1. MODEL NUMBERING AND NAMEPLATE INFORMATION
1.1 Model numbering
VPC/VPS 5
16 SQQE
1.2 Nameplate format
1
2
3
5
7
GPM
9
11
1. Pump Type – Seal Type
2. Pump Model
3. Frequency
4. Rated Power
5. Speed
6. Maximum Head
7. Capacity
8. Head Range
9. Maximum Operating Pressure
10. Rotating Direction
11. Serial Number
2. HANDLING
Read these instructions carefully before beginning installation.
Lift and handle these pumps carefully. VPC & VPS series are
vertical multi-stage non-self priming pumps coupled with
standard electric motors. This manual applies to standard ver-
sion pumps and for standard applications. Contact your supplier
or the factory for information about special pump versions and
applications.
3. APPLICATIONS
VPC & VPS series in-line pumps booster pumps are designed
for a wide range of applications in various industries – for water
treatment, water boosting, water supply, cooling, cleaning, etc.
3.1 Pumped liquids
The pumps are designed for use with clean, viscous and non-
explosive liquids that do not contain abrasive matter.
INSTALLATION AND OPERATING INSTRUCTIONS
Code for
Shaft Seal
Number of Stages
Nominal Flow
Type Ranges
4
6
ft
8
ft
10
psi/˚F
VPC-VPS
Vertical Multistage Centrifugal In-line
These pumps are not designed to be used
with abrasive, solid containing, explosive
and corrosive liquids.
For special application, please contact
your supplier or the factory.
4. TECHNICAL DATA
4.1 Temperatures
Ambient temperature: 32 F to +104 F
If ambient temperatures are above +104° F
or if the pump is located at elevations more
than 3,000 feet above sea level, the motor's
output must be decreased to compensate
for less effective cooling, and may have to
be replaced with a stronger motor.
Liquid temperature: -5 F to +248 F
4.2 Maximum operating pressure
Refer to page 8
4.3 Minimum inlet pressure-NPSH
To avoid cavitation, make sure that there is a minimum pressure
on the suction side of the pump.
NPSHA: Net Positive Suction head Available
The net positive suction head available is a function of the pump
suction system.
NPSHR: Net Positive Suction head required
The net positive suction head required is a function of the pump
design at the operating point on the pump performance curve.
Pumps Spare Parts

Advertisement

loading

Summary of Contents for Pearl VPS 1

  • Page 1 VPC-VPS Vertical Multistage Centrifugal In-line Pumps Spare Parts INSTALLATION AND OPERATING INSTRUCTIONS 1. MODEL NUMBERING AND NAMEPLATE INFORMATION 1.1 Model numbering VPC/VPS 5 16 SQQE Code for Shaft Seal Number of Stages Nominal Flow Type Ranges 1.2 Nameplate format These pumps are not designed to be used with abrasive, solid containing, explosive and corrosive liquids.
  • Page 2: Installation

    4.6 Electrical data NPSHA=Ha-Hs-Hf-Hv-Hst (in meters head) See the motor nameplate. Ha: Barometric pressure. (That can be set to 15 psi.) Hs: Suction lift. Make sure that the supply voltages, phase Hf: Friction loss in suction pipe. and frequencies correspond to the motor Hv = KT+KH: Vapor pressure specifications.
  • Page 3: Electrical Connection

    Size pump for correct head. Place the intake of the suction pipe so that the intake is always submerged to prevent entry of air. Install a compound gauge at the pump suction and a pressure gauge at the pump discharge. Pos.
  • Page 4: Maintenance

    8. MAINTENANCE 7.2 Others (Only for VPC, VPS 1, 3, 5 series) Before starting maintenance work on the • For these pumps, it is advisable to open the bypass valve pump, the motor, or other parts of the system, during start-up. The bypass valve connects the suction...
  • Page 5: Troubleshooting

    9. TROUBLESHOOTING PROBLEM POSSIBLE CAUSE REMEDY Supply failure or no power supply. Check connections or restart the power supply. Main contacts in motor starter are not making Reconnect or replace contacts or magnetic coil. contact or the motor coils are defective Pump or auxiliary circuits protection fuses Replace fuses.
  • Page 6 ... troubleshooting cont. PROBLEM POSSIBLE CAUSE REMEDY Pump is not primed with liquid. Fill the pump with the liquid to be pumped. The pump, suction or discharge pipes are Clean the pump, suction or discharge pipe. blocked by solids in the liquid being pumped. The foot or check valve is blocked or has Replace the foot or check valve.
  • Page 7 Type [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] VPC 1 1/1 ¼ 3.94 5.55 7.09 8.66 0.55 VPS 1 1/1 ¼ 3.94 5.91 7.09 8.66 0.55 VPC 3 1/1 ¼ 3.94 5.55 7.09 8.66 0.55 VPS 3 1/1 ¼...
  • Page 8 VPC-VPS 1, 3, 5 coupling adjustments VPC-VPS 10, 15, 20 Coupling adjustments VPC-VPS 32, 45, 64, 90 Coupling adjustments WA TER SYSTEMS PD WATER SYSTEMS - 3000 W. 16 Ave. Miami, FL 33012. TEL: (954) 474 9090 FAX: (954) 889 0413 www.pdwatersystems.com |...

This manual is also suitable for:

Vpc 1Vps seriesVpc seriesVpc 3Vps 3Vps 5 ... Show all