImIted parts & labor warranty Peerless products are guaranteed against manufacturing defects for one year from date of installation for parts and labor. All SC Series ovens qualify for two years parts and labor.
  • Page 2: Table Of Contents

    table of contents Congratulations ........1 Set Up Instructions (all models).
  • Page 3: Congratulations

    Limited Warranty will be rendered void. If in doubt, call Peerless for the nearest Service Agency. Retain this manual for future use.
  • Page 4: Set Up Instructions (All Models)

    Check to be sure owners manual, handles and legs and brackets (required for stacked units) are packed inside. Check unit for possible damage during transit. Notify Peerless immediately if any Figure 1 damage is found. 2. place oven in its permanent location.
  • Page 5: Ce Series Operation Instructions

    ce serIes operatInG InstructIons burn off Please note: For the first hour of operation the “burn off” will occur. The unit will smoke considerable during this period. Burn off is oil residue and insulation break in. Allow for good ventilation during this time. There is no danger if you follow these directions and proceed with care and caution.
  • Page 6: Ce Series Troubleshooting

    ce serIes troubleshootInG GuIde problem cause remedy Unit on, but will not heat One or more elements not working Replace bad elements Loss of one or more legs of Call electrician to power source restore power Bad solid state relay (SSR) Replace Unit power is off Toggle switch off...
  • Page 7: Ce Series Suggested Maintenance

    ce serIes suGGested maIntenance daIly Wash all exposed cleanable areas monthly Clean around lower front and fan for accumulation of lint, dirt, or grease. oven InterIor The interior of your unit is aluminized steel and must be treated with care. Clean by using mild detergents and a brillo type pad.
  • Page 8: Parts Replacements Instructions

    ce serIes parts replacement InstructIons controller Disconnect from power Remove screws on lower front to access control Remove controller and mount replacement Carefully replace wires to the proper terminals solId state relay Disconnect from power Remove back cover Remove relay and mount replacement Carefully replace wires to the proper terminals calrod elements Disconnect from power...
  • Page 9: Parts List Ce 131 Ie

    CEI1326 hinge Pin Assembly (Sold in Pairs!) $110.00 CEI1327 1/2" Pizza Decks (3 required) $125.00 CEI1328 Lower heater holder and Baffle $105.00 CEI1329 Peerless Nameplate $22.00 CEI1330 Instruction Manual $15.00 CEI1331 Back Cover $55.00 CEI1332 4" Legs(set of 4) $125.00...
  • Page 10: Parts List Ceie Electric Series B, P Models

    28" Legs (Set of 4) Black 295.00 CEI26 1" Pizza Deck (1- 2Pcs. Deck) P models 675.00 CEI27 Steel Deck B Models 295.00 CEI28 Peerless Nameplate 22.00 CEI29 Stainless Steel Front Trim 85.00 CEI30 Instruction Manual 15.00 CEI31 high Limit 95.00...
  • Page 11: Parts List B121Ie

    BEI121-16 hinge Pin Assembly (Sold in pairs!) 110.00 BEI121-17 1/2" Pizza Decks (2 required) 125.00 BEI121-18 Lower heater holder and Baffle 105.00 BEI121-19 Peerless Nameplate 22.00 BEI121-20 Instruction Manual 15.00 BEI121-21 Back Cover 55.00 BEI121-22 4" Legs(set of 4) 125.00...
  • Page 12: Dtb Temperature Controller

    dtb temperature controller...
  • Page 14: Wiring Diagram Ce61 Single Phase

    ce61 b, I, & p 1 phase 220v wIrInG dIaGram T.B. LINE h.L. L.S. F.S. 15 10 5 14 9 CLARoSTAT 13 8 12 7 11 6 F.h. F.h. 2 KOLMS CONT. 3.90K RESISTOR 10 PC RELAY RELAY T.B. TERMINAL BLOCK H.L.
  • Page 15: Wiring Diagram Ce61 Three Phase

    ce61 b, I & p 3 phase wIrInG dIaGram WhITE BLACK h.L. 15 10 5 14 9 L.S. F .S. F.h. F.h. 2 KOLMS CONTROLLER 9-30-15...
  • Page 16: Wiring Diagram Ce41/51 Single Phase

    ce41 - 51 p, b & I 220v 1 phase wIrInG dIaGram T.B. A2 A1 h.L. 15 10 5 14 9 T.S. 13 8 F.h. F.h. 12 7 11 6 CONTROLLER F.L. F.S. ThERMOCOUPLE 10-27-15...
  • Page 17: Wiring Diagram Ce41/51 Three Phase

    ce 41 - 51 b, I & p 220v 3 phase wIrInG dIaGram LINE V T.B. h.L. 15 10 5 14 9 T.S. 13 8 F.h. F.h. 12 7 11 6 CONTROLLER F.L. F.S. ThERMOCOUPLE 10-2-15...
  • Page 18: Wiring Diagram Ce131 Single Phase

    ce131 1 phase 220v wIrInG dIaGram LINE V T.B. A2 A1 h.L. 15 10 5 14 9 T.S. 13 8 12 7 11 6 F.h. F.h. CONTROLLER F.S. F.L. ThERMOCOUPLE RELAY T.B. TERMINAL BLOCK H.L. HiGH LiMiT F.h. FUSE hOLDER T.S.
  • Page 19: Wiring Diagram Ce131 Three Phase

    ce131 220v 3 phase wIrInG dIaGram LINE T.B. h.L. 15 10 5 14 9 13 8 T.S. 12 7 11 6 F.h. F.h. CONTROLLER F.S. F.L. ThERMOCOUPLE 9-11-15...
  • Page 20: Wiring Diagram B121

    b121 220v wIrInG dIaGram for 4 heatInG elements h.L. 15 10 5 14 9 T.S. 13 8 F.h. F.h. 12 7 11 6 CONTROLLER F.S. F.L. ThERMOCOUPLE 10-29-15...
  • Page 21: Ventless Models Operating Instructions

    / vl50 wIrInG The Peerless oven has been prewired to your hood at the factory. have a qualified electrician hook up the wires that leave the electrical box on the hood and install them on L1 and L3 on the terminal block of the oven.
  • Page 22: Ventless Models Safety Precautions

    / vl50 For your safety, please observe the following safety precautions when operating or servicing your Peerless equipment. Read the following important safety information to avoid personal injury and/or damage to the equipment. cautIon / warnInG...
  • Page 23 / vl50 cautIon Ensure the unit is position to maintain 18” clear above the hood body (excluding dampers, and 18” clear to the left (side with the pull station). 0” to the read and 0” to the right.
  • Page 24: Ventless Models Maintenance

    / vl50 Maintenance is necessary for your Ventless hood System to maintain the unit’s efficiency over time. Quarterly hood cleanInG During cleaning of the unit: DO NOT steam clean. DO NOT use products containing chlorine.
  • Page 25: Ventless Models Guidelines

    GuIdelInes models vl30 / vl50 According to the NFPA, dirty hoods are the major cause of fire in commercial kitchens. Following these simple recommended guidelines can prevent that from happening. hood - daily (recommended) • inspect grease filters checking for accumulated grease, clean if necessary (instructions state below).
  • Page 26 / vl50 exhaust fan - monthly (recommended) • if belt drive system, check condition of drive belts for proper tension. Adjust belt tension if necessary; belts tend to stretch during break in period. • check belts for fraying and wear, replace when necessary.