Controls separately, that communicates in radio-frequency with the CH115RF The CH115RF is powered by two AA 15V batteries and is suitable to remotely control a relay The ther- mostat measures the room temperature through an internal probe and keeps the “set point” by controlling...
First of all, make sure that the self-learning procedure has been performed yet (page 8); moreover, verify that both the CH115RF and the CH173D are 30 me- ters far from each other at the most In fact, this dis- tance represents the free air maximum range for the...
Summer / Winter Selection Operating modes To switch from Winter operation (ie: heating system) The CH115RF thermostat features three different to Summer operation (ie: air-conditioning system), manual operating modes: Comfort, Economy and the and vice versa, press the 3+4 key combination simul-...
“Economy” operating mode “OFF” Function (OFF / Antifreeze) With the “economy” operating mode (key 3, Economy The “OFF” function is obtained by pressing key 4: in symbol), the thermostat regulates the heating or air- this case the thermostat performs thermoregulation conditioning system operation in order to keep always on the antifreeze temperature set the same economy temperature set...
Page 7
Configuration menu By means of a pointed object, press the reset button while simultaneously pressing the button When the display shows P01 (first parameter), re- lease the button The configuration parameters are represented on the display by an index: P01, P02 … Scroll through the indexes of the parameters by pressing the buttons Changing a parameter...
Page 8
Parameter Default value Values Display modes 1 = ambient Temp display 2 = set point display Displayed temperature value correction 00°C +/- 4°C (pitch 01°C) Lower limit of the winter set point 20°C 20°C … 400°C (pitch 10°C) Upper limit of the winter set point 400°C 20°C …...
Page 9
Upper part radio address (MSB) Progressive assigned 0 … 255 in production If there are conflicts for multiple CH115RF, allows changing the radio address assigned in production Performing a reset by pressing the keys “ar- row up”+”OFF”, restores the address assig-...
Maintenance Fastening the base The thermostat comes with a base suitable for wall To clean the thermostat use just a soft cotton cloth mounting or for flush-mounting in three-module (503) and no detergent rectangular or round boxes Installation BATTERY COMPARTMENT Caution: The thermostat shall be installed by quali- fied personnel only, in compliance with the current SCREWS...
To ensure correct operation the base shall be installed at about 1.5 meters above the floor level and far from In order for the CH115RF and the CH173D to com- heat sources (eg: direct sunlight, etc), doors and municate correctly, a “self-learning” procedure shall...
Page 12
Technical data Micro-disconnection Power supply Two AA batteries (15V) Pollution degree Outputs (CH115RF) RF module Impulse voltage 4000V Insulation Double Compliant with the follow- 2006/95/CE , 2004/108/CE, Protection IP20 ing EC Directives 1993/68/CE Setting storage Non-volatile memory Compliant with the follow- R&TTE EN 300 220-3, EN...
Page 15
DISPOSAL OF PRODUCTS The crossed out wheeled dust bin symbol indicates that products must be collected and disposed of separately from household waste Integrated batteries and accumulators can be disposed of with the product They will be separated at the recycling centres The black bar indicates that the product was placed on the market after August 13, 2005 By participating in separate collection of products and batteries, you will help to assure the proper disposal of products and batteries and thus help to prevent potential negative consequences for the environment and human health For more detailed information...
Page 16
Fantini Cosmi s.p.a. Via dell’osio, 6 20090 Caleppio di settala, milano - italY tel. +39 02 956821 Fax +39 02 95307006 info@fantinicosmi.it EXPoRt DEPaRtmEnt Ph +39 02 95682229 export@fantinicosmi.it www.fantinicosmi.com...